TURBO FORCE Instruction Manual
|
13
TroubleShooting
Problem
Likely Cause
Remedy
Ready Light does not light up.
Power cord connection is loose.
Ensure appropriate power cord
connection at machine.
Ensure appropriate power cord
connection at power source.
Power cord not connected at
machine or power source.
Connect power cord.
Emergency stop button has not
been pulled out.
Pull out emergency stop bottom.
Machine’s blower or agitator
circuit breaker(s) has tripped.
Push to reset circuit breaker(s).
Circuit breaker at power source
as tripped.
Reset circuit breaker.
Electrical system may have a
loose wire.
Have the system inspected by a
qualified technician.
Blower does not run.
Primary Blower’s circuit breaker
needs to be in the ‘on’ position.
Place Primary Blower’s circuit
breaker in the ‘on’ position.
Auxiliary Blower’s circuit breaker
needs to be in the ‘on’ position.
Place Auxiliary Blower’s circuit
breaker in the ‘on’ position.
Variable Speed switch is in the
neutral position.
Place Variable Speed switch in
either the ‘off’ or ‘on’ position.
Blower contactor overload
activated.
Let system cool. If happens
often, contact Intec for settings.
Worn brushes in blower motor.
Have a qualified technician
replace blower brushes or
replace blower motor.
Agitator does not run.
Blower has to be on for agitator
to come on.
Turn blower on.
Blower has not been on for 3-4
seconds.
Agitator time delay requires
blower to be on for 3-4 seconds
for agitator to activate.
Agitator circuit breaker needs to
be in the ‘on’ position.
Place Agitator circuit breaker in
the ‘on’ position.
Foreign material causing jam in
hopper.
Remove power cords, clear jam,
and restart system.
Blower contactor overload
activated.
Let system cool. If happens
often, contact Intec for settings.