background image

SwitchLinc Dimmer 1000W User’s Guide 

 

Page 15 of 36 

 

Unlinking a Controlled INSTEON Device from SwitchLinc Dimmer 

If you are no longer going to use an INSTEON Device that has previously been linked to SwitchLinc 
Dimmer, it is very important that you unlink it, because otherwise SwitchLinc Dimmer will retry any 
commands intended for the unused INSTEON Device, thus slowing down your system. 

1.  Set SwitchLinc Dimmer to 

Linking Mode

 by pressing and holding the 

Paddle Top

 for 10 seconds 

until the top LED in the LED Bar begins blinking slowly and the controlled light flashes. 

2.  Set SwitchLinc Dimmer to 

Unlinking Mode

 by pressing and holding the 

Paddle Top

 

again

 for 10 

seconds until the controlled light flashes again. 

3.  Follow the same method given above that you used to link your INSTEON Device to unlink it.  On 

most INSTEON Devices, you just push an 

ON Button

 for 10 seconds or a 

SET Button

 for 3 seconds. 

4.  Go back to the SwitchLinc Dimmer that you placed in Unlinking Mode.  If linking was successful, the 

top LED in its LED Bar will not be blinking but will remain steadily on. 

Creating an INSTEON Scene 

INSTEON Scenes let you activate dramatic lighting moods with the press of just one button.  INSTEON 
Scenes are very easy to set up – just link more than one INSTEON Device to SwitchLinc Dimmer.  Then, 
when you press either the Paddle Top or Paddle Bottom on SwitchLinc Dimmer, all of the INSTEON 
Devices linked in the scene will respond as a group.  You can link multiple INSTEON Devices to multiple 
of INSTEON Controllers. 

To add an additional INSTEON Device to a scene controlled by SwitchLinc Dimmer, simply follow the 
same procedure as above in 

Linking SwitchLinc Dimmer to a Controlled INSTEON Device

.  To remove an 

INSTEON Device from a scene, see 

Unlinking a Controlled INSTEON Device from SwitchLinc Dimmer

TIP 

 
You can avoid having to hold SwitchLinc Dimmer’s Paddle Top down for 10 seconds for each 
INSTEON Device in a scene by placing SwitchLinc Dimmer in 

Scene Setup Mode

, also called 

Multilink Mode

1.  Set SwitchLinc Dimmer to Scene Setup Mode by 

pressing and holding the 

Paddle Top

 for 10 

seconds, then pressing the 

SET Button

 at the 

bottom of the paddle.  SwitchLinc Dimmer’s top 
LED in the LED Bar will blink slowly. 

 

 

2.  Follow the linking method given above for the INSTEON Device you want to include in the scene.  

On most INSTEON Devices, you just push an ON Button for 10 seconds or a SET Button for 3 
seconds.  SwitchLinc Dimmer will flash its controlled light to confirm linking, and the top LED in its 
LED Bar will continue to blink slowly. 

3.  On some INSTEON Devices, you may be able to set up additional features, such as On-Levels or 

Ramp Rates at this time. 

4.  Continue Steps 2 and 3 for any additional INSTEON Devices you want to link to the scene. 

5.  When you are finished linking INSTEON Devices to SwitchLinc Dimmer, complete Scene Setup by 

pressing the 

Paddle Top

 (actually, 

any

 button press will terminate Scene Setup).  The top LED in 

SwitchLinc Dimmer’s LED Bar will stop blinking and remain steadily on.  You have about 4 
minutes of inactivity before SwitchLinc Dimmer’s Scene Setup Mode times out automatically. 

Содержание SwitchLinc 2476DH

Страница 1: ...SwitchLinc Dimmer 1000W INSTEON Enabled Dimmer Switch For models 2476DH SwitchLinc Dimmer 1000W...

Страница 2: ...vel 18 Setting the Ramp Rate 19 Locking In a Remote Controlled On Level and Ramp Rate 19 Locking In a Local On Level and Ramp Rate 19 HOW TO CROSS LINK MORE THAN ONE SWITCHLINC DIMMER 20 Cross Linking...

Страница 3: ...N 30 Understanding Why an INSTEON Network Is Reliable 30 Further Enhancing Reliability 30 Using Smarthome s Access Point to Upgrade Your INSTEON Network 30 About INSTEON and X10 31 TROUBLESHOOTING 32...

Страница 4: ...NSTEON also works with legacy X10 devices An INSTEON home grows in value with every INSTEON device you add making life more convenient safe and fun Key SwitchLinc Dimmer Features After installation se...

Страница 5: ...m this installation To reduce the risk of overheating and possible damage to other equipment use SwitchLinc Dimmer to control 110V incandescent lamps only Dimming an inductive load such as a fan or tr...

Страница 6: ...inc Dimmer may feel warm during operation This includes the exaggerated mounting fins which are designed to aid in heat dissipation The amount of heat generated is within approved limits and poses no...

Страница 7: ...ecting them 6 If you are installing SwitchLinc Dimmer into a multi way circuit where more than one switch controls the same load follow the instructions in the section Installing SwitchLinc Dimmer in...

Страница 8: ...und are circuits that are 4 way or above You can use SwitchLinc Dimmers to replace switches in multi way circuits that are already wired in or you can use them to create virtual multi way circuits whe...

Страница 9: ...ER number 2 the black one you will convert to a LINE wire In the junction box where the SwitchLinc Secondary is connect TRAVELER 2 to the existing LINE and also to the SwitchLinc Secondary s LINE wire...

Страница 10: ...r greater some of the switches will have four wires c Disconnect the wires from the old switches If the wires cannot be detached by unscrewing them cut the wires where they enter the switch then strip...

Страница 11: ...wire to ensure that it won t connect to anything 5 Connect the SwitchLinc Secondary s NEUTRAL Wire Locate the group of NEUTRAL wires usually white in the rear of the box The old switch should not hav...

Страница 12: ...lled the LOAD wire is commonly red In the same junction box there will also be the two TRAVELER wires from the first box often both in the same cable sheath Identify the one TRAVELER wire black that y...

Страница 13: ...ghts those extra switches will have four wires connected to them Two of the wires are TRAVELERS from the preceding switch and the other two are TRAVELERS to the next switch in the chain You will be co...

Страница 14: ...nc Dimmer Press and hold the Second SwitchLinc Dimmer s Paddle Top for 10 seconds then release To confirm linking the Second SwitchLinc Dimmer will blink the top LED in its LED Bar and flash the light...

Страница 15: ...multiple INSTEON Devices to multiple of INSTEON Controllers To add an additional INSTEON Device to a scene controlled by SwitchLinc Dimmer simply follow the same procedure as above in Linking SwitchL...

Страница 16: ...will flash the light that it is wired to once and begin blinking the top LED in its LED Bar B ControLinc Tabletop Controller Choose the ON OFF Button Pair you want to use for controlling SwitchLinc D...

Страница 17: ...er Press and hold the OFF Button of the ON OFF Button Pair you used for controlling SwitchLinc Dimmer for 10 seconds To confirm that it is in Unlinking Mode ControLinc s Status LED will begin blinking...

Страница 18: ...separate On Levels and Ramp Rates for each button on each Controller that it is linked to These On Levels and Ramp Rates can all be the same or they can be different You establish an On Level and Ramp...

Страница 19: ...lly just the same as linking Just follow the instructions in the section Linking an INSTEON Controller to SwitchLinc Dimmer above Linking an INSTEON Controller to SwitchLinc Dimmer restores the previo...

Страница 20: ...OFF status and brightness level on the LED bar of the other switches it has been cross linked to Cross Linking in a Multi Way Circuit using Multi Link Mode For more than two switches multi link mode...

Страница 21: ...above 4 If you are using SwitchLinc Dimmer to control any INSTEON Devices other than the light it is wired to unlink those Devices from SwitchLinc Dimmer See Unlinking a Controlled INSTEON Device from...

Страница 22: ...ep before SwitchLinc Dimmer s Linking Mode times out automatically 3 Once SwitchLinc Dimmer has received the X10 Address three times SwitchLinc Dimmer will confirm that it has set its Primary X10 Addr...

Страница 23: ...X10 Resume Dim is enabled SwitchLinc Dimmer will remember the last brightness level to which it was set Then when an X10 ON command is received from an X10 Controller the light will go to the remember...

Страница 24: ...r s brightness using its paddle or any Controller If you skip this step the current On Level will be used 4 Send the following X10 Address sequence to lock in the new On Level 5 SwitchLinc Dimmer will...

Страница 25: ...dress and On Level 1 Using an X10 Controller send the CLEAR Sequence 2 Set the On Level for the X10 Scene Address by adjusting SwitchLinc Dimmer s brightness using its paddle or any Controller If you...

Страница 26: ...o adjust SwitchLinc Dimmer s brightness so it corresponds to the Ramp Rate you want in the table below If you use SwitchLinc Dimmer s paddle and you are careful you can still set one of 32 brightnesse...

Страница 27: ...ress and hold the Paddle Bottom to gradually dim your light from whatever brightness it currently has to full OFF Paddle Tap Double Tap Press and Hold Top Ramp to On Level Fast ON Brighten Bottom Ramp...

Страница 28: ...s How to Change Paddle and LED Colors You can remove the front paddle and trim frame assembly before or after SwitchLinc Dimmer is installed During the changeover process the power and the load may re...

Страница 29: ...e frame Using only finger pressure snap the light pipe into the frame 7 If both light pipes are installed correctly they will stick straight out from the back of the frame If installed incorrectly the...

Страница 30: ...come signals getting weaker is to increase the coverage of the mesh network by introducing more INSTEON devices It is possible that some audio video products computers power strips or other electrical...

Страница 31: ...you can turn on or turn off when you set the X10 Address for the product If turned on the BoosterLinc technology may interfere with INSTEON KeypadLinc 6 with Integrated Dimmer 12073W 12073WB and 12073...

Страница 32: ...inking to or working with an INSTEON Controller or Device The INSTEON signal may be too weak Make sure you are not experiencing interference with older X10 BoosterLinc technology Upgrade to INSTEON Bo...

Страница 33: ...ress by following the instructions in the section Setting the X10 Primary Address I m having difficulty performing advanced X10 programming The X10 MNOP house and unit codes were sent in the wrong ord...

Страница 34: ...uit Support One SwitchLinc Dimmer controls load Cross Link any number of SwitchLinc Dimmers or other INSTEON Controllers Setup Memory Non volatile EEPROM INSTEON Features INSTEON Addresses 1 hard code...

Страница 35: ...de rating Heat Dissipation Four heat dissipation fins integrated into SwitchLinc Dimmer body Individual fins can be permanently detached from switch if fins interfere with installation Removal of each...

Страница 36: ...y package the product with the RA clearly printed on the outside of the package and send the product along with all other required materials to SmartLabs Inc ATTN Receiving Dept 16542 Millikan Ave Irv...

Отзывы: