TECHNICAL SPECIFICATION 

 

Model:  

WMS6PB (DB600-W) 

Width: 

340 mm 

Height: 

478 mm 

Depth: 

260 mm 

Power Rating: 

3.0 kW 

Weight-Empty: 

9.8 KG 

Weight-Full: 

18.5 KG 

Water Inlet Pressure: 

2 to 7 Bar 

 
 

INSTALLATION 

 

 

a) POSITIONING THE UNIT 

 
The heater should be positioned in a convenient place, on a wall that is capable of supporting it safely (refer 
to Technical Specification above for weight of boiler). Use the mounting template and fitting kit provided. 

Locate in an area where there is adequate space to use the boiler safely (e.g. free from risk of congestion 
and tripping hazards).    
 
Position the boiler so that the tap is approximately 400mm above a draining board. Leave sufficient space 
around the unit to enable access for servicing, paying particular attention to the position of the top-centre 
fixing screw that holds the case in place. 

When mounting 

on wall…screw in the top two screws leaving about 6mm protruding and hang the machine 

using the keyhole slots provided. Once the machine is positioned, tighten the top screws and insert the bottom 
screw. 

Do not block ventilation holes in boiler case  

 

 

b) ELECTRICAL CONNECTION 

 
The circuit should be protected by its own 13amp double-pole connection unit with flex outlet to BS5733, 
alternatively the circuit should have a means of disconnection incorporated in fixed wiring, having a contact 
separation of at least 3mm in all poles. Minimum cable size is 1.5mm

2

. The use of an ELCB is recommended.  

 

WARNING: This appliance must be earthed. 

Electrical installation should conform to current I.E.E. wiring regulations. 

When using fixed wiring, the bare section of earth must be sleeved to within 8mm of the end. 

Only a qualified electrician should carry out this work. 

 

BASE ENTRY OF CABLE:

 Use the cable gland. Loosen cable-gripping nut and pass cable through gland, leaving 

enough free cable to connect to terminal block. Tighten cable gland grip nut.         

 
Alternative Rear Entry Installation (Electrical)

: The fixed or flexible cable is connected direct to the terminal block 

 the cable gland is 

not utilised. 

 
DO NOT SWITCH ON UNTIL THE INSTALLATION IS COMPLETE AND THE CASE IS IN PLACE  

 

 

 

 
 

Содержание SureFlow Touch WMS6PB

Страница 1: ...el WMS6PB DB600 W Auto Fill Wall Mount Catering Boiler with Push Button Dispense INSTALLATION AND USER INSTRUCTIONS INSTANTA LIMITED Canning Road Southport Merseyside PR9 7SN Tel 01704 501114 Fax 01704 501115 IB91 ISS 03 ...

Страница 2: ...RACKET SPILL TRAY KIT 6 OPTIONAL FILTER MONITOR 5 CLEANING 7 SERVICE WARNINGS FAULT DIAGNOSTICS 7 MAINTENANCE SPARES SERVICE INFORMATION 8 GUARANTEE 8 INTRODUCTION Dear Customer Thank you for purchasing this Instanta product Your new water boiler is designed to give you years of trouble free service provided that the instructions contained in this manual are followed All new series Instanta produc...

Страница 3: ...iance by a person responsible for their safety Children should be supervised to ensure they do not play with the appliance Always disconnect the unit from the power supply before servicing The unit must be earthed Keep these instructions in a safe place near the unit for future reference ENVIRONMENTAL Information on Disposal for Users of Waste Electrical Electronic Equipment The crossed out wheeli...

Страница 4: ...vided Once the machine is positioned tighten the top screws and insert the bottom screw Do not block ventilation holes in boiler case b ELECTRICAL CONNECTION The circuit should be protected by its own 13amp double pole connection unit with flex outlet to BS5733 alternatively the circuit should have a means of disconnection incorporated in fixed wiring having a contact separation of at least 3mm in...

Страница 5: ...lbow facing the wall Push the 15mm cold water supply firmly into the elbow NOTE Water that has been treated by the Reverse Osmosis process can become aggressive due to lack of minerals or Ions and in extreme cases can cause leaching and corrosion of pipes fittings and other metal parts within the appliance If the appliance is being fed by water treated by Reverse Osmosis we strongly recommend that...

Страница 6: ...outlet VENT PIPE A small silicone rubber tube connects the tank lid to the back panel Ensure this is connected and hasn t come off in transit and that the outlet fitting in the back panel is not obstructed e FITTING CASE Attach the Earth wire connection to bottom of stainless steel boiler case using M4 screw washer supplied Offer up the case to the wall mounted boiler and plug in the two communica...

Страница 7: ...mand default setting to Timed dispense 1 Switch off on front of unit 2 Isolate from mains power supply and wait 10 seconds 3 Switch boiler back on and at the same time press hold the dispense button for 5 seconds Boiler will either start to fill with water or the dispense button will begin to flash depending on water level in tank 4 Hold vessel under dispense outlet 5 Press hold the dispense butto...

Страница 8: ... PR in centre of screen then release button Temperature setting is displayed Press hold button long push for approximately 5 seconds until screen changes to show empty filter symbol default filter setting Press button short push to scroll between the different filter settings SOFT 13001 litres MEDIUM 9001 litres HARD 6001 litres EMPTY FILTER SYMBOL No Filter counter With the required filter settin...

Страница 9: ...us fault conditions Some of these are less serious and the machine will continue to operate as normal while others are more serious and will disable the unit Before calling for service isolate the machine at the mains supply and then switch back on after 10 minutes If the fault does not clear call technical support for advice SCREEN MESSAGE POSSIBLE CAUSES ACTION R E A D Y CHECK WATER WHITE SCREEN...

Страница 10: ...GUARANTEE Your boiler is guaranteed for two years from date of installation Our guarantee includes on site labour and parts for problems caused by fault of manufacture and component failure with the following exclusions 1 Problems caused by hard water and lime scale We regret that we cannot be held responsible for problems caused by hard water 2 Accidental damage misuse or use not in accordance wi...

Отзывы: