4
Intel® Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User’s Guide
— No reboot necessary after expansion
— Load Balancing
•
Upgradeable Flash ROM interface.
•
Allows for staggered spin-up, hot-plug, and lower power consumption.
•
User specified rebuild rate (percent of system resources to use from 0-100%).
Caution:
Exceeding 50% rate may cause operating system errors due to waiting for
controller access.
•
Background operating mode can be set for Rebuilds, Consistency Checks,
Initialization (auto restarting Consistency Check on redundant volumes), Migration,
OCE, and Patrol Read.
Redundancy and Error Handling
•
SGPIO, In-band and out-band SES2 Enclosure management support.
•
Drive coercion (auto-resizing to match existing disks).
•
Auto-detection of failed drives with transparent rebuild. There must be disk activity
(I/O to the drive) for a missing drive to be marked as failed.
•
Auto-resume on reboot of initialization or rebuild (must be enabled before virtual
disk creation).
•
Smart initialization automatically checks consistency of virtual disks if there are five
or more disks in a RAID 5 array, which optimizes performance by enabling read-
modify-write mode. RAID 5 arrays of only three or four drives use Peer Read mode.
•
Smart Technology predicts failures of drives and electronic components.
•
Patrol Read checks drives and maps bad sectors.
•
Commands are retried at least four times.
•
Firmware provides best effort to recognize an error and recover if possible.
•
Failures are logged from controller and drive firmware, and SMART monitor.
•
Failures are logged in NVRAM, viewable from OS Event Log, Intel
®
RAID Web
Console 2; CIM, LEDs.
•
Access policy:
— RW: allow read and write I/O
— Read Only: allow read I/O only
— Blocked: deny read and write I/O
•
Redundancy through:
— Configuration stored in non-volatile RAM and on the drives (COD).
— Hot-swap support.
Содержание AXXRMS2AF040
Страница 4: ...iv Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide...
Страница 8: ...viii Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide...
Страница 10: ...x Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide...
Страница 16: ...6 Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide...
Страница 48: ...38 Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide...
Страница 50: ...40 Intel Integrated RAID Module RMS2AF040 and RMS2AF080 Hardware User s Guide...