721U0901
Rev
03
-
Product
specifications
are
subject
to
change
4
Page
Toll Free (N.A.): 1.800.267.9111
Telephone: 1.613.592.4642
Email: [email protected]
www.instantel.com
Warranty
Instantel products come with a one-year warranty. Monitoring units and sensors will have the warranty extended for a second year if they are returned
to the Instantel factory for service and calibration within 30 days of the ‘Next Calibration’ date printed on the calibration label located on the product.
If within a period of one year from the date of shipment to a customer, the instrument fails to perform in accordance with Instantel’s published
specifications and the operator’s manual, due to a defect in materials or workmanship, it will be repaired or replaced at Instantel’s option, free of
charge. This warranty is void if the equipment has been dismantled, altered or abused in any way. This warranty is nontransferable.
This warranty does not include any implied warranty of functionality for a particular purpose. Instantel assumes no responsibility for damages of any
description resulting from the operation or use of its products. Since it is impossible to anticipate all of the conditions under which its products will
be used either by themselves or in conjunction with other products, Instantel cannot accept responsibility for the results unless it has entered into a
contract for services which clearly define such an extension of responsibility and liability.
Any shipments returned directly to Instantel Inc. must have our prior approval and all packages must display the Return of Material Authorization
(RMA) number issued by Instantel. Shipping charges to Instantel’s plant will be paid by the customer and those for return to the customer will be
paid by Instantel.
To protect your warranty, you must complete and return a Warranty Registration Certificate, or complete the online Warranty Registration Form,
within ten days of purchase. Products will be assumed out of warranty if there is no warranty card on file at Instantel. Retain this portion and the
proof of purchase for your records.
EC Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take
adequate measures.
Physical Installation
1. Connect the Remote Alarm Controller to the Auxilliary connector on the monitoring unit. To increase the distance
between the two devices make use of the appropriate extension cable as referenced by unit and part number in
the previous table.
2. The output available on the terminal block is only a switch. You must supply external power to drive the load.
When using an external warning device, the common terminal is the ground or minus side of the external
load-power source combination. Normally, one side of the external load connects to the positive side of the
power supply. The negative side of the power supply connects to the common terminal.
Micromate Alarm Setup
1. Press the
Setup
key to access the
Setup Options
.
2. Press the
Checkmark
key to enter the
View/Edit Current Setup
menu option.
3. Press the
Down Arrow
key to select the
Auxiliary I/O
option.
4. Press the
Checkmark
key to enter the menu.
5. Press the
Down Arrow
key to select
Auxiliary Mode
.
6. Scroll through the available options using the
Checkmark
key until
Remote Alarm
is selected.
7. Press the
Down Arrow
key to select
Alarm On
and enter the menu using the
Checkmark
key.
8. Change the values using the
Down Arrow
and
Checkmark
keys.
9. Press
Cancel
to exit and
Save
any changes.
10. Use the
Down Arrow
key to select the
Warning Hold
and
Alarm Hold
options.
11. Change their values using the
Checkmark
key to scroll through the available settings.
12. Press the
Cancel
key to exit, validate the changes by saving them with the
Checkmark
key.
13. Select
Save to Current File
and then
Overwrite File
, or
Save to New File
and create a new file name
using the touchscreen keypad.
14. Press
Cancel
to exit and return to the Homescreen.