Intec FORCE 5150 Скачать руководство пользователя страница 8

 

Instruction Manual

 | 

7

 

 

T:  303-833-6644 

or

 800-666-1611 

www.inteccorp.com 

Original Language - English 

Quick Access Airlock Door:  By removing six bolts, the Quick Access Airlock Door can be opened on its 
hinge to enable quick change of the airlock seals to ensure appropriate air sealing and peak 
production.   
 

Set up and Operation 
 
      
 
 

System Set-Up:

  

  

INITIAL OPERATION 
During initial operation, install the fresh air inlet for the HONDA GX390. 
 
A.

 

Engine Fresh Air Inlet mounting plates:  These mounting plates enable 
you to connect the 10” hose provided with your system (and connected 
to the HONDA engine) to a fresh, clean air source outside of your 
vehicle.  Recommendation is to: 

 
a.

 

Cut a 10” diameter hole into the side wall or floor of your truck / 
trailer.  NOTE:  be sure to cut in a non-load bearing area. 

b.

 

Mount the Outside Plate (on the outside of the truck) and Inside 
Plate (on the inside of the truck) – sandwiching the wall or floor -- with four nuts.   
 
 
 
 
 
 
 
 
 
 

c.

 

Hose Ring:  The Hose Ring will mount to the Inside Plate.   

 

 

Inside Plate 

Outside Plate 

Содержание FORCE 5150

Страница 1: ...tion Manual Insulation blowing machine Original Language English Intec 4040 Kodiak Court Frederick CO 80504 USA T 303 833 6644 Web www inteccorp com Email info inteccorp com T 800 666 1611 Rev Date 20...

Страница 2: ...rs to truck mount units with increased production rates and installation versatility all of our durable systems are made to maximize your profit generating potential VORTEC VACUUMS Powered by Gas or E...

Страница 3: ...e of Contents INTRODUCTION 1 SYMBOLS 3 SAFETY FIRST 3 HOW THE SYSTEM WORKS 4 System Set Up 7 System Operation 9 Reprogramming Intec s Long Range Transmission wireless remote 10 MAINTENANCE 11 TROUBLES...

Страница 4: ...hanical issues or if machine is vibrating extensively additional damage can potential safety issues can occur Never operate equipment while standing in water as electrical shock may result Proper Prot...

Страница 5: ...in processing the insulation while moving towards the airlock column Once in the column insulation is processed additionally by the shredder bar It then moves through the slide gate and into the airl...

Страница 6: ...rm acts as a shelf to support the bag of insulation being loaded into the hopper Hopper The hopper contains the insulation being fed into the agitators Engine Fresh Air Inlet Hose The Engine Fresh Air...

Страница 7: ...need exists to remove foreign materials that have become entangled in the shredder bars CAUTION Always ensure machine is off and cannot be restarted when accessing the shredder box Slide Gate The sli...

Страница 8: ...et for the HONDA GX390 A Engine Fresh Air Inlet mounting plates These mounting plates enable you to connect the 10 hose provided with your system and connected to the HONDA engine to a fresh clean air...

Страница 9: ...fasten the open side of the Fresh Air Inlet to the 10 diameter hose Upon completion you will now have fresh clean air from outside your vehicle used to cool the HONDA engine EACH TIME YOU UTILIZE BLOW...

Страница 10: ...0 ELECTRICAL SYSTEM TO FUNCTION APPROPRIATELY 2 Rotate the ROTARY CONTROL SELECTOR SWITCH to the desired method to operate system a WIRELESS REMOTE i Operate system thru Intec s Long Range Transmissio...

Страница 11: ...itter from jacket b Remove small piece of black tape on back of transmitter c Stick a paperclip into the small hole and hold button down for 7 to 14 seconds to enable wireless transmitter to select a...

Страница 12: ...r and exterior of the machine weekly by wiping with a rag and or blowing with compressed air this will help maintain the longevity of the mechanical components in addition to the system s finish The m...

Страница 13: ...ed to visually inspected seals each week to ensure proper running condition Replace airlock seals if a cut or tear is evident Airlock seals should be replaced every 300 hours of operation or once per...

Страница 14: ...oes not run HONDA is not running at full throttle Move throttle to the full HIGH position Auxiliary Blower s circuit breaker needs to be in the on position Place Auxiliary Blower s circuit breaker in...

Страница 15: ...stop in then remove obstruction Variable Speed is on and Variable Speed Setting is below 100 yet still a lot of air flow Auxiliary blower is on Place the Auxiliary Blower Circuit Breaker in the off po...

Страница 16: ...open to allow for radio frequency waves to easily enter and access the receiver in the blowing machine Antenna in the down position Position the antenna into a straight position vs the 90 degree bend...

Страница 17: ...4 or 800 666 1611 www inteccorp com Original Language English Specifications Weight FORCE 5150 825 lbs 375 kg Hopper size 31 cubic feet Blowers Quantity 2 115 VAC 13 4 amp two stage for each blower Mo...

Страница 18: ...Instruction Manual 19 T 303 833 6644 or 800 666 1611 www inteccorp com Original Language English Electrical Drawings...

Страница 19: ...ility It is the responsibility of the consignee to file a claim Proper documentation is necessary to support the claim Please inspect all items properly prior to signing for them 2 Items received not...

Страница 20: ...rantied for a period of ninety 90 days from date of factory shipment c This Warranty shall not apply to any MACHINE or component part which in the opinion of the MANUFACTURER has been altered subject...

Отзывы: