Intec Turbo Force Скачать руководство пользователя страница 4

TURBO FORCE Instruction Manual

 | 

3

Symbols 

SYMBOL 

SYMBOL 

MEANING 

Danger 

Indicates an imminently hazardous situation, which, if not avoided, 
will result in death or serious injury. 

Warning 

Indicates a potentially hazardous situation, which, if not avoided, 
could result in death or serious injury. 

Caution 

Indicates a potentially hazardous situation, which, if not avoided, 
may result in minor or moderate injury. 

Safety First 

 

Disconnect all power cords prior to working on the equipment.  Failure to do so 
could result in injury or death. 

 

Never operate equipment with chain guard off. 

 

Never operate equipment with hopper in tilt-back mode. 

 

Never operate equipment while standing in water as electrical shock may result. 

 

Always use grounded extension cords when operating equipment. 

 

When working with insulation, always wear a long sleeve shirt, gloves and a hat. 
Wear goggles or safety glasses for eye protection.  Wear a mask for respiratory 
protection. 

 

Never put your hands into the hopper or machine outlet while the machine is 
operating. 

 

Keep tools and foreign objects out of the hopper. 

 

Never leave the machine unattended during operation. Disconnect all power to the 
machine when unattended. 

 

Never operate the equipment with the access panels off, possible 
injury may occur. 

 

Prior to use, inspect power cord and remote cord prior to ensure 
no damage exists.

netzerotools.com

netzerotools.com

Содержание Turbo Force

Страница 1: ...hine Intec Turbo Force Hp3 40010 00 Insulation Machine Canada Intec Turbo Force Hp3 40011 00 Insulation Machine Canada Intec Turbo Force Hp3 40012 00 Insulation Machine Canada Intec Turbo Force Hp3 40005 00 Insulation Machine Canada Intec Turbo Force Hp3 40006 00 Insulation Machine Canada Intec Turbo Force Hp3 40007 00 Insulation Machine Canada netzerotools com netzerotools com netzerotools com ...

Страница 2: ...tallation versatility all of our durable systems are made to maximize your profit generating potential Best in class Customer Service Total ease of use extends beyond your initial purchase of an Intec system to your evolving needs thru the entire lifecycle Both before and after the sale service is important to keep you running at peak operating capabilities Intec s technical team provides installa...

Страница 3: ...SYMBOLS 3 SAFETY FIRST 3 HOW THE SYSTEM WORKS 4 SYSTEM SET UP 5 SYSTEM OPERATION 7 MAINTENANCE 10 INTEC QUICK ACCESSTM IQA 11 TROUBLESHOOTING 13 SPECIFICATIONS 16 ELECTRICAL DRAWING 17 MAKING A CLAIM FOR DAMAGE OR LOSS 18 WARRANTY 19 netzerotools com netzerotools com ...

Страница 4: ... equipment with hopper in tilt back mode Never operate equipment while standing in water as electrical shock may result Always use grounded extension cords when operating equipment When working with insulation always wear a long sleeve shirt gloves and a hat Wear goggles or safety glasses for eye protection Wear a mask for respiratory protection Never put your hands into the hopper or machine outl...

Страница 5: ... in enhanced hopper utilization When using stabilized cellulose fiberglass or stone wool move the breaker bar up to its highest position or remove bar from system so product does not contact bar when being loaded into hopper Hopper The hopper contains the insulation being fed into the agitators Filters Ensure clean air is being used for blower intake and cooling Agitators The agitators condition t...

Страница 6: ...vy duty power cords each power source is required to be an independent circuit LED lights will glow indicating power to agitator and blower s circuit breakers Note If cannot find 3 independent circuits or desire is to use 1 blower vs 2 blowers then do not need to connect the second blower i e only 2 independent circuits required Suggested slide gate settings for desired applications Optional circu...

Страница 7: ...fiberglass or stone wool move the breaker bar up to its highest position or remove bar from system so it does not interfere with product when loading hopper 7 Load Insulation Remove packaging and load insulation Cellulose 1 Lift Loading Platform up 2 Rotate downwards to rest on system s handle Breaker Bar Breaker Bar Adjustment Settings 1 Set bag on platform remove plastic wrapping Be sure no plas...

Страница 8: ...ll the way around 2 Bend bag to break 3 Place bag on loading platform with open end facing towards a side not into the hopper Turn machine on Slice wrapper in direction shown to allow product to expand into hopper Keep plastic out of hopper netzerotools com netzerotools com ...

Страница 9: ...iliary Blower Cicuit Breaker in off position b Press Start Agitator button The blower has to be running for 3 4 seconds for the agitator to be able to start i Note The agitator will not start if the blower is not on ii Note The agitator has a delay of 3 5 seconds after BLOWER has been started iii Note Pressing the Stop Agitator button will stop the agitator only iv Note Pressing the Stop Blower bu...

Страница 10: ... Speed Setting to desired setting ranging from 100 to near 0 Note 1 To obtain maximum blower velocity and pressure place the Variable Speed control in the off position Placing the Variable Speed in the off position provides more power to your system s blowers when compared to having the Variable Speed on and Variable Speed Setting at 100 netzerotools com netzerotools com ...

Страница 11: ...ne s production Seal failure is the most common airlock assembly failure Seal failure prevents the airlock from holding the proper pressure Seal failure will reduce the machine s production A machine with seal failure will have air blow out of the airlock into the hopper reducing the amount of air exiting the machine outlet It is recommended to visually inspected seals each week to ensure proper r...

Страница 12: ...y efficient as possible so you can get back up and running in the quickest of manners is why Intec Quick Access was developed IQA TM was designed to further your efficiencies by reducing the time it takes to access critical system components From the revolutionary tilt back design providing access to the airlock hopper agitator and airlock motors and blowers to the quick access chains electrical c...

Страница 13: ...nel provides access to the electronics controlling your TURBO FORCE IQA Filters Simply slide filter from holder use compressed air or knock filter on a hard surface to remove contaminants and replace filter in the appropriate holder on machine IQA Slide Gate Settings Pull the pin slide gate to recommended setting and you are on your way towards obtaining appropriately conditioned insulation for th...

Страница 14: ...on position Auxiliary Blower s circuit breaker needs to be in the on position Place Auxiliary Blower s circuit breaker in the on position Variable Speed switch is in the neutral position Place Variable Speed switch in either the off or on position Blower contactor overload activated Let system cool If happens often contact Intec for settings Worn brushes in blower motor Have a qualified technician...

Страница 15: ...bute insulation material inside hopper Airlock seal is worn Inspect airlock seals for cuts and wear Have a qualified technician replace airlock seals Airlock has an obstruction preventing insulation from exiting Disconnect electrical power remove obstruction Variable Speed is on and Variable Speed Setting is below 100 yet still a lot of air flow Auxiliary blower is on Place the Auxiliary Blower Ci...

Страница 16: ...ires 115V 15amp separate circuit for agitator and each blower Extension cord gauge is too small Use a 12 3 heavy duty i e SJ300V extension cord with 115V Chain is not aligned with sprockets Disconnect electrical power Have a qualified technician realign chain and sprockets Machine makes a banging noise when agitator is operating Chain is loose Disconnect electrical power Have a qualified technicia...

Страница 17: ...ower 115 VAC 14 3 amp single stage Agitator Motor HP 115VAC 7 8 amp Airlock Motor HP 115VAC 7 8 amp Power Requirements 2 115VAC 60 Hz 15 amp circuits for standard 3 115VAC 60 Hz 15 amp circuits for hP3 854mm 1311mm 1562mm 1356mm 394mm 918mm netzerotools com netzerotools com ...

Страница 18: ...TURBO FORCE Instruction Manual 17 Electrical Drawing netzerotools com netzerotools com ...

Страница 19: ...propriate freight carrier When items leave our warehouse the shipper assumes responsibility It is the responsibility of the consignee to file a claim Proper documentation is necessary to support the claim Please inspect all items properly prior to signing for them 2 Items received not correct A Incorrect items received Contact Intec Customer Service B Incomplete order received not backordered Cont...

Страница 20: ...e of factory shipment c This Warranty shall not apply to any MACHINE or component part which in the opinion of the MANUFACTURER has been altered subject to misuse negligence accident or operated beyond factory rated capacity All requested Warranty work should be performed at MANUFACTURER s factory or by an Authorized Factory Service Facility Failure to have the Warranty work done at MANUFACTURER S...

Отзывы: