70
Technical Product Specification
Specifications
A.4
MTBF Prediction
lists component, temperature, MTBF, and redundancy information. See table notes at the
bottom of this page.
A.5
Connectors
As shown in
, the ZT 5085's midplane includes several connectors to interface with
application-specific devices. A brief description of each connector is given in
Connector CMM Pin Assignments” on page 89
. A detailed description and pinout for each
connector is given in the following sections.
Table 16. MTBF Prediction on ZT 5085 DC
System
Component
Sub-
Module
Ambient
Temp.
Base
Failure
Rate
Base
MTBF
Qty
Total Sub-System
Failure Rate
Total
Sub-System
MTBF
††Intended
Redundancy
MidPlane
40
3891
257,003
1
3891
257,003
1 + 0
MidPlane
w/o Conn
40
1311
762,777
1
1311
762,777
1 + 0
ZT 7102
40
2086
479,386
2
4172
239,693
1 + 1
Filter
Module
40
178
5,617,978
1
178
5,617,978
1 + 0
Power
MidPlane
40
1495
668,896
2
2990
334,448
2 + 0
Fan Tray†
40
6193
161,473
3
18579
53,824
8 + 1 (Fans)
Power
Supply
25
2183
458,085
8
17464
57,261
(2 + 2) x 2
System
Total
44694
22,374
NOTES:Environmental Assumptions:
1. Failure rates are based on a 25 C inlet chassis temperature with a 15 C increase in internal chassis
temperature
2. Applied electrical component stress levels are 50% (Voltage, Current, and/or Power)
3. Power Supply is at a 50% load.
4. Ground, Fixed, Controlled environment with an environmental adjustment factor equal to 1.0
NOTES:General Assumptions / Notes:
1. Component failure rates are constant
2. Midplane provided with and without to cPCI* Board interconnects
3. Non-electrical components (screws, mechanical latches, labels, covers, chassis) not included within
calculations
4. Printed Circuit Board and wiring cables considered to have a 0 FIT rate
5. Power Supply information was generated using MIL-217 Standard
NOTES:General Notes:
1. Method I, Case I = Based on “Parts Count”. Equipment failure is estimated by totaling device failures rates
and quantities used.
2. Quality Level II = Devices purchased to specifications, qualified devices, vendor lot-to-lot controls for AQLs
and DPMs.
3. Where available, direct component supplier predictions or actual FIT rates have been utilized.
4. †Data used for Delta fans is preliminary
5. ††Indicates the usage redundancy as modeled during development. Actual redundancy of the system is
dependant on customer integration and loading.
Содержание NetStructure ZT 5085
Страница 8: ...8 Technical Product Specification ...
Страница 20: ...20 Technical Product Specification Introduction ...
Страница 46: ...46 Technical Product Specification Field Replaceable Units ...
Страница 60: ...60 Technical Product Specification Cooling Subsystem ...
Страница 92: ...92 Technical Product Specification Specifications ...
Страница 94: ...94 Technical Product Specification Power Supplies Hot Swap Circuitry ...
Страница 96: ...96 Technical Product Specification Data Sheet Reference ...
Страница 100: ...100 Technical Product Specification Warranty Information This page intentionally left blank ...
Страница 102: ...102 Technical Product Specification Customer Support This page intentionally left blank ...