Electrical Specifications
16
Quad-Core Intel® Xeon® Processor 5300 Series Datasheet
2.2
Power and Ground Lands
For clean on-chip processor core power distribution, the processor has 223 V
CC
(power)
and 267 V
SS
(ground) inputs. All V
CC
lands must be connected to the processor power
plane, while all V
SS
lands must be connected to the system ground plane. The
processor V
CC
lands must be supplied with the voltage determined by the processor
V
oltage
ID
entification (VID) signals. See
Table 2-3
for VID definitions.
Twenty two lands are specified as V
TT
, which provide termination for the FSB and
provides power to the I/O buffers. The platform must implement a separate supply for
these lands which meets the V
TT
specifications outlined in
Table 2-12
.
2.3
Decoupling Guidelines
Due to its large number of transistors and high internal clock speeds, the processor is
capable of generating large average current swings between low and full power states.
This may cause voltages on power planes to sag below their minimum values if bulk
decoupling is not adequate. Larger bulk storage (C
BULK
), such as electrolytic capacitors,
supply current during longer lasting changes in current demand by the component,
such as coming out of an idle condition. Similarly, they act as a storage well for current
when entering an idle condition from a running condition. Care must be taken in the
baseboard design to ensure that the voltage provided to the processor remains within
the specifications listed in
Table 2-12
. Failure to do so can result in timing violations or
reduced lifetime of the component. For further information and guidelines, refer to the
appropriate platform design guidelines.
2.3.1
V
CC
Decoupling
Vcc regulator solutions need to provide bulk capacitance with a low Effective Series
Resistance (ESR), and the baseboard designer must assure a low interconnect
resistance from the regulator (EVRD or VRM pins) to the LGA771 socket. Bulk
decoupling must be provided on the baseboard to handle large current swings. The
power delivery solution must insure the voltage and current specifications are met (as
defined in
Table 2-12
). For further information regarding power delivery, decoupling
and layout guidelines, refer to the appropriate platform design guidelines
.
2.3.2
V
TT
Decoupling
Bulk decoupling must be provided on the baseboard. Decoupling solutions must be
sized to meet the expected load. To insure optimal performance, various factors
associated with the power delivery solution must be considered including regulator
type, power plane and trace sizing, and component placement. A conservative
decoupling solution consists of a combination of low ESR bulk capacitors and high
frequency ceramic capacitors. For further information regarding power delivery,
decoupling and layout guidelines, refer to the appropriate platform design guidelines.
Содержание E5345 - Xeon 2.33 GHz 8M L2 Cache 1333MHz FSB LGA771 Active Quad-Core Processor
Страница 1: ...Order Number 315569 Revision 001 Quad Core Intel Xeon Processor 5300 Series Datasheet November 2006...
Страница 8: ...8 Quad Core Intel Xeon Processor 5300 Series Datasheet...
Страница 14: ...Introduction 14 Quad Core Intel Xeon Processor 5300 Series Datasheet...
Страница 38: ...Electrical Specifications 38 Quad Core Intel Xeon Processor 5300 Series Datasheet...
Страница 48: ...Mechanical Specifications 48 Quad Core Intel Xeon Processor 5300 Series Datasheet...
Страница 70: ...Land Listing 70 Quad Core Intel Xeon Processor 5300 Series Datasheet...
Страница 96: ...Features 96 Quad Core Intel Xeon Processor 5300 Series Datasheet...