LampLinc Owner’s Manual  

 

Page 10 of 19 

 

ADVANCED FEATURES  

Using LampLinc as a Phase Bridger (for LampLinc (Dual-Band) only) 

Use the following procedure to test that the phases have been bridged: 
1)  Install additional dual-band INSTEON devices if they aren’t already installed  
2)  Start Phase Bridging Detection Mode by tapping the Set button on LampLinc four times quickly 

LampLinc 

will 

begin beeping continuously and the Status LED 

will 

be solid green 

Depending on its current state, the load 

may 

turn on or flash once 

Phase Bridging Detection Mode will time out after 4 minutes of inactivity.  

3)  Check the LED behavior of your other dual-band devices to see if they are on the opposite phase 

If at least one of your other dual-band device LEDs is blinking green or is bright solid white or blue, the 
device is on the opposite phase. Continue to step 4. 

 

If none of your dual-band devices exhibit the behavior above, they are on the same electrical phase. 
Try one or both of the following: 

 

Move a dual-band device to another location until it exhibits the desired behavior 

 

Follow steps 2 and 3 with your other dual-band devices to see if they are bridging the phases  

4)  Tap the Set button on LampLinc to exit Phase Bridging Detection Mode  

LampLinc 

will 

stop beeping and the Status LED 

will 

remain solid green if the load is on or turn solid red 

if it is off 

 

Enabling/Disabling Load Sensing 

Load Sensing allows you to manually turn on the load plugged into LampLinc by using the switch on the load 
itself, without sending a command from an INSTEON or X10 controller. When the load is in the off state (with 
Load Sensing enabled), LampLinc will “sense” that you are trying to turn it on with its built-in switch. When 
LampLinc senses this, it will turn on the load automatically. 
If LampLinc is used to control other INSTEON devices, those devices will also respond appropriately when the 
load is turned on with its built-in switch. 

CAUTION

: With Load Sensing enabled, some lamps have been known to turn on LampLinc after you have 

turned it off. Please use this feature with caution. 
By default, Load Sensing is 

enabled 

on LampLinc.  

Disable Load Sensing

 

 

1)  Press & hold the Set button on LampLinc until it beeps (3 seconds)  

The LampLinc Status LED 

will 

begin blinking green  

2)  Double-tap the Set button on LampLinc  

LampLinc 

will 

beep and its Status LED 

will 

stop blinking and turn on solid green if the load is on or solid 

red if it is off

 

3)  Test that Load Sensing has been disabled by turning the load on and off from its built-in switch  

The load 

will 

not respond 

 

Enable Load Sensing 

1)  Press & hold the Set button on LampLinc until it beeps (3 seconds) 

The LampLinc Status LED 

will 

begin blinking green

 

2)  Triple-tap the Set button on LampLinc 

LampLinc 

will 

beep and its Status LED 

will 

stop blinking and turn on solid green if the load is on or solid 

red if it is off

 

3)  Test that Load Sensing has been enabled by turning the load on and off from its built-in switch 

The load 

will 

turn on and off  

Содержание Insteon LampLinc 2457D2X (Single-Band)

Страница 1: ...LampLinc INSTEON Plug In Lamp Dimmer Module 2 Pin Model 2457D2 Dual Band 2457D2X Single Band ...

Страница 2: ...nc from an INSTEON Controller 9 CREATING INSTEON SCENES 9 ADVANCED FEATURES 10 Using LampLinc as a Phase Bridger for LampLinc Dual Band only 10 Enabling Disabling Load Sensing 10 Multi Linking and Multi Unlinking 11 Cross Linking INSTEON Devices 12 Restoring Power to LampLinc 13 Resetting LampLinc to its Factory Default Settings 13 X10 PROGRAMMING OPTIONS 14 Setting the X10 Address 14 Removing the...

Страница 3: ... devices in minutes X X Controls all standard incandescent lamps and other plug in devices up to 300 Watts X X Responds to and controls other INSTEON devices as well as X10 devices X X Indicates INSTEON setup mode activity and operational states with a dual color Status LED and beeper X X Dims the load up to 32 brightness levels X X Changes brightness at 32 Ramp Rates X X Load Sensing easily disab...

Страница 4: ... a unique INSTEON ID so unless neighbors or would be hackers have access to your particular device s INSTEON ID they won t be able to control your home even if they are using similar products INSTALLATION Preparing to Install LampLinc CAUTION Read and understand these instructions before installing and retain them for future reference LampLinc is intended for installation in accordance with the Na...

Страница 5: ... Double tap Press hold Up Ramp to On Level Full bright instantly Brighten until released Down Ramp to Off Full off instantly Dim until released Status LED and Beeper Activity Status LED Activity Status LED Activity LampLinc Status Setup Mode Load is on Solid green Phase Bridging Detection Mode has been initiated Solid red Load is off Linking Mode Blinking green Phases have been bridged if used as ...

Страница 6: ...evels and Ramp Rates are locked in separately and can be set up in any order When you do the lock in the most recently set On Level and Ramp Rate are locked in together Setting the On Level 1 Use the Up and Down buttons on LampLinc to adjust the load to the desired brightness 2 Once the desired brightness has been achieved tap the Set button on LampLinc LampLinc will beep and the load will flash o...

Страница 7: ...10 8 5 Less than 1 9 0 NOTE If the load is ramping to less than full brightness then the time it will take will be proportionately less For instance if the load is going to half brightness the time it will take for a given Ramp Rate will be halved 2 Once you reach the desired brightness Ramp Rate double tap the Set button on LampLinc LampLinc will beep and the load will flash once 3 Test the Ramp ...

Страница 8: ...ce 4 Confirm that Linking was successful by tapping the Up and Down buttons on LampLinc The Responder will respond appropriately 5 If you wish to Link multiple Responders to the same LampLinc either repeat steps 1 4 with each Responder or see Multi Linking and Multi Unlinking Unlinking an INSTEON Responder from LampLinc If you are no longer going to use an INSTEON Responder that has been Linked to...

Страница 9: ...llers will retry any commands repetitively thus slowing down the system The following will work for the most common INSTEON devices 1 Set the Controller to Unlinking Mode For most Controllers press hold an On or Scene button for 10 seconds twice or the Set button for 3 seconds twice You will have 4 minutes to complete the next step before Unlinking Mode automatically times out 2 Press hold the Set...

Страница 10: ...ad Sensing allows you to manually turn on the load plugged into LampLinc by using the switch on the load itself without sending a command from an INSTEON or X10 controller When the load is in the off state with Load Sensing enabled LampLinc will sense that you are trying to turn it on with its built in switch When LampLinc senses this it will turn on the load automatically If LampLinc is used to c...

Страница 11: ...not have a Set button tap the same On or Scene button you used to put the Controller into Linking Mode 6 Test that the INSTEON scene is working properly by tapping the button you just Linked to on the Controller Multi Unlinking Multi Unlinking Mode can be used to quickly remove devices from an INSTEON scene You may remove as many of the Linked Responders from the scene as you would like The follow...

Страница 12: ...the Set button for 3 seconds Upon successful completion each device will now track the on off status of the load and the LEDs of the devices it has been Cross Linked to Cross Linking More Than Two INSTEON Devices When you have more than two devices controlling a single load you can the Multi Linking feature to Link one device to multiple others in one step To Cross Link all the devices together yo...

Страница 13: ... clear the LampLinc memory of all INSTEON Links programmed On Levels and Ramp Rates X10 addresses etc 1 If you are using a Controller to control LampLinc be sure to Unlink it from the Controller See Unlinking LampLinc from an INSTEON Controller 2 If you are using LampLinc to control any Responders Unlink them from LampLinc See Unlinking an INSTEON Responder from LampLinc 3 Unplug LampLinc for abou...

Страница 14: ... Status LED will turn on solid green if the load is on or solid red if it is off Removing the X10 Address If you are no longer going to control LampLinc with an X10 address it is very important that you Unlink it Otherwise LampLinc will still respond to X10 commands and may cause LampLinc to turn on by itself 1 Set LampLinc to Linking Mode by pressing holding the Set button until it beeps 3 second...

Страница 15: ...e command up to five times While using at least one dual band device is required when using an RF only device at least two dual band devices are recommended in any INSTEON network to ensure reliable communication across two phase home wiring systems For larger applications it is recommended to install at least one dual band device for every 750 1 000 square feet Search for dual band INSTEON device...

Страница 16: ...ise filter 1626 10 to filter electrical noise and minimize signal attenuation Unlink any unused Responders from the Controller HINT If you are using home automation software you can easily check scene membership and eliminate unnecessary Links LampLinc is taking a long time to respond to a Controller The Controller may be sending commands to a Responder that is no longer in use Commands for the un...

Страница 17: ...y turns off when I tap a button on the Controller but I can brighten or dim it The On Level may be set to very dim or fully off Re Link LampLinc to the Controller at a brighter On Level See Linking an INSTEON Controller to LampLinc The load doesn t appear to turn on right away The Ramp Rate may be set too slow Set a shorter Ramp Rate See Setting the Ramp Rate Unplug LampLinc for 10 seconds and the...

Страница 18: ...aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radiolectrique subi mme si le brouillage est susceptible d en compromettre le fonctionnement The digital circuitry of this device has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limit...

Страница 19: ...her oral or written express or implied including any warranty or merchantability or fitness for a particular purpose Any implied warranty including any warranty of merchantability or fitness for a particular purpose which may not be disclaimed or supplanted as provided above shall be limited to the two year of the express warranty above No other representation or claim of any nature by any person ...

Отзывы: