Intel® Server Board S5500WB TPS
Configuration Jumpers
Revision 1.9
Intel order number E53971-008
47
Table 17: Server Board Jumpers (J1B5, J1C2, J1C3, J1B4, J6A3, J6A2)
Jumper Name
Jumper Position
Mode of
Operation
Note
J1B5: BMC Force
Update jumper
1-2
Normal
IBMC GPIO[1] is pulled HIGH. Default position.
2-3
Update
IBMC GPIO[1] is pulled LOW.
J1C2: Password Clear
1-2
Normal
ICH10R INTRUDER# pin is pulled HIGH. Default
position.
2-3
Clear Password
ICH10R INTRUDER# pin is pulled LOW.
J1C3: BIOS Recovery
Mode
1-2
Normal
ICH10R GPIO [55] is pulled HIGH. Default
position.
2-3
Recovery
ICH10R GPIO [55] is pulled LOW.
J1B4: CMOS Clear
1-2
Normal
ICH10R RTCRST# pin is pulled HIGH. Default
position.
2-3
Clear CMOS
Settings
ICH10R RTCRST# pin is pulled LOW.
J6A3: Video Master
1-2
Internal
Internal connector will override if both connectors
are used.
2-3
External
External connector will override if both
connectors are used.
J7A2: ME Firmware
Force Update
1-2
Disabled
Default
2-3
Enabled
J6A2: Serial Interface
1
– 2
DCD to DTR
Data Carrier Detect
3
– 4
DSR to DTR
Data Set Ready
6.1.1
Force IBMC Update (J1B5)
When performing a standard BMC firmware update procedure, the update utility places the
BMC into an update mode, allowing the firmware to load safely onto the flash device. In the
unlikely event the BMC firmware update process fails due to the BMC not being in the proper
update state, the server board provides a BMC Force Update jumper (J1B5) which will force the
BMC into the proper update state. The following procedure should be followed in the event the
standard BMC firmware update process fails.
Table 18. Force IBMC Update Jumper
Jumper Position
Mode of
Operation
Note
1-2
Normal
IBMC GPIO[1] is pulled HIGH. Default position.
2-3
Update
IBMC GPIO[1] is pulled LOW.
1. Power down and remove the AC power cord.
2. Open the server chassis. See your server chassis documentation for instructions.
3. Move jumper from the default operating position, covering pins1 and 2, to the enabled
position, covering pins 2 and 3.
4. Close the server chassis.
5. Reconnect the AC cord and power up the server.