Installation [All Models]

a) POSITIONING THE UNIT

The heater should be positioned in a convenient 
place, on a wall that is capable of supporting it 
safely (refer to table above for weight of boiler). 
Use the mounting template and fitting kit provided.

Position the boiler so that the tap is approximately 
400mm above a draining board. Leave sufficient 
space around the unit to enable access for servicing, 
paying particular attention to the position of the  
top-centre fixing screw that holds the case in place.

When mounting on wall…screw in the top two 
screws leaving about 6mm protruding and hang the 
machine using the keyhole slots provided. Once the 
machine is positioned, tighten the top screws and 
insert the bottom screw.

b) ELECTRICAL CONNECTION 

The circuit should be protected by its own 13amp 
double-pole connection unit with flex outlet to 
BS5733, alternatively the circuit should have a means 
of disconnection incorporated in fixed wiring, having a 
contact separation of at least 3mm in all poles. 
Minimum cable size is 1.5mm

2

. The use of an 

ELCB is recommended. 

•  WARNING: This appliance must be earthed.

•  Electrical installation should conform to current  
 

I.E.E. wiring regulations.

•  When using fixed wiring, the bare section of earth  
 

must be sleeved to within 8mm of the end.

•  Only a qualified electrician should carry out  
 

this work.

BASE ENTRY OF CABLE:

 Use the cable gland. 

Loosen cable-gripping nut and pass cable through 
gland, leaving enough free cable to connect to 
terminal block. Tighten cable gland grip nut.    

   

Alternative Rear Entry Installation (Electrical):

 

The fixed or flexible cable is connected direct to the 
terminal block – the cable gland is not utilised.

DO NOT SWITCH ON UNTIL THE INSTALLATION IS 
COMPLETE AND THE CASE AND TAP ARE IN PLACE

 

 

c) WATER CONNECTION

NOTE: Although it will not harm the boiler, it should 
not be operated with the water supply turned off.  

The water supply must have a pressure not 
exceeding 7 bar and no lower than 2 bar.  

If the mains water pressure is below 2 bar  
a fault situation could arise.

  

Model

WMS2 (WA2N)

WMS5 (WA5N)

WMS10 (WA10N)

Width

mm

254

290

340

Depth

mm

187

205

247

Height

mm

428

432

480

Voltage & Supply

V

230, AC (50Hz)

230, AC (50Hz)

230, AC (50Hz)

Power Rating

kW

2.0 single-phase

3.0 single-phase

3.0 single-phase

Fill Type

Automatic

Automatic

Automatic

Rapid Draw Off

Litres

2.5

5

10

Weight (empty)

KG

6.5

7.5

9.7

Weight (full)

KG

10.5

14.7

22.7

Water Inlet 

Pressure

Bar

2 to 7

2 to 7 bar

2 to 7 bar

Technical Information

Outer casing and tank are constructed in type-304 and type-316 grade stainless steel.  
The tank is fully insulated with high-temperature polystyrene. 

The appliance has electronic control of the main functions. This means that the heating,  
filling and temperature are controlled precisely within given parameters.

4

5

Содержание SureFlow Series

Страница 1: ...The Professional s Choice SureFlow Wall Mount Series WMS2 WMS5 WMS10 WA2N WA5N WA10N Auto Fill Wall mount Catering Water Boilers Installation And User Instructions...

Страница 2: ...SUPPORT GUARANTEE 7 SERVICE WARNINGS FAULT DIAGNOSTICS 7 8 Introduction Dear Customer Congratulations on the purchase of your Instanta machine Your new water boiler is designed to give you years of tr...

Страница 3: ...d Always disconnect the unit from the power supply before servicing Keep these instructions in a safe place for future reference Environmental Information Information on Disposal for Users of Waste El...

Страница 4: ...lified electrician should carry out this work BASE ENTRY OF CABLE Use the cable gland Loosen cable gripping nut and pass cable through gland leaving enough free cable to connect to terminal block Tigh...

Страница 5: ...can cause problems Fitting a scale reducer will help minimise scale but will not eliminate scale completely WE REGRET THAT INSTANTA CANNOT BE HELD RESPONSIBLE FOR SCALE RELATED PROBLEMS IF A SCALE RE...

Страница 6: ...to use 2 Dispense water using the lever tap on the front of the appliance Safety Caution Use with caution as the boiler dispenses near boiling water Cleaning The external surfaces of the machine can b...

Страница 7: ...iagnostics The boiler is fitted with an intelligent fault diagnosing system and can detect certain fault conditions as follows FILLING Flashing The white FILLING lamp flashes to indicate water starvat...

Страница 8: ...ed or green or red and green If the problem reoccurs contact the Instanta Service Department 01704 502911 Dripping Taps These components are subject to wear tear but in the event of a tap failing with...

Отзывы: