Fiber Optic Cabling
Remove and save the fiber optic connector cover. Insert a fiber optic cable into the ports on the network
adapter bracket as shown.
Most connectors and ports are keyed for proper orientation. If the cable you are using is not keyed, check to
be sure the connector is oriented properly (transmit port connected to receive port on the link partner, and vice
versa).
The adapter must be connected to a compatible link partner that is operating at the same laser wavelength as
the adapter.
CAUTION:
The fiber optic ports contain a Class 1 laser device. When the ports are disconnected,
always cover them with the provided plug. If an abnormal fault occurs, skin or eye damage may res-
ult if in close proximity to the exposed ports.
Connecting Fiber Optic SC Cables
The connection requirements are as follows:
l
Laser wavelength: 850 nanometer (not visible).
l
SX Cable type:
l
Multi-mode fiber with 50 micron core diameter; maximum length is 550 meters.
l
Multi-mode fiber with 62.5 micron core diameter; maximum length is 275 meters.
l
Connector type: SC.