7
SERVICE WARNINGS AND FAULT DIAGNOSIS
Your boiler is fitted with an intelligent fault diagnosing system and is able to detect various fault
conditions. Some of these are less serious and the machine will continue to operate as normal, while
others are more serious and will disable the unit.
Before calling for service, switch the machine off at the mains supply. Draw-off a small amount of water
and then switch back on after 10 minutes. If the fault does not clear, call technical support for advice.
SCREEN MESSAGE
POSSIBLE CAUSES:
ACTION;
R E A D Y
! CHECK WATER!
WHITE SCREEN
•
Water turned off
•
Inlet hose kinked or bent
•
Low
in-coming
water
pressure
•
Check water supply and
stop-cock
•
Check in-coming water
is at minimum of 2-bar
R E A D Y
! CLEAN PROBES !
WHITE SCREEN
•
Low-water
level
probe
scaled up
•
De-scale inside of tank
and level sensors
N O T R E A D Y
HEATING
RED SCREEN - FLASHING
•
Over-boil
safety
switch
tripped on initial heat-up.
•
Faulty Element
•
Boil-dry
safety
switch
tripped or faulty
•
Isolate machine and
wait 10mins, then turn
back on again.
•
Call service if fault
persists.
N O T R E A D Y
HEATING - icon also flashing
RED SCREEN - FLASHING
•
Over-boiled when in READY
mode (due to excessive
lime-scale in tank).
•
Thermistor disconnected or
wires cut.
•
De-scale tank and level-
sensors
•
Reduce
temperature
setting
•
Call service if fault
persists
N O T R E A D Y
‘OF’ displayed
RED SCREEN
•
Unit has overfilled to top
level sensor
•
De-scale tank and level-
sensors
N O T R E A D Y
‘TH’ displayed
RED SCREEN
•
Thermistor has failed
•
Replace thermistor
R E A D Y *
CHANGE FILTER
•
Filter cartridge is exhausted
and should be replaced as
soon as convenient.
•
Replace filter cartridge
* Optional