Intel® Server System M20NTP1UR - System Integration and Service Guide
58
6.4
System Fan Replacement
Required Tools and Supplies:
•
Intel Spare Fan Kit – iPC
MYP1UFAN
•
Anti-static wrist strap and conductive workbench pad (recommended)
System fans are not hot swappable. The system must be powered off before a faulty system fan can be
replaced.
Warning
: System fans operate at extremely high speeds. Do not attempt to replace a system fan until it has
stopped completely. Attempting to remove a fan that is not completely stopped may result in injury.
1.
Power off the system and remove the system top cover (see
Section 6.1.1
2.
3.
Identify, locate, and remove the faulty system fan (See
Figure 62. System fan assembly removal
•
Disconnect the cable of the selected fan from the server board (see Letter “A”).
•
Lift the system fan up and away from the chassis (see Letter “B”).
4.
Locate and carefully unpack the replacement fan.