5. When the nut has been completely tightened, check each screen of all white, all red, all blue, all green, and
all black in order to confirm the freedom from any abnormality (chromaticity).
If any abnormality is perceived, adjust the sensor again (in the state of that screen) and check the resultant
conditions again.
6. Apply a screw lock agent to the area of the sensor and the nut.
METHOD OF ADJUSTMENTS
Note) At the time of adjustments and operation check under the condition that the top cover is open, use a
small-sized cooling fan or the like to avoid excessive temperature rise inside the set.
(The effect of cooling will be lowered if the top cover is removed. In case when the thermal protector
should operate as a result of temperature rise inside the set, pull out the power cord and wait until the
inside is cooled down. Restart is possible after confirming that the inside temperature has been suffi-
ciently low.)