General Installation Process

7

Install DIMM Memory Modules

DDR3 DIMM Memory Identification:

DIMM

notch and

socket

bump must

align as

shown.

Other

Memory

DDR3

This server board supports up to 8 DDR3 800/1066/1333/1600 ECC 

UDIMM/RDIMM.

CAUTION:  

Observe normal ESD (ElectroStatic Discharge) procedures 

to avoid possible damage to system components.

CPU 2 Socket

CPU 1 Socket

D1

DIMM

E1 F1 F2

C2

DIMM

C1 B1 A1

Memory Configurations and Population Order:

Memory Type:

  

Minimum of one 1GB, DDR3 800/1066/1333/1600 MHz ECC UDIMM/RDIMM.

NOTE: For additional memory configurations, see the Techinical Product Specification for Intel

®

 Server Board 

S2400SC at:

http://www.intel.com/support/motherboards/server

Memory sizing and configuration is supported only for qualified DIMMs approved by Intel

®

. For a list of 

supported memory, see the tested memory list at:

http://serverconfigurator.intel.com/default.aspx

Install DIMM Memory Modules

 ... Continued

To Install DIMMs:

Open both DIMM socket levers.

C

A

D
E

Note location of alignment notch.

B

CAUTION: Avoid touching contacts

when handling or installing DIMMs.

A

C

D

B

E

IMPORTANT!  Visually check that each latch is fully closed and correctly engaged with each DIMM edge slot.

Push down firmly on the DIMM until it snaps into place and both levers close.

Insert DIMM making sure the connector edge of the DIMM aligns correctly with the slot.

8

Install Tool-less CD-ROM or DVD-ROM Drive

C

Attach slides to the DVD or CD-ROM drive 

by pressing the slides firmly into the side 

dimples on the DVD or CD-ROM drive.

B

Get the slides from the 

chassis side.

D

Insert the drive/slide assembly 

into the device bay until the 

slides lock into place.

A

Press the release latch and use 

the finger holes to Pull out the 

EMI shield.

Finger Holes

A

D

B

C

Содержание P4304SC2SFEN

Страница 1: ...ts If you are not familiar with ESD Electrostatic Discharge procedures used during system integration see the complete ESD procedures described in your Service Guide This guide and other supporting do...

Страница 2: ...This page is intentionally left blank...

Страница 3: ...ve 6 Install PCI e Card Assembly 7 Install Intel Remote Management Module 4 NIC optional 9 Install RMM4 EMI Cover optional 9 Install Alternate Serial Port optional 9 Install Intel RAID Smart Battery o...

Страница 4: ...ation Configuration Feature 4 x 3 5 Fixed 4 x 3 5 Hot Swap 8 x 3 5 Hot Swap Hard Drive System Fan One Fixed 550W Two Hot Swap 750W Two Hot Swap 460W RMM4 Lite RMM4 Power Supply P4304SC2SFEN P4304SC2SH...

Страница 5: ...5 25 Peripheral Bays Server Board P Intel Remote Management Module 4 Lite Q EMI Cover B A F G H I C D E J K L M N P Q O NOTE Airduct is not shown Intel Server System P4304SC2SFEN System Features and C...

Страница 6: ...ap Power Supply Two I O Ports Alternate Serial Port Knockout PCI Add in Board Slot Covers AC Input Power Connector Two RMM4 Knockout Alternate RMM4 Knockout A Kensington Cable Lock Mounting Hole Padlo...

Страница 7: ...d stop Similarly loosen screws 3 and 4 Repeat steps A and B by giving each screw two rotations each time until all screws are loosened Using a 2 Phillips screwdriver start with screw 1 and loosen it b...

Страница 8: ...wn Install the Processor s continued B Open the Load Plate Open the load plate as shown A B A B Push the rear tab with your finger tip to bring the front end of the load plate up slightly C Remove the...

Страница 9: ...For a list of supported memory see the tested memory list at http serverconfigurator intel com default aspx Install DIMM Memory Modules Continued To Install DIMMs Open both DIMM socket levers C A D E...

Страница 10: ...cooling With the lever open insert the hard disk drive assembly into the cage opening and push until the locking lever engaged Push in the lever to lock it into place then close the door E F TOP BREA...

Страница 11: ...s secured by the chassis Make sure the PCI e card is secured into the slot under the PCI e Card Retainer NOTE Screws are recommended to secure double width cards with chassis back panel 10a Install PC...

Страница 12: ...er Board B Server Board C D Install Full length PCI Card 4 5 For chassis with hotswap drive cage remove the drive cage and the EMI cover insert the fan assembly see letter 3a and then install the driv...

Страница 13: ...A A Attach the metal fastening bracket to Intel Dedicated Server Management NIC module and secure the bracket with two screws B Remove the alternate RMM4 knock out by pressing the knock out from insi...

Страница 14: ...in the direction shown and pull out of the system by the handle NOTE Applies only to the chassis with hot swap power supply configuration 16 Rack Mount Con guration optional If you intend to configur...

Страница 15: ...ers and Operating System Install A Con rm BIOS Version Look on the Server System Management screen in the BIOS Setup Utility to determine the installed BIOS version Compare this to the versions at htt...

Страница 16: ...e D Connect the I2 C cable to I2 C connector on backplane A Connect Mini SAS data cables B Connect two power cables C NOTE Refer to the documents which come with your server board and or RAID controll...

Страница 17: ...ctor On Server Board H PMBus Cable I HSBP_I2 C Cable J PCI Zone System FAN K CPU Zone System FAN Description A CPU1 CPU2 Power Cable B Server Board Main Power Cable C Backplane Power Cable D ODD Power...

Страница 18: ...G63272 001...

Отзывы: