OPERATION 

First use (once water and electrical connections have been made);  

Switch the power and water supply on. Screen will light up Red and will run through an initial self-
diagnostic check before starting to fill with water (screen 

reads; “NOT READY FILLING”).

 

Once primed with water, the boiler will begin to heat (screen reads; “NOT READY HEATING”).

 

When the correct temperature is achieved, the display will change from Red to White and will read 

“READY”

, displaying the water temperature in degrees C.  

A warning message (CAUTION HOT WATER) will also be displayed and push button will illuminate Red.  

The boiler will then continue in a heat/fill cycle until the tank is at full capacity. (During the heat/fill 
cycle, small amounts of water are added to ensure the water is always at the correct temperature).  
 

IMPORTANT NOTE: In normal daily use, the boiler may be used as soon as the READY indicator comes on, but 
on first install, wait 15 minutes before starting to use.  

The boiler is now ready for use.      

Hold  cup/teapot  under  water  outlet  and  press  &  hold  the  Red  illuminated  button  to  dispense  hot 
water. 

CAUTION 

BOILING WATER” message will flash reminding the user to 

exercise caution.   

NOTE: The boiler will dispense “on

-

demand” which is the default setting 

(e.g. push & hold button to 

dispense water 

 release button to stop dispensing). See below for optional 

“TIMED”

 dispense:   

 

OPTIONAL “TIMED”

 DISPENSE: 

 

This function is appropriate when the cup/teapot being filled is always the same size/capacity. 

 

To change boiler from 

“on

-

demand” default setting to “Timed”

 dispense:  

 

1)

 

Switch off on front of unit 

2)

 

Isolate from mains power supply and wait 10 seconds. 

3)

 

Switch boiler back on and at the same time, press & hold the dispense button for 5 seconds.  
Boiler will either start to fill with water or the dispense button will begin to flash (depending on 
water level in tank). 

4)

 

Hold vessel under dispense outlet 

5)

 

Press & hold the dispense button to fill vessel to the required level. Release button to stop dispense 
(NOTE: This can be repeated as many times as necessary, to get the level correct).    

6)

 

Once level in vessel is correct, press the ON/OFF button (below display) to save the measured 
dispense amount (this saves the setting and puts the boiler into standby mode).  

7)

 

To continue, switch boiler back on by pressing the ON/OFF button again. 

8)

 

The boiler will now dispense the measured amount into the cup/teapot, each time the button is 
pressed. 
 

Top-up feature:       

 

 

 

At the end of the timed dispense cycle, 

the “CAUTION” message will continue to flash 

for a further 5 

seconds. During this 5-second window, the water level in the cup or teapot can be topped-up by 
simply pressing & holding the dispense button.  
NOTE

: Once the “CAUTION” message stops flashing, the top

-up facility ends and the boiler reverts 

back to timed dispense mode.        

      

To change back from “Timed” to standard “on

-

demand”

 dispense: 

 

 

Follow steps 1 to 4 (as above) 

then; …

 

 

Press dispense button very briefly (for less than 1½ seconds)

, to activate the “on

-

demand” function 

again. 

 

Press ON/OFF button (below display) to save the new setting (boiler will go into standby mode). 

 

To continue, switch boiler back on again by pressing the ON/OFF button. The boiler will now 
dispense for as long as the button is pressed.    

Содержание SureFlow Touch WMS6PB

Страница 1: ...el WMS6PB DB600 W Auto Fill Wall Mount Catering Boiler with Push Button Dispense INSTALLATION AND USER INSTRUCTIONS INSTANTA LIMITED Canning Road Southport Merseyside PR9 7SN Tel 01704 501114 Fax 01704 501115 IB91 ISS 03 ...

Страница 2: ...RACKET SPILL TRAY KIT 6 OPTIONAL FILTER MONITOR 5 CLEANING 7 SERVICE WARNINGS FAULT DIAGNOSTICS 7 MAINTENANCE SPARES SERVICE INFORMATION 8 GUARANTEE 8 INTRODUCTION Dear Customer Thank you for purchasing this Instanta product Your new water boiler is designed to give you years of trouble free service provided that the instructions contained in this manual are followed All new series Instanta produc...

Страница 3: ...iance by a person responsible for their safety Children should be supervised to ensure they do not play with the appliance Always disconnect the unit from the power supply before servicing The unit must be earthed Keep these instructions in a safe place near the unit for future reference ENVIRONMENTAL Information on Disposal for Users of Waste Electrical Electronic Equipment The crossed out wheeli...

Страница 4: ...vided Once the machine is positioned tighten the top screws and insert the bottom screw Do not block ventilation holes in boiler case b ELECTRICAL CONNECTION The circuit should be protected by its own 13amp double pole connection unit with flex outlet to BS5733 alternatively the circuit should have a means of disconnection incorporated in fixed wiring having a contact separation of at least 3mm in...

Страница 5: ...lbow facing the wall Push the 15mm cold water supply firmly into the elbow NOTE Water that has been treated by the Reverse Osmosis process can become aggressive due to lack of minerals or Ions and in extreme cases can cause leaching and corrosion of pipes fittings and other metal parts within the appliance If the appliance is being fed by water treated by Reverse Osmosis we strongly recommend that...

Страница 6: ...outlet VENT PIPE A small silicone rubber tube connects the tank lid to the back panel Ensure this is connected and hasn t come off in transit and that the outlet fitting in the back panel is not obstructed e FITTING CASE Attach the Earth wire connection to bottom of stainless steel boiler case using M4 screw washer supplied Offer up the case to the wall mounted boiler and plug in the two communica...

Страница 7: ...mand default setting to Timed dispense 1 Switch off on front of unit 2 Isolate from mains power supply and wait 10 seconds 3 Switch boiler back on and at the same time press hold the dispense button for 5 seconds Boiler will either start to fill with water or the dispense button will begin to flash depending on water level in tank 4 Hold vessel under dispense outlet 5 Press hold the dispense butto...

Страница 8: ... PR in centre of screen then release button Temperature setting is displayed Press hold button long push for approximately 5 seconds until screen changes to show empty filter symbol default filter setting Press button short push to scroll between the different filter settings SOFT 13001 litres MEDIUM 9001 litres HARD 6001 litres EMPTY FILTER SYMBOL No Filter counter With the required filter settin...

Страница 9: ...us fault conditions Some of these are less serious and the machine will continue to operate as normal while others are more serious and will disable the unit Before calling for service isolate the machine at the mains supply and then switch back on after 10 minutes If the fault does not clear call technical support for advice SCREEN MESSAGE POSSIBLE CAUSES ACTION R E A D Y CHECK WATER WHITE SCREEN...

Страница 10: ...GUARANTEE Your boiler is guaranteed for two years from date of installation Our guarantee includes on site labour and parts for problems caused by fault of manufacture and component failure with the following exclusions 1 Problems caused by hard water and lime scale We regret that we cannot be held responsible for problems caused by hard water 2 Accidental damage misuse or use not in accordance wi...

Отзывы: