background image

18

Limited Warranty

INTEGRA LIFESCIENCES CORPORATION (“INTEGRA”) warrants to its authorized distributors 
and the original purchaser only that each new INTEGRA product is free from manufacturing 
defects in material and workmanship under normal use and service for a period of one (1) 
year (except as otherwise expressly provided as to accessory items) from the date of delivery 
by INTEGRA to the first purchaser, but in no event beyond the expiration date stated on any 
product labeling.

• 

Surgical instruments are guaranteed to be free from defects in material and workmanship 
when maintained and cleaned properly and used normally for their intended purpose.

• 

Any covered product that is placed by INTEGRA under a lease, rental or installment 
purchase agreement and that requires repair service during the term of such placement 
agreement shall be repaired in accordance with the terms of such agreement.

If any covered defect occurs during the warranty period or term of such placement agreement, 
the purchaser should communicate directly with INTEGRA’s home office. If purchaser seeks to 
invoke the terms of this warranty, the product must be returned to INTEGRA at its home office. 
The defective product should be returned promptly, properly packaged and postage prepaid. 
Loss or damage in return shipment to INTEGRA shall be at CUSTOMER’s risk. INTEGRA’s sole 
responsibility under this warranty shall be repair or replacement, at INTEGRA’s sole discretion 
at INTEGRA’s expense, subject to the terms of this warranty and applicable agreements.

IN NO EVENT SHALL INTEGRA BE LIABLE FOR ANY INCIDENTAL, INDIRECT, CONSEQUENTIAL 
OR PUNITIVE DAMAGES IN CONNECTION WITH THE ACQUISITION OR USE OF ANY INTEGRA 
PRODUCT. Further, this warranty shall not apply to, and INTEGRA shall not be responsible for, 
any loss arising in connection with the purchase or use of any INTEGRA product that has been 
repaired by anyone other than an authorized INTEGRA service representative or altered in any 
way so as, in INTEGRA’s judgment, to affect its stability or reliability, or which has been subject 
to misuse, negligence or accident, or which has been used otherwise than in accordance with 
the instructions furnished by INTEGRA. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN 
LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, AND OF ALL OTHER OBLIGATIONS 
OR LIABILITIES ON INTEGRA’S PART, AND INTEGRA NEITHER ASSUMES NOR AUTHORIZES 
ANY REPRESENTATIVE OR OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN 
CONNECTION WITH INTEGRA’S PRODUCTS.

INTEGRA DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED INCLUDING ANY 
IMPLIED WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE 
OR APPLICATION OR WARRANTY OF QUALITY AS WELL AS ANY EXPRESS OR IMPLIED 
WARRANTY TO PATIENTS. No warranty or guarantee may be created by any act or statement 
nor may this Standard Warranty be modified in any way, except as a result of a writing signed 
by an officer of INTEGRA. These limitations on the creation or modification of this warranty 
may not be waived or modified orally or by any conduct.

Integra Padgett dermatomes are intended for use in conjunction with Integra Padgett 
dermatome blades only. Accordingly, using another manufacturer’s blades in conjunction with 
an Integra Padgett dermatome will void the product warranty.

Содержание Padgett SB

Страница 1: ...Integra Padgett Model SB Slimline Dermatome...

Страница 2: ...line 3 Classifications 4 Specifications 4 Warnings 5 Precautions 6 International Symbols 8 Calibration 9 The Power Supply 10 How to Use the Model SB Slimline Dermatome 11 Maintenance And Servicing 13...

Страница 3: ...rmatome is delivered to you in a sturdy carry case with the power supply power supply cord 13 ft 3 96 m hand piece cord guard 2 3 and 4 inch 5 08 7 62 and 10 16 cm width clips screwdriver calibration...

Страница 4: ...ply 2 Hand Piece Cord 3 Hand Piece 4 Blade Clips 5 Calibration Guide 6 Screwdriver 7 Power Supply Wall Cord 2 3 4 5 1 Catalog Description Optional Accessories 3539 701 Dermatome hex nuts 2 pcs 3539 26...

Страница 5: ...DO NOT use in the presence of flammable anesthetics Specifications Maximum Graft Width SB 4 10 16 cm Input Voltage 100 250Vac Input Frequency 50 60Hz Output Volts 48Vac Output Current 1A Operating Tem...

Страница 6: ...zation and subsequent reuse will dull the blades and may result in cross contamination or impaired function of the product Sharpness of the blades is not guaranteed with repeated use Any blade once us...

Страница 7: ...Refer servicing to an authorized Integra Padgett Dermatome Repair Center Use Model SB hand piece with Model SB power supply and hand piece cord ONLY Prior to use visually inspect the dermatome hand p...

Страница 8: ...nnectors are to fit properly with their mating receptacles 4 Connect power supply power cord to wall receptacle and turn power supply switch on The indicator light on the power supply is to illuminate...

Страница 9: ...ol represents the international symbol for cutting This symbol represents the international symbol for Caution consult accompanying documents This symbol represents the international symbol for Altern...

Страница 10: ...n lies anywhere within the zone clearly marked on the calibration guide the dermatome is properly calibrated If the pin lies on the edge or outside the zone the dermatome should not be used and should...

Страница 11: ...light indicating that the dermatome is ready for use whenever the light is on Please note there may be up to a two second delay when the power switch is first activated before the green light illumina...

Страница 12: ...grasp the silver cap CAUTION Blades are single use ONLY DO NOT reuse blades The on off switch is on top of the hand piece and is operated with the thumb Push the switch forward for continuous mode Pu...

Страница 13: ...of the motor should be carried by the hand that holds the dermatome to maintain a reasonably light pressure between the cutting edge and the patient s body The instrument should be held at a 25 45 ang...

Страница 14: ...Service prior to returning product The product is required to be properly cleaned and sterilized before it is returned to the repair center with documentation verifying sterilization Failure to steri...

Страница 15: ...ting head and the edge of the guide bar Only remove the components as instructed below Further disassembly of the instrument is likely to cause permanent damage The dermatome contains no user servicea...

Страница 16: ...r dermatome performance Care must be taken in handling the motor housing in this state Dropping the motor housing or hitting the oscillating pin can cause damage that will result in the instrument bei...

Страница 17: ...les in the motor housing flange with the threaded studs of the cutting head Note that the thumbswitch on the motor housing is to be positioned on the top of the unit Tip the motor housing to create su...

Страница 18: ...re This is especially important when utilizing a flash sterilization cycle 100 Ethylene Oxide Sterilization Precondition the chamber to the specified exposure temperature and 55 relative humidity for...

Страница 19: ...ENT SHALL INTEGRA BE LIABLE FOR ANY INCIDENTAL INDIRECT CONSEQUENTIAL OR PUNITIVE DAMAGES IN CONNECTION WITH THE ACQUISITION OR USE OF ANY INTEGRA PRODUCT Further this warranty shall not apply to and...

Страница 20: ...ses Inc Pre Klenz is a trademark of Steris Corporation ASP Enzol and Sterrad are trademarks of Johnson and Johnson 2020 Integra LifeSciences Corporation All rights reserved Printed in USA PL 00196 Rev...