The Remote Alarm Controller is used to indicate when 

the monitoring unit has exceeded its preset trigger levels 

for a Warning signal and Alarm signal. The trigger level 

settings can be configured based on the specific sensors 

connected to the units. The secondary Alarm trigger 

levels must be set higher than the Warning trigger levels.
The remote alarm outputs are isolated from the 

seismograph using normal open relay contacts capable 

of switching loads up to 2 amps and 24 volts DC. 
The connections from the remote alarm output terminals 

to the alarm device(s) can be extended over long 

distances provided there is enough voltage available for 

the alarm device.

Example: 

Pile driving operations often monitor 

ground vibrations. The remote alarm can trigger 

Warning

 signal to notify an operator that the 

activity has exceeded the preset trigger level and 

appropriate action may be required.  If the secondary 

Alarm

 triggers, (when activity exceeds the dedicated 

Vibration Alarm Trigger Level) the operator is notified 

that operations should cease immediately

.

 

Remote Alarm Controller

Tools and Materials Required

Micromate

  • Micromate ISEE Base Unit . . . . . . . . . . . . . . . . . . . . . .(P/N: 721A2501) or

  • Micromate DIN Base Unit . . . . . . . . . . . . . . . . . . . . . .(P/N: 721A2601) or

  • Micromate Swedish Blasting Base Unit . . . . . . . . . . .(P/N: 721A3601) or

  • Micromate Swedish Pile Driving Base Unit . . . . . . . .(P/N: 721A3801)

  • Remote Alarm Controller . . . . . . . . . . . . . . . . . . . . . .(P/N: 721A0901)

  • 10 m (33 ft) Extension Cable . . . . . . . . . . . . . . . .(P/N: 721A0803)

  • 30 m (100 ft) Extension Cable . . . . . . . . . . . . . . .(P/N: 721A0801)

  • 75 m (250 ft) Extension Cable . . . . . . . . . . . . . . .(P/N: 721A0802)

  • Micromate Custom Extension Cable Kit .   .   .   .   .   . . (P/N: 721A3201)
  • External Alarm with Power Source (required, not supplied)

Minimate Pro

  • Minimate Pro4 monitoring unit . . . . . . . . . . . . . . (P/N: 720A2301) or

  • Minimate Pro6 monitoring unit . . . . . . . . . . . . . . (P/N: 720A2401)

  • Remote Alarm Controller . . . . . . . . . . . . . . . . . . . . . . (P/N: 720A3901)

  • 30 m (100 ft) Extension Cable . . . . . . . . . . . . . . .(P/N: 720A3301)

  • 75 m (250 ft) Extension Cable . . . . . . . . . . . . . . .(P/N: 720A3302)

  • Custom Length Extension Cable  .   .   .   .   .   .   .   .   .   .   . (P/N: 301-000034-000)

  • Custom Cable Connector Assembly  .   .   .   .   .   .   .   .  . (P/N: 720A3305)

  • Remote Alarm/Rs-232 Splitter Cable . . . . . . . . . .(P/N: 720A4001)  

     (Used when both a Remote Alarm Controler and a modem must be connected to the monitoring unit at the same time.)

  • External Alarm with Power Source (required, not supplied)

Remote Alarm Controller for Micromate Monitoring Units

Remote Alarm Controller for Minimate Pro4/Pro6 Monitoring Units