background image

Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide

13

Figure 5. RMS2AF040 Hardware Block Diagram

Содержание AXXRMS2AF040

Страница 1: ...Intel Integrated RAID Module RMS2AF040 AXXRMS2AF040 and RMS2AF080 AXXRMS2AF080 Hardware User s Guide Intel Order Number E93119 002...

Страница 2: ...SE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE MERCHANTABILITY OR INFRINGEMENT OF ANY PATENT COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT Intel p...

Страница 3: ...ineers who are designing an Intel RAID Module RMS2AF040 or RMS2AF080 for their RAID system Anyone installing an Intel RAID Module RMS2AF040 or RMS2AF080 in their RAID system Organization This document...

Страница 4: ...iv Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide...

Страница 5: ...dware Installation 7 Requirements 7 Installing the RAID Module 7 Configuring the RAID Module 10 Replacing a Controller Resolving a Config Mismatch 10 Intel Integrated RAID Module RMS2AF0x0 Characteris...

Страница 6: ...t 24 RAID Functionality and Features 24 Hierarchy 24 SAS Bus and ID Mapping 26 A Drive Roaming and Drive Migration Install 27 Drive Roaming 27 Drive Migration 28 B Installation Assembly Safety Instruc...

Страница 7: ...ted RAID Module RMS2AF0x0 8 Figure 3 Connecting Cable between the RAID Module and Drives Backplane 9 Figure 4 Card Layout 11 Figure 5 RMS2AF040 Hardware Block Diagram 13 Figure 6 RMS2AF080 Hardware Bl...

Страница 8: ...viii Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide...

Страница 9: ...1 Jumper Description 12 Table 2 SAS SATA Connector Pin out 17 Table 3 Host Board Interface Connector Pin Out 19 Table 4 Technical Specifications 20 Table 5 Array Performance Features 21 Table 6 Fault...

Страница 10: ...x Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide...

Страница 11: ...onnectors lower pin counts and lower power requirements than parallel SCSI Benefits of SAS and SATA SAS is a serial point to point enterprise level device interface that leverages the proven SCSI prot...

Страница 12: ...r Board S5520UR Intel Server Board S5520HC S5520HCT Intel Server Board S5500HCV Intel Workstation Board S5520SC Intel Server Board S3420GP Intel Server System SR1600UR Intel Server System SR2600UR Int...

Страница 13: ...server board See the Tested operating system list for your server board at http www intel com support go motherboards server index htm To make sure the RAID module supports your operating system see...

Страница 14: ...to the drive for a missing drive to be marked as failed Auto resume on reboot of initialization or rebuild must be enabled before virtual disk creation Smart initialization automatically checks consis...

Страница 15: ...r Chip Online Capacity Expansion and RAID Level Migration Rules Migration must occur to the same or larger capacity configuration Migration cannot occur if there is more than one virtual disk in an ar...

Страница 16: ...6 Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide...

Страница 17: ...low these steps 1 Turn off the power to the system all drives enclosures and system components Remove the power cord s 2 Remove the server cover For instructions see your server system documentation 3...

Страница 18: ...regarding connecting the recommended Right angle end or Vertical end of the SAS SATA cable to the SAS connectors of the controller see your server workstation board or chassis documentation Make sure...

Страница 19: ...Route SAS cables carefully Use only straight SAS cables not cross over SAS cables Figure 3 Connecting Cable between the RAID Module and Drives Backplane 7 Install the server system cover and connect t...

Страница 20: ...odule follows the PCI slot scanning order used by the server board 3 Follow the instructions in the Intel RAID Software User s Guide Document Number D29305 0xx to configure the RAID module and to inst...

Страница 21: ...Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide 11 3 Intel Integrated RAID Module RMS2AF0x0 Characteristics Figure 4 Card Layout AF003490 J1 J2 J3 J4 J5 J6 J7 J8 J9 J10 J11...

Страница 22: ...SAS SATA Port 3 J5 SAS SATA Port 4 J6 SAS SATA Port 5 J7 SAS SATA Port 6 J8 SAS SATA Port 7 J5 J8 Ports 4 7 are only available on Intel RAID Module RMS2AF080 J9 Keyed SGPIO Connector 4 pin keyed conne...

Страница 23: ...Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide 13 Figure 5 RMS2AF040 Hardware Block Diagram...

Страница 24: ...provides eight independent PHYs Intel Intergrade RAID Module RMS2AF040 provides four independent PHYs each supporting 6Gb s and 3Gb s SAS data transfers per PHY Supports SSP to enable communication wi...

Страница 25: ...I LSISAS2008 Processor Chip before the server board configures the PCI Express registers The bootstrap ROM sets the Phase Lock Loop PLL dividers bootstrap configuration and so on NVSRAM A 32 KB NVSRAM...

Страница 26: ...SAS SATA Connector Pin out The SAS SATA connector shown in the following figure is the standard 7 pin SATA internal connector used by the Intel Integrated RAID Module RMS2AF040 and RMS2AF080 These pin...

Страница 27: ...Guide 17 Table 2 SAS SATA Connector Pin out Figure 9 SAS SATA Cable Pin Signal Description 1 GND Ground 2 TX0 Transmitter differential pair 3 TX0 Transmitter differential pair 4 GND Ground 5 RXD Rece...

Страница 28: ...ntel Integrated RAID Module RMS2AF040 and RMS2AF080 board interfaces with the host system through a custom board to board interface that implements x8 PCI Express lanes signaling as defined in the PCI...

Страница 29: ...ST_PWRGD_PS_R 3 5 TP_FW_SW_RAID_MODE 4 7 GND 5 9 PE0_TX_DP0 6 11 PE0_TX_DN0 7 13 GND 8 15 GND 9 17 PE0_TX_DP1 10 19 PE0_TX_DN1 11 21 GND 12 23 GND 13 25 PE0_TX_DP2 14 27 PE0_TX_DN2 15 29 GND 16 31 GND...

Страница 30: ...PE0_RX_DP3 41 32 PE0_RX_DN3 42 34 GND 43 36 GND 44 38 CLK_100M_IOP_DP 45 40 CLK_100M_IOP_D N 46 42 GND 47 44 LED_HDD_ACT_N 48 46 P3V3 49 48 P3V3 50 50 P3V3 Server Connector Pin Number RAID Module Pin...

Страница 31: ...drives of mixed capacity Cabling Small thin cables that do not restrict airflow and Shared connectors for multiple drives Redundant configuration 32 KB NVRAM and config on disk COD Enclosure manageme...

Страница 32: ...egrated RAID Module RMS2AF040 and RMS2AF080 Self Monitoring Analysis and Reporting Technology SMART support Detects up to 70 of predictable disk drive failures Monitors the internal performance of all...

Страница 33: ...irflow must be at least 200 linear feet per minute SFPM to avoid operating above the maximum ambient temperature The storage and transit environment conditions are Temperature range from 30 C to 80 C...

Страница 34: ...port for these devices will be determined as they become available For information on support for non hard drive devices see the Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Tested Hardware an...

Страница 35: ...to which data is being written to restore full redundancy for a virtual drive Unconfigured Bad Unconfigured Bad A physical drive on which the firmware detects an unrecoverable error the physical driv...

Страница 36: ...RMS2AF080 Hardware User s Guide RAID Controller Drive Limitations Only drives that comply with the SAS and SATA specification extensions are supported SAS Bus and ID Mapping Devices on the SAS bus ar...

Страница 37: ...esume To use drive roaming follow these steps 1 Turn off the power to the system all drives enclosures and system components Remove the power cord s 2 Remove the server cover For instructions see your...

Страница 38: ...Turn off the power to the system all drives enclosures and system components Remove the power cord s 3 Remove the server cover For instructions see your server system documentation 4 Disconnect the c...

Страница 39: ...s To help protect your computer system from sudden transient increases and decreases in electrical power use a surge suppressor line conditioner or uninterruptible power supply Be sure nothing rests o...

Страница 40: ...r To prevent static damage discharge static electricity from your body before you touch any of your computer s electronic components such as the microprocessor You can do so by touching an unpainted m...

Страница 41: ...l and disconnect all cables connected to I O connectors or ports on the back of the system 5 Provide some electrostatic discharge ESD protection by wearing an antistatic wrist strap attached to chassi...

Страница 42: ...aus der Steckdose bzw dem Netzger t um den Stromanschlu des Systems zu unterbrechen Die Stromkabel sind das Unterbrechungsger t zur Hauptstromquelle Die Steckdose in die das System gesteckt wird sollt...

Страница 43: ...mponenten zu vermeiden 6 Schalten Sie das System niemals ohne ordnungsgem montiertes Geh use ein Zur ordnungsgem en K hlung und L ftung mu die Geh useabdeckung immer wieder vor dem Einschalten install...

Страница 44: ...composants portez une bande antistatique pour poignet et reliez la la masse du syst me toute surface m tallique non peinte du bo tier 6 Ne faites pas fonctionner le syst me tandis que le bo tier est...

Страница 45: ...ca del equipo y ser de f cil acceso INSTRUCCIONES DE SEGURIDAD Cuando extraiga la tapa del chasis para acceder al interior del sistema siga las siguientes instrucciones 1 Apague todos los dispositivos...

Страница 46: ...sistema y bloqu elo para impedir que pueda accederse al mismo sin autorizaci n 5 Conecte todos los cables externos y los cables de alimentaci n CA al sistema Si el sistema ha estado en funcionamiento...

Страница 47: ...dal retro del sistema qualora ve ne fosse uno installato 2 Togliere e mettere in un posto sicuro tutte le viti delle coperture 3 Togliere le coperture Per il giusto flusso dell aria e raffreddamento d...

Страница 48: ...38 Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide...

Страница 49: ...Information Product Safety and EMC Compliance This Intel RAID Module has been evaluated for regulatory compliance as an Intel end system and is included as part of the end system certification For in...

Страница 50: ...40 Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide...

Отзывы: