The latest version of an operating system signifies the latest supported version 
at the time of the actual test run.  Each new release of this document may have 
a newly supported release of a given operating system.  Previous releases of a 
supported operating system may not be tested beyond the basic installation 
test process. 

 

1.1.1.1 

Support Commitment for Basic Installation Testing 

Intel commits to provide the following level of customer support for operating systems that 
receive only basic installation testing: 

 

Intel will provide and test operating system drivers for each of the server board’s 
integrated controllers, provided that the controller vendor has a driver available upon 
request.  Vendors will not be required by Intel to develop drivers for operating systems 
that they do not already support.  This may limit the functionality of certain server board 
integrated controllers.   

 

Intel will support customer issues that involve installation and/or functionality of 
operating system with the server board’s integrated controllers only if a driver has been 
made available. 

 

Intel will NOT provide support for issues related to use of any add-in adapters or 
peripherals installed in the server system when an operating system that received basic 
installation testing only is in use. 

 

Support is defined as assistance in root causing issues, and determining a customer 
acceptable resolution to the issue associated with the operating system.  The resolution 
may include, but is not limited to, on-board controller driver changes, engaging the 
vendor for resolution, BIOS changes, firmware changes, or determining a customer 
acceptable workaround for the issue. 

 

1.1.2 

Adapter / Peripheral Compatibility and Stress Testing 

Adapter / Peripheral Compatibility and Stress testing is performed only on the most current 
release of a supported operating system at the time of a given validation run.  The Adapter / 
Peripheral Compatibility and Stress testing process consists of three areas:  Base Platform, 
Adapter Compatibility, and Stress. 

Base Platform

: Each base platform will successfully install a given operating system, 

successfully run a disk stress test, and successfully run a network stress test. 

Adapter Compatibility

:  Adapter compatibility validation (CV) testing uses test suites to gain an 

accurate view of how the server performs with a wide variety of adapters under the primary 
supported operating systems.  These tests are designed to show hardware compatibility 
between the add-in cards and the server platform and include functional testing only.  No heavy 
stressing of the systems or the cards is performed for CV testing. 

Stress Testing

: This test sequence uses configurations that include add-in adapters in all 

available PCI slots for a minimum 72-hour test run without injecting errors.  Each configuration 
passes an installation test, a Network/Disk Stress test, and tape backup test.  Any fatal errors 
that occur will require a complete test restart. 

Содержание IP Network server NSI2U

Страница 1: ...Intel Carrier Grade Server TIGI2U Intel IP Network Server NSI2U Tested Hardware and Operating System List Revision 1 3 September 2006 Enterprise Platforms and Services Marketing...

Страница 2: ...ducts Intel assumes no liability whatsoever and Intel disclaims any express or implied warranty relating to sale and or use of Intel products including liability or warranties relating to fitness for...

Страница 3: ...tems Supported but not Tested 6 3 2 Operating System Certifications 6 4 Adapters and Peripherals 8 4 1 PCI SCSI RAID 10 4 2 PCI SATA RAID 10 4 3 PCI SCSI 11 4 4 PCI MROMB 12 4 5 PCI Fibre Channel 12 4...

Страница 4: ......

Страница 5: ...following server building blocks and integrated systems Product Code Product Description TLIA0201 Intel Carrier Grade Server TIGI2U Server Board SE7520JR2 Onboard SCSI DDR2 400 MHz Two PCI Risers 20...

Страница 6: ...ning a customer acceptable resolution to the issue associated with the operating system The resolution may include but is not limited to on board controller driver changes engaging the vendor for reso...

Страница 7: ...tomers do not run across any problems but the actual certification is the responsibility of the individual customer For operating systems adapter cards and peripherals not listed in this document ther...

Страница 8: ...in this family of products This table is updated when a new test run is performed and a new product system software combination was used Intel will only provide support for adapters and peripherals un...

Страница 9: ...Intel s best known methods Operating systems supported by Intel Server Management software or LANDesk Client Manager software may be different than the operating systems supported by the Intel Server...

Страница 10: ...ystem Certifications Listed below are the operating systems that Intel will certify with the Intel Carrier Grade Server TIGI2U and the Intel IP Network Server NSI2U However the customer is responsible...

Страница 11: ...http bugzilla redhat com hwcert show cgi id 1648 44 TIGI2U Server http bugzilla redhat com hwcert show cgi id 1802 63 SuSE Linux Enterprise Server 9 Service Pack 1 SuSE Linux Enterprise Server 9 Servi...

Страница 12: ...is supported but not tested This adapter is supported but not tested This adapter model has not been tested with this server board but Intel will support it based on successful testing of a similar ad...

Страница 13: ...ormed with unused add in adapters and onboard controller expansion ROMs disabled in BIOS Setup Intel recommends that customers disable the option ROM for add in controllers and or the on board control...

Страница 14: ...314G 1 2 2 1 2 1 2 Intel SRCU42E Rumley PCI E x8 BIOS H423 FW 514F 2 2 2 2 Intel SRCU42L SRCU42L PCI 64 66 BIOS 7 05C FW 2 42 02 R07A 2 3 2 3 2 3 2 3 Intel SRCU42X SRCU42X PCI X133 BIOS H424 FW 413Z 1...

Страница 15: ...l SRCS28X SRCS28X PCI X133 BIOS H425 FW 813G 2 2 2 2 LSI Logic MegaRAID SATA 150 6 MegaRAID SATA 150 6 PCI 64 66 BIOS G119 FW 713N 2 3 2 3 2 3 2 3 LSI Logic MegaRAID SATA 150 4 MegaRAID SATA 150 4 PCI...

Страница 16: ...c LSI20160L LSI20160L PCI 32 33 SA SA SA SA LSI Logic LSI22320 R LSI22320 R PCI X133 BIOS 5 10 03 FW 1 3 39 1 2 3 2 3 1 2 3 1 2 3 LSI Logic LSI20320 R LSI20320 R PCI X133 Similar Adapter LSI22320 R SA...

Страница 17: ...BIOS 2 02 00 FW 1 02 02 2 2 2 2 LSI Logic LSI7102XP LC LSI7102XP LC PCI X133 Similar Adapter LSI7202XP LC SA SA SA SA LSI Logic LSI7402XP LC LSI7402XP LC PCI X133 Similar Adapter LSI7202XP LC SA SA S...

Страница 18: ...8490XT SA SA SA SA Intel PWLA8490XTL PRO 1000XTL Gigabit Server Adapter PCI X133 Similar Adapter PWLA8490XT SA SA SA SA Intel PWLA8492MT PRO 1000MT Dual Port Gigabit Server Adapter PCI X133 2 3 2 3 1...

Страница 19: ...33 0121 Internet Navigator PS 2 and USB Keyboard 1 2 2 1 2 1 2 LOGITECH 967233 0403 Internet Navigator PS 2 and USB Similar Adapter 967233 0121 SA SA SA SA 4 9 CDROM Drives IBM 22P6991 24x10x24 IDE Sl...

Страница 20: ...NT 1 1 Sony CRX835 L1 CRX835 L1 ATA33 Teac DV 28E BP3 DV 28E BP3 ATA33 1 2 2 1 2 1 2 Teac DW 224E C98 DW 28E C98 ATA33 3 4 Teac DV W28EA 593 DV W28EA 593 ATA33 3 4 4 11 Tape Drives Certance STD2401LW...

Страница 21: ...0 Intel EM64T Edition Red Hat Enterprise Linux 3 0 Red Hat Enterprise Linux 4 0 Red Hat Enterprise Linux 3 0 Intel EM64T Edition SuSE Linux Enterprise Server 9 SuSE Linux Enterprise Server 9 4 13 KVM...

Страница 22: ...fication number Number in brackets i e 1 This hard drive has been tested but is NOT supported under the operating system identified by the operating system identification number SD Similar Drive The h...

Страница 23: ...300GB 1 3 Hitachi HUS103014EL3 800 Ultrastar 10K300 SCSI U320 10 000 147GB 1 3 Hitachi HUS103073EL3 800 Ultrastar 10K300 SCSI U320 10 000 73GB 1 3 Hitachi HUS103036EL3 800 Ultrastar 10K300 SCSI U320 1...

Страница 24: ...ta 15K 4 SCSI U320 15 000 73GB 1 2 3 4 Seagate ST336754LC Cheeta 15K 4 SCSI U320 15 000 36GB 5 3 7 3 SD Seagate ST3146854LC Cheeta 15K 4 SCSI U320 15 000 146GB SD Serial ATA SATA Hard Drives Hitachi H...

Страница 25: ...Manufacturer Model Number Product Family Interface RPM Drive size GB Tested Operating Systems Notes Western Digital WD360GD WD Raptor SATA 150 10 000 36GB SD Note Blue shading indicates that the adapt...

Страница 26: ...n ROM utility Ctrl M for the following LSI adapters MegaRAID 320 2 MegaRAID 320 1 MegaRAID 320 0 MegaRAID SATA 150 6 MegaRAID SATA 150 4 and older U160 SCSI MegaRAID adapters Guideline BIOS P07 20 or...

Отзывы: