4
TECHNICAL SPECIFICATION
Model
CTS13SL
(SL13)
Width
mm
180
Depth
mm
520
Height
mm
738
Power Rating
KW
3.0
Weight (Empty)
KG
13.4
Weight (Full)
KG
28.8
Water Inlet Pressure:
Bar
2 to 7
INSTALLATION
The boiler must be installed on a horizontal work surface with sufficient strength to support its weight.
Locate in an area where there is adequate space to use the boiler safely (e.g. free from risk of
congestion and tripping hazards).
Connection to Mains Water Supply:
Connect the WRAS approved water filling hose (3/4”BSP) to the inlet connection point on the back of
the boiler and the other end to the mains water supply, via an accessible isolating tap with a ¾”BSP
thread.
IMPORTANT: If micro-bore pipe is used instead of the inlet hose supplied, the size must be minimum OD
3/8”(10mm)
.
The water supply must have a pressure not exceeding 7bar (96psi), and no lower than 1.5bar (20psi)
NOTE: If your water pressure exceeds 7bar, fit a suitable pressure reduction valve.
We regret that Instanta cannot be held responsible for any machine malfunctions if the water pressure exceeds that stated. If in
doubt, consult your water supply company
Electrical Connection:
The boiler must be Earthed.
The product can be connected to a standard domestic 13amp outlet.
Overflow:
The drip-tray has a limited capacity and is designed to handle small spillages and drips. Wherever
possible, we strongly recommend that it is connected to a permanent waste outlet using the fitting kit
provided.
If preferred, and as an alternative, the overflow can be connected from the back of the machine using
an optional rear-overflow kit (Pt. No: ROFK1) available from Instanta Spares Department (01704
502905).
IMPORTANT: Whichever overflow connection is chosen, the diameter of the pipe used must be no less
than 15mm.
NOTE:
Where it is absolutely not possible to direct the boiler overflow outlet to a permanent waste as
described above, then for peace of mind, we strongly advise that the boiler be switched off and the
mains water supply isolated overnight.