Integra Codman DirectLink Скачать руководство пользователя страница 7

USA 800-654-2873 

 

n

  

888-980-7742 fax

Interna1 609-936-5400

  

n

  

+

609-750-4259 fax

integralife.com

United States, Canada, Asia, Pacific, Latin America

Availability of these products might vary from a given country or region to another, as a 
result of specific local regulatory approval or clearance requirements for sale in such country 
or region. 

 

n

  Non contractual document. The manufacturer reserves the right, without prior notice, to 

modify the products in order to improve their quality.

n

 Warning: Applicable laws restrict these products to sale by or on the order of a physician.

n

  Consult product labels and inserts for any indication, contraindications, hazards, warnings, 

precautions, and instructions for use.

For more information or to place an order, please contact:

DirectLink, Codman Microsensor, Codman, Integra and Intergra logo are registered 
trademarks of Integra LifeSciences Corporation or its subsidiaries in the United States 
and/or other countries. ©2019 Integra LifeSciences Corporation. All rights reserved.  
Printed in USA. 0M   0810530-2-EN

Содержание Codman DirectLink

Страница 1: ...Codman Microsensor ICP Transducer to a Patient Monitoring System Reference Signal Indicators Status Lights Arrow Button Patient Monitor Calibration Zero Button ICP Sensor Zeroing Output Connection To...

Страница 2: ...AMBER status light before continuing Press ARROW BUTTON until the 0 mmHg reference signal indicator illuminates Zero patient monitor per manufacturer s instructions PressARROWBUTTONuntilthe100mmHg ref...

Страница 3: ...ID AMBER prior to continuing Prepare the Codman Microsensor ICP Transducer for zeroing per the user manual Press and Hold the ZERO BUTTON for approximately 8 seconds Zeroing begins when amber status l...

Страница 4: ...if needed Press ARROW BUTTON and ZERO BUTTON simultaneously ACKNOWLEDGE FUNCTION to confirm sensor zero value and continue monitoring SOLID GREEN status light will illuminate after 4 seconds and ICP...

Страница 5: ...T to try again If problem persists patient monitor may be incompatible or DirectLink ICP Module needs to be replaced DURING USE A damaged cable or sensor may have been detected 1 Disconnect all cables...

Страница 6: ...k Cables are positioned away from other electrical equipment hold sensor steady and repeat zeroing process If problem persists it is likely a bad ICP Extension Cable ICP Sensor or electrical interfere...

Страница 7: ...r notice to modify the products in order to improve their quality n Warning Applicable laws restrict these products to sale by or on the order of a physician n Consult product labels and inserts for a...