background image

 

Adapters and Peripherals 

Revision 1.3 

  

 

 

11 

Manufacturer 

Model Number 

Model Name 

Interface 

Comments 

Microsoft W

indows 

2003* EE / SBS 2003 

Microsoft W

indows 

2003* EM64T Edition 

Red Hat* Enterprise 

Linux 3.0 (Intel® 

EM64T Edition

Red Hat* Enterprise 

Linux 3.0  

Red Hat* Enterprise 

Linux 4.0 

R

e

d

 H

a

t*

 E

n

terpr

ise 

Linux 3.0 (Intel® 

EM64

T

E

dition)

SuSE* Linux 

Enterprise Server 9, 

SuSE* Linux 

Enterprise Server 9, 

AMCC/3ware 9500S-12ML 

9500S-12ML PCI-X66 

SA 9500S-8 

SA 

SA

SA 

SA 

 

 

 

 

AMCC/3ware 9500S-4LP 

9500S-4LP PCI-X66 

SA 9500S-8 

SA 

SA

SA 

SA 

 

 

 

 

AMCC/3ware 9500S-8ML 

9500S-8ML 

PCI-X66 

SA 9500S-8 

SA 

SA

SA 

SA 

 

 

 

 

ICP Vortex 

GDT8586RZ 

GDT8586RZ 

PCI-64/66 

BIOS:7.05D 

FW:2.44.02-

RC7B 

 

 

 

 

Intel SRCS14L 

SRCS14L 

PCI-64/66 

BIOS:7.05C 

FW:2.42.02-R07A

1,2 2 1,2 1,2 

 

 

 

 

Intel SRCS16 

SRCS16 

PCI-64/66 

BIOS:G401 

FW:713N 

2 2 

1,2 

1,2 

 

 

 

 

Intel 

SRCS28X 

SRCS28X 

PCI-X133 

BIOS:H425 

FW:813G 

 

 

 

 

LSI Logic 

MegaRAID SATA 
150-6 

MegaRAID SATA 150-

PCI-64/66 

BIOS:G119 

FW:713N 

2,3 

2,3

2,3 

2,3 

 

 

 

 

LSI Logic 

MegaRAID SATA 
150-4 

MegaRAID SATA 150-

PCI-64/66 

Similar Adapter 

MegaRAID SATA 

150-6 

SA 

SA

SA 

SA 

 

 

 

 

Promise* 

FastTrak S150 TX4 

FastTrak S150 TX4 

PCI-32/66 

FW 1.00.0.30 

1  [1] 

1     

D-Link DGE-550T 

GigaExpress 

DGE-

550T 

PCI -66 

 1 

 

 

 

 

 

4.3  PCI SCSI  

 

 

 

 

 

 

 

 

 

 

 

 

Adaptec

(1) 

ASC-29160 

ASC-29160 

PCI-64/66 

BIOS:3.10.0 

1,2 

1,2 

1,2 

 

 

 

 

Adaptec 

ASC-29160LP 

ASC-29160LP 

PCI-64/66 

Similar Adapter 

ASC-29160 

SA 

SA

SA 

SA 

 

 

 

 

Adaptec 

ASC-29160N 

ASC-29160N 

PCI-64/66 

Similar Adapter 

ASC-29160 

SA 

SA

SA 

SA 

 

 

 

 

Adaptec 

ASC-39160 

ASC-39160 

PCI-64/66 

BIOS:3.10.0 

1,2,3

2,3

2,3 

2,3 

 

 

 

 

Adaptec ASC-39320-A 

ASC-39320-A PCI-X133 

BIOS:4.25.0 

2,3 2,3

1,2,3

1,2,3

       

Adaptec ASC-39320D-R 

ASC-39320D-R PCI-X133 

Similar 

Adapter 

ASC-39320-A 

SA SA

SA SA  

 

 

 

Adaptec ASC-39320-R 

ASC-39320-R 

PCI-X133 Similar 

Adapter 

ASC-39320-A 

SA SA

SA SA  

 

 

 

Adaptec 

ASC-29320ALP 

ASC-29320ALP 

PCI-X133 

BIOS:4.30.0 

1,2 

1,2 

1,2 

 

 

 

 

Содержание IP Network server NSI2U

Страница 1: ...Intel Carrier Grade Server TIGI2U Intel IP Network Server NSI2U Tested Hardware and Operating System List Revision 1 3 September 2006 Enterprise Platforms and Services Marketing...

Страница 2: ...ducts Intel assumes no liability whatsoever and Intel disclaims any express or implied warranty relating to sale and or use of Intel products including liability or warranties relating to fitness for...

Страница 3: ...tems Supported but not Tested 6 3 2 Operating System Certifications 6 4 Adapters and Peripherals 8 4 1 PCI SCSI RAID 10 4 2 PCI SATA RAID 10 4 3 PCI SCSI 11 4 4 PCI MROMB 12 4 5 PCI Fibre Channel 12 4...

Страница 4: ......

Страница 5: ...following server building blocks and integrated systems Product Code Product Description TLIA0201 Intel Carrier Grade Server TIGI2U Server Board SE7520JR2 Onboard SCSI DDR2 400 MHz Two PCI Risers 20...

Страница 6: ...ning a customer acceptable resolution to the issue associated with the operating system The resolution may include but is not limited to on board controller driver changes engaging the vendor for reso...

Страница 7: ...tomers do not run across any problems but the actual certification is the responsibility of the individual customer For operating systems adapter cards and peripherals not listed in this document ther...

Страница 8: ...in this family of products This table is updated when a new test run is performed and a new product system software combination was used Intel will only provide support for adapters and peripherals un...

Страница 9: ...Intel s best known methods Operating systems supported by Intel Server Management software or LANDesk Client Manager software may be different than the operating systems supported by the Intel Server...

Страница 10: ...ystem Certifications Listed below are the operating systems that Intel will certify with the Intel Carrier Grade Server TIGI2U and the Intel IP Network Server NSI2U However the customer is responsible...

Страница 11: ...http bugzilla redhat com hwcert show cgi id 1648 44 TIGI2U Server http bugzilla redhat com hwcert show cgi id 1802 63 SuSE Linux Enterprise Server 9 Service Pack 1 SuSE Linux Enterprise Server 9 Servi...

Страница 12: ...is supported but not tested This adapter is supported but not tested This adapter model has not been tested with this server board but Intel will support it based on successful testing of a similar ad...

Страница 13: ...ormed with unused add in adapters and onboard controller expansion ROMs disabled in BIOS Setup Intel recommends that customers disable the option ROM for add in controllers and or the on board control...

Страница 14: ...314G 1 2 2 1 2 1 2 Intel SRCU42E Rumley PCI E x8 BIOS H423 FW 514F 2 2 2 2 Intel SRCU42L SRCU42L PCI 64 66 BIOS 7 05C FW 2 42 02 R07A 2 3 2 3 2 3 2 3 Intel SRCU42X SRCU42X PCI X133 BIOS H424 FW 413Z 1...

Страница 15: ...l SRCS28X SRCS28X PCI X133 BIOS H425 FW 813G 2 2 2 2 LSI Logic MegaRAID SATA 150 6 MegaRAID SATA 150 6 PCI 64 66 BIOS G119 FW 713N 2 3 2 3 2 3 2 3 LSI Logic MegaRAID SATA 150 4 MegaRAID SATA 150 4 PCI...

Страница 16: ...c LSI20160L LSI20160L PCI 32 33 SA SA SA SA LSI Logic LSI22320 R LSI22320 R PCI X133 BIOS 5 10 03 FW 1 3 39 1 2 3 2 3 1 2 3 1 2 3 LSI Logic LSI20320 R LSI20320 R PCI X133 Similar Adapter LSI22320 R SA...

Страница 17: ...BIOS 2 02 00 FW 1 02 02 2 2 2 2 LSI Logic LSI7102XP LC LSI7102XP LC PCI X133 Similar Adapter LSI7202XP LC SA SA SA SA LSI Logic LSI7402XP LC LSI7402XP LC PCI X133 Similar Adapter LSI7202XP LC SA SA S...

Страница 18: ...8490XT SA SA SA SA Intel PWLA8490XTL PRO 1000XTL Gigabit Server Adapter PCI X133 Similar Adapter PWLA8490XT SA SA SA SA Intel PWLA8492MT PRO 1000MT Dual Port Gigabit Server Adapter PCI X133 2 3 2 3 1...

Страница 19: ...33 0121 Internet Navigator PS 2 and USB Keyboard 1 2 2 1 2 1 2 LOGITECH 967233 0403 Internet Navigator PS 2 and USB Similar Adapter 967233 0121 SA SA SA SA 4 9 CDROM Drives IBM 22P6991 24x10x24 IDE Sl...

Страница 20: ...NT 1 1 Sony CRX835 L1 CRX835 L1 ATA33 Teac DV 28E BP3 DV 28E BP3 ATA33 1 2 2 1 2 1 2 Teac DW 224E C98 DW 28E C98 ATA33 3 4 Teac DV W28EA 593 DV W28EA 593 ATA33 3 4 4 11 Tape Drives Certance STD2401LW...

Страница 21: ...0 Intel EM64T Edition Red Hat Enterprise Linux 3 0 Red Hat Enterprise Linux 4 0 Red Hat Enterprise Linux 3 0 Intel EM64T Edition SuSE Linux Enterprise Server 9 SuSE Linux Enterprise Server 9 4 13 KVM...

Страница 22: ...fication number Number in brackets i e 1 This hard drive has been tested but is NOT supported under the operating system identified by the operating system identification number SD Similar Drive The h...

Страница 23: ...300GB 1 3 Hitachi HUS103014EL3 800 Ultrastar 10K300 SCSI U320 10 000 147GB 1 3 Hitachi HUS103073EL3 800 Ultrastar 10K300 SCSI U320 10 000 73GB 1 3 Hitachi HUS103036EL3 800 Ultrastar 10K300 SCSI U320 1...

Страница 24: ...ta 15K 4 SCSI U320 15 000 73GB 1 2 3 4 Seagate ST336754LC Cheeta 15K 4 SCSI U320 15 000 36GB 5 3 7 3 SD Seagate ST3146854LC Cheeta 15K 4 SCSI U320 15 000 146GB SD Serial ATA SATA Hard Drives Hitachi H...

Страница 25: ...Manufacturer Model Number Product Family Interface RPM Drive size GB Tested Operating Systems Notes Western Digital WD360GD WD Raptor SATA 150 10 000 36GB SD Note Blue shading indicates that the adapt...

Страница 26: ...n ROM utility Ctrl M for the following LSI adapters MegaRAID 320 2 MegaRAID 320 1 MegaRAID 320 0 MegaRAID SATA 150 6 MegaRAID SATA 150 4 and older U160 SCSI MegaRAID adapters Guideline BIOS P07 20 or...

Отзывы: