background image

ISP2150 2U Rack Server Platform
Quick Start Guide

A Guide for Technically Qualified Assemblers of Intel

®

 Identified

Subassemblies/ Products

Before You Begin

FCC Declaration of Conformity.................................................................................................. 4
Cautions and Warnings ............................................................................................................... 6
Product Regulation Compliance..................................................................................................7
Safety Compliance...................................................................................................................... 7
Electromagnetic Compatibility (EMC) ....................................................................................... 7

ISP2150

Opening and Closing the Front Bezel ......................................................................................... 8
Locking and Unlocking the Front Bezel ..................................................................................... 9
Attaching and Removing the Front Bezel ................................................................................... 9

Installation

Open the Cover ........................................................................................................................... 9
Installing a Microprocessor....................................................................................................... 10
Installing Memory..................................................................................................................... 11
Installing a Hard Drive.............................................................................................................. 13
Installing Add-in Cards............................................................................................................. 14
Installing a Slim-Line CD-ROM Drive..................................................................................... 16
Removing a Diskette Drive....................................................................................................... 17
Re-Installing a Diskette Drive................................................................................................... 17
Close the Cover......................................................................................................................... 17
Installing the Front Bracket and Racking Your System ............................................................ 18
Installing the Front Bracket in a Cabinet................................................................................... 18
Installing the Front Bracket in a Center-Mount, Relay Rack .................................................... 20
Installing the Rail Kit and Racking Your System (Optional Accessory)................................... 21

Technical Reference

Front Panel Controls and Indicators.......................................................................................... 25
Back Panel Connectors .......................................................................................................... ... 26
Jumpers........................................................................................................................ ............. 27
Server Board Components ........................................................................................................ 29

Getting Help

....................................................................................................................................... 30

Order Number: 

 

A13687-001

Содержание ISP2150 - Server Platform - 0 MB RAM

Страница 1: ...Open the Cover 9 Installing a Microprocessor 10 Installing Memory 11 Installing a Hard Drive 13 Installing Add in Cards 14 Installing a Slim Line CD ROM Drive 16 Removing a Diskette Drive 17 Re Insta...

Страница 2: ...rence that may cause undesired operation For questions related to the EMC performance of this product contact Intel Corporation 5200 N E Elam Young Parkway Hillsboro OR 97124 1 800 628 8686 This equip...

Страница 3: ...adian Department of Communications BSMI Taiwan The following EMC Warning along with the BSMI ID number 3882B139 is located on the outside rear area of the product VCCI Japan English translation of the...

Страница 4: ...experience installing and configuring servers Read and adhere to all warnings cautions and notices in this guide and the documentation supplied with the chassis power supply and accessory modules If...

Страница 5: ...urther evaluation Safety Compliance USA UL 1950 CSA 950 95 Canada UL certified to CSA 950 95 for Canada product bears the single UL mark for U S and Canada Europe German GS Mark ERG to EN60950 Interna...

Страница 6: ...Opening and Closing the Front Bezel With the bezel open you have access to all of your system s front panel functions and indicators With the bezel closed you can protect critical functions and still...

Страница 7: ...at the top of the bezel push in the arms on either side of the bezel far enough so that the tabs on the ends of the arms can be inserted into the holes in the chassis 2 Insert the tabs into the holes...

Страница 8: ...eat sink faces the I O connectors Slide the processor into the retention module Push down firmly with even pressure on both sides of the top until the processor is seated 4 To lock in the processor pu...

Страница 9: ...Memory OM09318 The server only supports 100 MHz PC 100 compliant SDRAM Install from 32 MB to 2 GB of unbuffered memory using up to four single or double banked DIMMs Or Install from 32 MB to 2 GB of r...

Страница 10: ...ruption Only install DIMMs with gold plated edge connectors in gold plated sockets To install your memory 1 Open your server 2 Holding the DIMM only by its edges remove it from its anti static package...

Страница 11: ...ve the hard drive from its wrapper and place it on an anti static surface OM09323 C A E B D 3 Remove and save the four screws D from the drive carrier drive slide track 4 Align the drive holes to the...

Страница 12: ...You must use the PCI slots on the riser card Do not use any expansion slots on the server board 1 Remove the expansion slot cover for the slot you wish to use Remove the thumbscrew B holding the cover...

Страница 13: ...g slot in the expansion slot frame Install the board component side DOWN NOTE If you are installing a full length PCI card slide the card guide in front of the fans before installing the card 5 Align...

Страница 14: ...CD tray using the mounting screws A supplied with the system 4 Remove the screws that hold the filler panel to the front of the chassis and slide out the panel 5 Slide the slim line CD tray into the C...

Страница 15: ...e wrapper if you are not reinstalling it Re Installing a Diskette Drive 1 Remove the 3 5 inch diskette drive from its protective wrapper and place it component side up on an anti static surface 2 Inst...

Страница 16: ...er to the specifications provided by the manufacturer to insure proper mounting configurations and maximum specified loads for the rack or cabinet are not exceeded Installing the Front Bracket in a Ca...

Страница 17: ...net using the supplied mounting bolts C supplied by the cabinet manufacturer 4 Slide the system into the back support bracket After attaching the rear brackets slide the system into the rack using the...

Страница 18: ...ting bolts B to attach them to the system Mount the brackets mid way down the sides of the system as shown in the figure NOTE You can also mount the bracket so that the flange is flush with the front...

Страница 19: ...ewdriver and assorted lock washers and nuts 2 Remove the inside piece C from both sides of the rail system To remove an inside piece of the rail system slide the part as far out as you can This action...

Страница 20: ...all four rail brackets to the cabinet rack Be sure that the sharper angled side of each bracket is facing up C Use eight mounting screws D provided by the manufacturer of the cabinet rack In the illu...

Страница 21: ...hat you can secure the bolt Do not tighten the nut and bolt until you have aligned the rear portion of the rail system see the next step 8 To attach the rear part of the rail system to the rear rail b...

Страница 22: ...the chassis system into the outer pieces B you attached in previous steps Gently move the system evenly towards the rear of the cabinet Be sure to depress the brass colored finger tabs located in the...

Страница 23: ...ols and Indicators OM09320 H A E B C D F G I L K J M A Power button B Sleep button C Reset button D Power LED E NIC activity LED F Fail LED G Disk activity fail LEDs H Hard drive bay I Hard drive ejec...

Страница 24: ...Power supply fault indicator F Video connector G USB connectors H RJ45 network connector I Serial port connector Com 1 J Serial port connector Com 2 K Keyboard connector NIC LED Color If it s on If i...

Страница 25: ...current you must move the WOL Enable jumper to this position 2 3 Enabled Enables Wake On LAN J4J2 BMC WR EN 1 2 Protect BMC boot block is write protected 2 3 Erase Program BMC boot block is erasable a...

Страница 26: ...the BIOS code has been corrupted J2J1 BIOS WR EN 13 14 Protect BIOS boot block is write protected 14 15 Erase Program BIOS boot block is erasable and programmable CAUTION Moving either of the boot bl...

Страница 27: ...lated Server Management ISOL IMB connector O Jumper block P Jumper block Q Fan connector 1 R Ultra wide SCSI connector S Server Monitor Module SMM connector T External Wake on LAN connector U Ultra2 L...

Страница 28: ...our ce produit est disponible l adresse suivante Unterst tzung zu diesem Produkt erhalten Sie unter der folgenden Webadresse possibile ottenere supporto per questo prodotto al seguente indirizzo Podr...