background image

Intel® Compute Module MFS5000SI User 
Guide

A Guide for Technically Qualified Assemblers of Intel

®

 Identified Subassemblies/

Products

Intel Order Number D90834-005

Содержание MFS5000SI - Multi-Flex Server Compute Module

Страница 1: ...Intel Compute Module MFS5000SI User Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies Products Intel Order Number D90834 005...

Страница 2: ...ications and product descriptions at any time without notice Intel server boards contain a number of high density VLSI and power delivery components that need adequate airflow for cooling Intel s own...

Страница 3: ...er Boards and Server Chassis Safety Information unter http support intel com support motherboards server sb cs 010770 htm Consignes de s curit Lisez attention toutes les consignes de s curit et les mi...

Страница 4: ...modems attached to the system before opening it Otherwise personal injury or equipment damage can result Electrostatic discharge ESD and ESD protection ESD can damage disk drives boards and other par...

Страница 5: ...allation Guidelines 7 Removing and Installing an Intel Compute Module MFS5000SI 7 Removing a Compute Module from the Server System 7 Installing a Compute Module into the Server System 8 Opening and Cl...

Страница 6: ...tin America 50 B Warranty 53 Limited Warranty for Intel Chassis Subassembly Products 53 Extent of Limited Warranty 53 Warranty Limitations and Exclusions 54 Limitations of Liability 54 How to Obtain W...

Страница 7: ...urit sur le serveur 72 S curit avertissements et mises en garde 72 Domaines d utilisation pr vus 73 S lection d un emplacement 73 Pratiques de manipulation de l quipement 73 D charges lectrostatiques...

Страница 8: ...viii Intel Compute Module MFS5000SI User Guide...

Страница 9: ...Intel Compute Module MFS5000SI User Guide ix List of Tables Table 1 Compute Module Features 2 Table 2 Diagnostic LED Information 46 Table 3 POST Error Beep Codes 47...

Страница 10: ...x Intel Compute Module MFS5000SI User Guide...

Страница 11: ...sor Air Duct 18 Figure 19 Removing the Heatsink 19 Figure 20 Lifting Processor Socket Handle 19 Figure 21 Opening Load Plate 20 Figure 22 Removing Processor 20 Figure 23 Removing Protective Shipping C...

Страница 12: ...xii Intel Compute Module MFS5000SI User Guide...

Страница 13: ...e main features of the Intel Compute Module MFS5000SI as well as provides illustrations showing the location of important components and connections on the compute module The Intel Compute Module MFS5...

Страница 14: ...FB DIMM Eight DIMM slots Support for DIMM sparing and memory mirroring Chipset Intel 5000P chipset consisting of Intel 5000P Memory Controller Hub MCH Intel 6321ESB I O Controller Hub Peripheral Inte...

Страница 15: ...Midplane Power Connector L USB1 Port C Midplane Signal Connector M CMOS Battery D SAS Connector N Test Connector manufacturing only E FBDIMM Slots O CPU 2 Heatsink F CPU1 Socket P Intel 6321ESB I O C...

Страница 16: ...pdate 1 2 BMC Firmware Force Update Mode Enabled 2 3 BMC Firmware Force Update Mode Disabled Default J4A1 Password Clear 1 2 These pins should have a jumper in place for normal system operation Defaul...

Страница 17: ...minimum of two fully buffered DDR2 667 MHz DIMM s FB DIMM should be installed Additional DIMMs must be installed in pairs up to eight total J3A3 BIOS Bank Select 1 2 If these pins are jumpered the BIO...

Страница 18: ...ort 1 compute module plus all other modules in the system Two power supplies will support 2 to 3 compute modules in any slot plus all other modules in the system Three power supplies will support 4 to...

Страница 19: ...he compute module from the chassis before doing so you must first shut down the operating system and turn off the compute module You do not have to shut down the chassis 3 Blue on a component indicate...

Страница 20: ...ors memory hard drives and expansion cards in the compute module Note The top cover is a required component of the compute module do not attempt to insert a compute module into a server system without...

Страница 21: ...the following figure and slide the top cover back away from the compute module bezel see letter B Lift the top cover up and off the compute module Caution Always replace the top cover before installin...

Страница 22: ...the top cover on the compute module so that it engages the cover guide notches Note Before closing the top cover check that all components are installed and seated correctly and that no loose tools o...

Страница 23: ...Installing a Processor 1 Observe the safety and ESD information at the beginning of this manual and in the appendices 2 If the compute modulecompute module is installed in a server system see Removing...

Страница 24: ...ket handle Figure 9 Lifting Processor Socket Handle 6 Push the rear tab of the load plate with your finger tip see letter A in the following figure to bring the front end of the load plate up slightly...

Страница 25: ...o that the processor cut outs match the socket notches see letter A in the following figure Install the processor see letter B Caution The underside of the processor has components that may damage the...

Страница 26: ...d Figure 13 Removing Socket Protective Cover 10 Lower the processor load plate see letter A in the following figure With your finger push down on the load plate see letter B Lower the socket lever unt...

Страница 27: ...Press firmly on the captive screws and tighten them alternating between screws in a diagonal manner see tightening order in the following figure Do not over tighten the screws by using excessive forc...

Страница 28: ...essors Caution This step only applies if your system has TWO processors For a one processor configuration the second processor air baffle must remain in place to ensure proper cooling Remove the secon...

Страница 29: ...Reinstalling Processor Air Duct 16 Reinstall the top cover For instructions see Replacing and Closing the Top Cover on page 10 17 Reinstall the server compute blade in the server system For instructio...

Страница 30: ...in the appendices 2 If the compute module is installed in a server system see Removing a Compute Module from the Server System on page 7 for removal instructions 3 Remove the top cover For instruction...

Страница 31: ...loosening the captive screws on the heatsink and then gently lifting the heatsink off the processor Figure 19 Removing the Heatsink 6 Push the lever handle down and away from the socket to release it...

Страница 32: ...ip see letter A in the following figure to bring the front end of the load plate up slightly Open the load plate see letter B Figure 21 Opening Load Plate 8 Remove processor Note Do not touch the sock...

Страница 33: ...essor see letter B Caution The underside of the processor has components that may damage the socket pins if installed improperly Processor must align correctly with socket opening before installation...

Страница 34: ...ial side down with the captive screws in line with the holes on the heatsink retention module Press down firmly on the heatsink 14 Press firmly on the captive screws and tighten them alternating betwe...

Страница 35: ...Reinstalling Processor Air Duct 16 Reinstall the top cover For instructions see Replacing and Closing the Top Cover on page 10 17 Reinstall the server compute blade in the server system For instructio...

Страница 36: ...se only DDR2 667 stacked FB DIMM modules In determining your memory requirements the need for memory sparing or memory mirroring must be considered Memory Sparing and Mirroring The chipset includes ha...

Страница 37: ...ve the safety and ESD information at the beginning of this manual and in the appendices 2 If the compute module is installed in a server system see Removing a Compute Module from the Server System on...

Страница 38: ...ute Module MFS5000SI User Guide 4 Remove the processor air duct Figure 29 Removing Processor Air Duct 5 Locate the DIMM sockets 6 Holding the DIMM by the edges remove it from it s packaging 1 I O 2 ID...

Страница 39: ...the DIMM with the keys in the DIMM socket see letter B Insert the bottom edge of the DIMM into the socket and press down on the top edge of the DIMM see letter C until the DIMM is fully seated and th...

Страница 40: ...Reinstalling Processor Air Duct 9 Reinstall the top cover For instructions see Replacing and Closing the Top Cover on page 10 10 Reinstall the server compute blade in the server system For instruction...

Страница 41: ...and in the appendices 2 If the compute module is installed in a server system see Removing a Compute Module from the Server System on page 7 for removal instructions 3 Remove the top cover For instruc...

Страница 42: ...taining clips at each end of the socket see letter A in the following figure This will slightly lift the DIMM from its socket Holding the DIMM by the edges remove it from the socket see letter B Impor...

Страница 43: ...Reinstalling Processor Air Duct 7 Reinstall the top cover For instructions see Replacing and Closing the Top Cover on page 10 8 Reinstall the server compute blade in the server system For instructions...

Страница 44: ...le from the Server System on page 7 for removal instructions 3 Remove the top cover For instructions see Opening and Removing the Top Cover on page 8 4 Holding the mezzanine card by its edges remove i...

Страница 45: ...Compute Module MFS5000SI User Guide 33 7 With a 1 4 inch nut driver install the four standoffs that shipped with the mezzanine card Figure 36 Installing Standoffs for Mezzanine Card AF002457 1 I O 2 I...

Страница 46: ...ur screw holes with the standoffs taking care to position the connector housing on the mezzanine card with the connector on the server board Carefully press the mezzanine card into place until it is f...

Страница 47: ...blade in the server system For instructions see Installing a Compute Module into the Server System on page 8 Removing a Mezzanine Card 1 Observe the safety and ESD information at the beginning of thi...

Страница 48: ...5000SI User Guide 4 Locate the mezzanine card With a Phillips screwdriver remove the four screws securing the mezzanine card to the standoffs Figure 39 Removing Screws from Mezzanine Card 1 I O 2 ID 1...

Страница 49: ...ompute Module MFS5000SI User Guide 37 5 Holding the mezzanine card by its edges gently lift it from the socket and store it in an anti static package Figure 40 Removing Mezzanine Card 1 I O 2 ID 1 2 A...

Страница 50: ...driver secure the four screws previously removed into the holes vacated by the standoffs 8 Reinstall the top cover For instructions see Replacing and Closing the Top Cover on page 10 9 Reinstall the s...

Страница 51: ...og type Lev r det brugte batteri tilbage til leverand ren Advarsel Lithiumbatteri Eksplosjonsfare Ved utskifting benyttes kun batteri som anbefalt av apparatfabrikanten Brukt batteri returneres appara...

Страница 52: ...ttery from its socket 7 Dispose of the battery according to local ordinance 8 Remove the new lithium battery from its package and being careful to observe the correct polarity insert it in the battery...

Страница 53: ...the power supplies Is the compute module fully seated in the chassis Are the processors fully seated in their sockets on the server board Are the installed memory modules fully seated in their sockets...

Страница 54: ...light but will not boot the operating system from the hard drive attempt to boot the from a bootable disk in a USB floppy drive or a USB CD ROM drive 6 If the power LED does not light see Power LED Do...

Страница 55: ...e 46 Verify that the installed processor s are validated for use in the compute module If only a single processor is installed verify that it is installed in the first processor socket Remove and re s...

Страница 56: ...configured for multiple VLANS verify that the network cable is securely attached to the correct switch port Try a different network cable Make sure you are using the correct and most current drivers M...

Страница 57: ...install and reinstall the software Make sure all necessary files are installed If you suspect that a transient voltage spike power outage or brown out might have occurred reload the software and try r...

Страница 58: ...f patterned beep codes to indicate the error conditions LED Name Function Color Indicator Power LED Identifies power state of system Green Off Power is off On Power on Slow Blink Power is in standby o...

Страница 59: ...or occurs or when the BIOS fails to boot to the operating system Please note that not all error conditions are supported by BIOS beep codes Table 3 POST Error Beep Codes Beeps Error Message Descriptio...

Страница 60: ...48 Intel Compute Module MFS5000SI User Guide...

Страница 61: ...nge rate plus applicable taxes Intel reserves the right to change the pricing for telephone support at any time without notice For an updated support contact list see http www intel com support 9089 h...

Страница 62: ...36 9796 via Philippines New Zealand 0800 444 365 Pakistan 632 63684 15 IDD via Philippines Philippines 1 800 1 651 0117 Singapore 65 6213 1311 Taiwan 2 2545 1640 Thailand 1 800 631 0003 Vietnam 632 63...

Страница 63: ...1 Pacifictel Contact AT T USA at 1 800 225 528 Once connected dial 800 843 4481 Guatemala Contact AT T USA at 99 99 190 Once connected dial 800 843 4481 Mexico Contact AT T USA at 001 800 462 628 4240...

Страница 64: ...52 Intel Compute Module MFS5000SI User Guide...

Страница 65: ...defective transportation charges for the return of Product to buyer within the USA will be paid by Intel For all other locations the warranty excludes all costs of shipping customs clearance and other...

Страница 66: ...recovering reprogramming or reproducing any program or data stored in or used with a system containing this product Some jurisdictions do not allow the exclusion or limitation of incidental or consequ...

Страница 67: ...emainder of the original warranty period Telephone Support If you cannot find the information you need on Intel s World Wide Web site http www intel com call your local distributor or an Intel Custome...

Страница 68: ...56 Intel Compute Module MFS5000SI User Guide...

Страница 69: ...ional planning If NEBS compliance is required for system level products additional certification planning and design will be required Product Safety Requirements Electro Magnetic Compatibility EMC Har...

Страница 70: ...uppliers and Outsourced Manufacturers http supplier intel com ehs environmental htm 1 1 Y Product Ecology Europe European Directive 2002 95 EC Restriction of Hazardous Substances RoHS Threshold limits...

Страница 71: ...ng shall all be marked on board 1 1 Y Component Certifications Connectors Require being UL Recognized Rated minimum V 0 and temperature wise suitably rated for its application 1 1 Y Component Certific...

Страница 72: ...60 Intel Compute Module MFS5000SI User Guide...

Страница 73: ...this guide Use of other products components will void the UL Listing and other regulatory approvals of the product and may result in noncompliance with product regulations in the region s in which the...

Страница 74: ...tible to electrical storms we recommend you plug your system into a surge suppressor and disconnect telecommunication lines to your modem during an electrical storm Provided with a properly grounded w...

Страница 75: ...not provided with your product purchase one that is approved for use in your country Caution To avoid electrical shock or fire check the power cord s that will be used with the product as follows Do...

Страница 76: ...ithout the fan guard in place Rack Mount Warnings The equipment rack must be anchored to an unmovable support to prevent it from tipping when a server or piece of equipment is extended from it The equ...

Страница 77: ...refully route cables as directed to minimize airflow blockage and cooling problems For proper cooling and airflow operate the system only with the chassis covers installed Operating the system without...

Страница 78: ...kte oder Komponenten f hrt zum Erl schen der UL Zulassung und anderer Genehmigungen f r das Produkt Dadurch kann das Produkt gegen Produktbestimmungen versto en die im Verkaufsland gelten Sicherheitsh...

Страница 79: ...Ersch tterungsquellen Abgeschirmt von starken elektromagnetischen Feldern die durch elektrische Ger te erzeugt werden In gewittergef hrdeten Gebieten sollten Sie das System an einen berspannungsschutz...

Страница 80: ...k nnen ffnen Sie das Netzteil nicht Im Netzteil bestehen gef hrliche Spannungen Str me und Energiequellen Schicken Sie das Ger t f r Wartungsarbeiten an den Hersteller zur ck Wenn Sie ein hot plug f h...

Страница 81: ...selementen F hren Sie keine Arbeiten im Netzteil aus Das Netzteil enth lt keine f r den Benutzer wartungsbed rftigen Teile Schicken Sie das Ger t f r Wartungsarbeiten an den Hersteller zur ck Schalten...

Страница 82: ...ingebauten Ger te ordnungsgem geerdet sein Elektrostatische Entladungen ESD Vorsicht Elektrostatische Entladungen k nnen zur Besch digung von Festplatten Platinen und anderen Komponenten f hren Daher...

Страница 83: ...nur mit angebrachten Geh useabdeckungen betrieben werden Die Inbetriebnahme des Systems ohne Abdeckung kann zur Besch digung von Systemkomponenten f hren So bringen Sie die Abdeckung wieder an Vergew...

Страница 84: ...r glementaires du produit et le produit peut ne pas tre conforme aux autres lois et r glementations locales applicables au produit S curit avertissements et mises en garde Pour viter de vous blesser...

Страница 85: ...e chaleur telles que la lumi re directe du soleil et les radiateurs l cart des sources de vibration ou des chocs physiques Isol des champs lectromagn tiques importants produits par des appareils lectr...

Страница 86: ...ue vous remplacez un bloc d alimentation chaud d branchez le cordon du bloc d alimentation en cours de remplacement avant de le retirer du serveur Pour viter tout risque d lectrocution mettez le syst...

Страница 87: ...imentation Il ne contient aucune pi ce r parable Renvoyez le au fabricant en cas de probl me Mettez le serveur hors tension et d branchez tous les cordons d alimentation avant d ajouter ou de remplace...

Страница 88: ...ivent tre correctement reli s la terre D charges lectrostatiques ESD Attention Les d charges lectrostatiques ESD peuvent endommager les lecteurs de disque dur les cartes et d autres pi ces Il est fort...

Страница 89: ...refroidissement Afin de permettre une ventilation et un refroidissement corrects ne mettez le syst me en marche que lorsque les panneaux du ch ssis sont en place L utilisation du syst me sans les pann...

Страница 90: ...lar la homologaci n UL y otras certificaciones oficiales del producto pudiendo dejar de ser compatible con las normativas locales de los pa ses en los que se comercializa Advertencias y precauciones s...

Страница 91: ...ada y alejada de fuentes de calor incluida la luz solar directa y los radiadores Alejada de fuentes de vibraci n o de golpes f sicos Aislada de campos electromagn ticos producidos por dispositivos el...

Страница 92: ...tensi n corriente y energ a peligrosos Devu lvala al fabricante para repararla Al reemplazar una fuente de alimentaci n de conexi n en funcionamiento desenchufe el cable de alimentaci n de la fuente d...

Страница 93: ...n No hay elementos en la fuente de alimentaci n que usted pueda reparar y utilizar Devu lvala al fabricante para repararla Apague el servidor y desconecte todos los cables de alimentaci n antes de agr...

Страница 94: ...onexi n a tierra apropiada para el rack y para cada pieza del equipo instalada en el mismo Descarga electrost tica ESD Precauci n Las descargas electrost ticas pueden da ar las unidades de disco las t...

Страница 95: ...e refrigeraci n Para conseguir una refrigeraci n y corriente de aire adecuadas compruebe que cuando sistema est funcionando las cubiertas de la carcasa est n instaladas Si utiliza el sistema sin las c...

Страница 96: ...84 Intel Compute Module MFS5000SI User Guide I nt el I nt el I nt el Web UL...

Страница 97: ...Intel Compute Module MFS5000SI User Guide 85 ITE ITE 5V...

Страница 98: ...86 Intel Compute Module MFS5000SI User Guide...

Страница 99: ...Intel Compute Module MFS5000SI User Guide 87 ESD ESD ESD ESD ESD...

Страница 100: ...88 Intel Compute Module MFS5000SI User Guide...

Страница 101: ...equipment and shall be easily accessible SAFETY STEPS Whenever you remove the chassis covers to access the inside of the system follow these steps 1 Turn off all peripheral devices connected to the sy...

Страница 102: ...s Contact should be made with care Consider wearing protective gloves Danger of explosion if the battery is incorrectly replaced Replace only with the same or equivalent type recommended by the equipm...

Страница 103: ...echselstrom Netzkabel aus der Steckdose bzw dem Netzger t um den Stromanschlu des Systems zu unterbrechen SICHERHEISMASSNAHMEN Immer wenn Sie die Geh useabdeckung abnehmen um an das Systeminnere zu ge...

Страница 104: ...Abdeckung wieder anzubringen 1 Vergewissern Sie sich da Sie keine Werkzeuge oder Teile im Innern des Systems zur ckgelassen haben 2 berpr fen Sie alle Kabel Zusatzkarten und andere Komponenten auf or...

Страница 105: ...sein keine starken von elektrischen Ger ten erzeugten elektromagnetischen Felder aufweisen in Regionen in denen elektrische St rme auftreten mit einem berspannungsschutzger t verbunden sein w hrend ei...

Страница 106: ...l int rieur du syst me suivez les consignes suivantes 1 Mettez hors tension tous les p riph riques connect s au syst me 2 Mettez le syst me hors tension en mettant l interrupteur g n ral en position O...

Страница 107: ...broches aigu s des cartes et aux bords tranchants du capot Nous vous recommandons l usage de gants de protection Danger d explosion si la batterie n est pas remont e correctement Remplacer uniquement...

Страница 108: ...tapa del chasis para acceder al interior del sistema siga las siguientes instrucciones 1 Apague todos los dispositivos perif ricos conectados al sistema 2 Apague el sistema presionando el interruptor...

Страница 109: ...r en cuenta que en el chasis o en el tablero puede haber piezas cortantes o punzantes Por ello se recomienda precauci n y el uso de guantes protectores Existe peligro de explosi n si la pila no se cam...

Страница 110: ...all interno del sistema seguire i seguenti passi 1 Spegnere tutti i dispositivi periferici collegati al sistema 2 Spegnere il sistema usando il pulsante spento acceso dell interruttore del sistema 3...

Страница 111: ...Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio consigliabile l uso di guanti di protezione Esiste il pericolo di un esplosione se la pila non viene sos...

Страница 112: ...100 Intel Compute Module MFS5000SI User Guide...

Отзывы: