4 0
GS-SR195V Rack Mount Server
Thermal Managerment 2
Select between TM1 and TM2.
Enabled
Select Thermal Management 2 function.
Disabled
Disable this function.
(Default value)
Adjacent Cache Line Prefetch
Enabled
Processor will fetch both cache lines when it requires data that is not
currently inits cache. (Defualt value)
Disabled
Processor will only fetch the cache line that contains the data currently
required by the processor.
Set Max Ext CPUID = 3
Set MAX CPUID extended function value to 3.
Enabled
Enable Set Max Ext CPUID = 3 function.
Disabled
Disable this function.
(Default value)
Thermal Managerment 1
If enabled, when the thermal sensor indicates that the die temperature is at the pre-determined
threshold, the processor will reduce the bus to core ratio and operating voltage.
Enabled
Enable Thermal Management 1 function.
(Default value)
Disabled
Disable this function.
NX Protection
This category provides user to enable virus protection avoiding unknow and spite attack.
Enabled
NX Protection function.
(Default value)
Disabled
Disable this function.