OPERATION
First use (once water and electrical connections have been made);
-
Switch the power and water supply on. Screen will light up Red and will run through an initial self-
diagnostic check before starting to fill with water (screen
reads; “NOT READY FILLING”).
-
Once primed with water, the boiler will begin to heat (screen reads; “NOT READY HEATING”).
-
When the correct temperature is achieved, the display will change from Red to White and will read
“READY”
, displaying the water temperature in degrees C.
A warning message (CAUTION HOT WATER) will also be displayed and push button will illuminate Red.
-
The boiler will then continue in a heat/fill cycle until the tank is at full capacity. (During the heat/fill
cycle, small amounts of water are added to ensure the water is always at the correct temperature).
IMPORTANT NOTE: In normal daily use, the boiler may be used as soon as the READY indicator comes on, but
on first install, wait 15 minutes before starting to use.
-
The boiler is now ready for use.
-
Hold cup/teapot under water outlet and press & hold the Red illuminated button to dispense hot
water.
“
CAUTION
BOILING WATER” message will flash reminding the user to
exercise caution.
NOTE: The boiler will dispense “on
-
demand” which is the default setting
(e.g. push & hold button to
dispense water
–
release button to stop dispensing). See below for optional
“TIMED”
dispense:
OPTIONAL “TIMED”
DISPENSE:
This function is appropriate when the cup/teapot being filled is always the same size/capacity.
To change boiler from
“on
-
demand” default setting to “Timed”
dispense:
1)
Switch off on front of unit
2)
Isolate from mains power supply and wait 10 seconds.
3)
Switch boiler back on and at the same time, press & hold the dispense button for 5 seconds.
Boiler will either start to fill with water or the dispense button will begin to flash (depending on
water level in tank).
4)
Hold vessel under dispense outlet
5)
Press & hold the dispense button to fill vessel to the required level. Release button to stop dispense
(NOTE: This can be repeated as many times as necessary, to get the level correct).
6)
Once level in vessel is correct, press the ON/OFF button (below display) to save the measured
dispense amount (this saves the setting and puts the boiler into standby mode).
7)
To continue, switch boiler back on by pressing the ON/OFF button again.
8)
The boiler will now dispense the measured amount into the cup/teapot, each time the button is
pressed.
Top-up feature:
•
At the end of the timed dispense cycle,
the “CAUTION” message will continue to flash
for a further 5
seconds. During this 5-second window, the water level in the cup or teapot can be topped-up by
simply pressing & holding the dispense button.
NOTE
: Once the “CAUTION” message stops flashing, the top
-up facility ends and the boiler reverts
back to timed dispense mode.
To change back from “Timed” to standard “on
-
demand”
dispense:
•
Follow steps 1 to 4 (as above)
then; …
•
Press dispense button very briefly (for less than 1½ seconds)
, to activate the “on
-
demand” function
again.
•
Press ON/OFF button (below display) to save the new setting (boiler will go into standby mode).
•
To continue, switch boiler back on again by pressing the ON/OFF button. The boiler will now
dispense for as long as the button is pressed.