INSYS Powerline GP
Assembly
27
Disconnecting the pilot line
The device is mounted to the DIN rail.
The power supply is connected and switched off.
1.
Disconnect the pilot signal source from the terminals 5 ("Pilot In
–
")
and 6 ("Pilot In +").
2.
Disconnect the charging socket from the terminals 7 ("Pilot Out
–
")
and 8 ("Pilot Out +").
The INSYS Powerline GP is now disconnected from the pilot line.
Disconnecting the power supply
The device is mounted to the DIN rail.
The power supply is connected and switched off.
1.
Disconnect the ground lead of the power supply from the terminal
"GND".
2.
Disconnect the plus pole of the power supply from the terminal for
the power supply.
The INSYS Powerline GP is disconnected from the power supply.
Removing the device from the DIN rail
How to uninstall the INSYS Powerline GP from a DIN rail in a switch
cabinet:
You will need a Phillips screwdriver with a 4.5 mm blade.
The power supply of the switch cabinet is switched off and secured against
being switched on accidentally.
All cables at the INSYS Powerline GP are disconnected.
Danger!
Exposed electrical components!
Risk of fatal injury from electric shock.
Prior to the installation, switch the power supply of the
cabinet off and secure it against being switched on again.