![Instron 2630-100 Series Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/instron/2630-100-series/2630-100-series_reference-manual_2070120033.webp)
Attaching the Extensometer
33
Product Support:
www.instron.com
1. Hold the extensometer with the Gauge
Length cone-latch engaged and
position the knife edges against the
test specimen.
2. Holding a specimen clamp, straddle
the specimen above the knife edges of
the extensometer.
3. Press the clamp against the specimen
to compress the spring loaded plunger
and hook the specimen clamp on the
knife edges.
Ensure that the knife edge seats
properly in the specimen clamp notch
pivot.
Figure 11. Specimen Attachment Using the
Variable Pressure Specimen Clamps and
Pivot Knife Edges
Notch Pivot
Notch Pivot Slots Pointing Outwards
from the Gauge Length
Pressure
Adjuster
Ring