SSI
ERP2U Power Supply Design Guide,
V1.0
- 29 -
Asset Tag
{Not used, code is zero length byte}
FRU File ID
{Not required}
PAD Bytes
{Added as necessary to allow for 8 -byte offset to next area}
8.3.3.2 MultiRecord Area
As defined by the IPMI FRU document. The following record types shall be used on this power supply:
•
Power Supply Information (Record Type 0x00)
•
DC Output (Record Type 0x01)
•
No other record types are required for the power supply.
MultiRecord information shall be defined as follows:
Table 27: FRU Device Product Information Area
Field Name (PS Info)
Field Information Definition
Overall Capacity (watts)
480
Peak VA
550
Inrush current (A)
50
Inrush interval (ms)
5
Low end input voltage range 1
90
High end input voltage range 1 140
Low end input voltage range 2
180
High end input voltage range 2 264
A/C dropout tol. (ms)
20
Binary flags
Set for: Hot Swap support, Autoswitch, and PFC
Peak Wattage
Set for: 10 s, 550 W
Combined wattage
Set for 5 V & 3.3V combined wattage of 115 W
Predictive fail tach support
Not supported, 00h value
Field Name (Output)
Field Description:
Five outputs are to be defined from #1 to #5, as follows: +3.3 V, +5
V, +12 V, -12V, and +5 VSB.
Output Information
Set for: Standby on +5 VSB, No Standby on all others.
All other output fields
Format per IPMI specification, using parameters in the EPS12V
specification.