On the File menu, click Programming File Generator.
2. Select Intel Agilex from the Device family drop-down list.
3. Select the configuration mode from the Configuration mode drop-down list. The current Intel Quartus Prime only
supports the RSU feature in the Active Serial x4 configuration mode.
4. On the Output Files tab, assign the Output directory and Name.
5. Select the
.rpd
output file type.
6. Click the Edit… button and assign the Start address for the factory update image in flash memory. You do not have to
create a separate partition for the factory update image. The factory update image typically includes the minimum
amount of logic necessary to successfully debug your design if your application image fails to load. Consequently the
Start address can be the sector boundary of unused space in flash memory. This Start address must match the starting
address of the target sector in flash memory. If the address is incorrect, the image does not load when the host tries to
use this image as a backup image.
Note: If unused space is not available, you can use an application image space other than application image 1. In this
case after the update operation completes you must restore the application image by writing the associated
application image (
.rpd
) to the application slot.
5. Remote System Update (RSU)
683673 | 2021.10.29
Intel
®
Agilex
™
Configuration User Guide
190