Minimate Pro4 & Minimate Pro6 Alarm Setup
1. Press the
Setup
key to access the
Main Menu
.
2. Press the
Down Arrow
key to select the
View/Edit Setup File
menu option. Press the
Enter
key to enter this menu.
3. Press the
Down Arrow
key to select the
Auxiliary I/O
option. Press the
Right Arrow
key to enter the menu.
4. Press the
Right Arrow
key to change the
Auxiliary I/O
selection to
Remote Alarm
, as shown below:
(the bold text in brackets “
[...]
” represents the available options)
5. Determine how long you want the
Warning Hold Time
and
Alarm Hold Time
to sound. Enter a value using
the
Right Arrow
key to access their editing fields. Press the
Up
/
Down Arrow
keys to change their values. Jump
between the fields by using the
Right
or
Left Arrow
keys. Press the
Enter
key to
Save
the edits of each selection.
Note: The
Warning Hold Time
and
Alarm Hold Time
have a 300 second time limit (5 minutes). When set to 0,
the alarms remain indefinitely and must be reset manually. The
Remote Alarm Controller
is only active once
the
Start Monitor
key is pressed on the unit.
6. Select the
Alarm On
option and press the
Right Arrow
key to scroll through which sensors will trigger an alarm.
Each key press will provide a new setting option.
7. Select the
Vibration Level
option and press the
Right Arrow
key to edit the values.
Note: The Minimate Pro6 monitoring unit using two geophones will offer two options to set the Vibration Alarm
Level, one for each geophone attached.
8. Press the
Right Arrow
key to move the cursor within the value field, and the
Up/Down Arrow
key to
change the value.
9. Press the
Enter
key to
Accept
the new setting, or the
Cancel
key to exit the menu without saving the changes.
10. Select the
Pressure Level
option and press the
Right Arrow
key to edit the values.
Note: The Minimate Pro6 monitoring unit with a geophone and a microphone attached will provide options
to edit the levels for both sensors.
11. Press the
Right Arrow
key to move the cursor within the value field, and the
Up/Down Arrow
key to
change the value.
12. Press the
Enter
key to
Accept
the new setting, or the
Cancel
key to exit the menu without saving the changes.
13. Within the
Edit Current Setup
menu, press the
Enter
key to
Save
the new
Auxiliary I/O
settings, or press the
Cancel
key to
Exit
the menu without saving the changes.
Alarm Indicators
Warning – yellow LED with a
pulsed
sound from the internal warning device.
Alarm – red LED with a
constant
sound from the internal warning device.
External Devices – external alarm devices are optional.