Instanta SureFlow Compact Series Скачать руководство пользователя страница 7

SAFETY CONTROLS:

The majority of possible faults have been covered 
above. However, in certain circumstances, one of two 
different safety controls within the boiler may have 
activated;

1). Over-boil Safety cut-out

 

Activates if boiler produces excess steam. 
This can be due to; 

 

• lime-scale within the tank,

 

• a temporary interruption in the water supply.

 

•  a faulty temperature sensor or internal 

component (triac). 

TO RESET BOILER; 

Switch off at the mains power 

supply and allow the boiler to cool down for ten 
minutes before switching back on (the safety device 
should automatically reset).

EARLIER MODELS: 

The over-boil cut-out will require 

a manual reset. Contact Instanta Technical Support 
department for assistance with this.  

2). Boil-dry Safety cut-out.

This operates if the boiler has been boiled dry, 
for example, due to lime scale build-up or water 
starvation. 

The boil-dry safety switch will require resetting. 
Please contact our Technical Support department for 
assistance with this.

Safety Caution: Isolate boiler from power supply before 
removing any outer panels or attempting any reset.

In any of these events the indicator lamp will flash red 
or green or red and green. If the problem reoccurs 
contact the Instanta Service Department  
– 01704 502911

Service/Technical Support:

Tel: 01704 502911

To ensure your service enquiry is handled as efficiently 
as possible, please have the following information 
available;

•  Brief description of problem

•  Product Type (model)

•   Serial Number (label on right-hand side of 

machine). This is essential

Guarantee

Your boiler is guaranteed for twelve months from date 
of installation.

Our guarantee includes on site labour and parts 
for problems caused by fault of manufacture and 
component failure with the following exclusions:

1   Problems caused by hard water and lime scale. 

We regret that we cannot be held responsible for 
problems caused by hard water

2   Dripping Taps. These components are subject 

to wear and tear but in the event of a tap failing 
within twelve months of installation, we will be 
pleased to replace the tap assembly by post. 
Fitting is very simple and requires no tools. An 
engineer call out is not necessary. 

3   Accidental damage, misuse or use not in 

accordance with these instructions and damage 
caused by incorrect installation.  

The manufacturer disclaims any liability for incidental, 
or consequential damages.

6

7

Содержание SureFlow Compact Series

Страница 1: ...The Professional s Choice SureFlow compact range CTS3 CTS5 CTS10 1000 M 1000 C 1500pou Auto Fill Catering Water Boiler Installation And User Instructions ...

Страница 2: ... FAULT DIAGNOSTICS 6 7 TECHNICAL SUPPORT 7 GUARANTEE 7 Introduction Dear Customer Congratulations on the purchase of your Instanta machine Your new water boiler is designed to give you years of trouble free service provided that the instructions contained in this manual are followed All new series Instanta products are energy efficient simple to operate and easy to service Find out more about Inst...

Страница 3: ... supervised to ensure they do not play with the appliance Always disconnect the unit from the power supply and allow it to cool down before servicing The components in the draw off tap are subject to wear tear Check periodically at least every 12 months as part of a general maintenance routine We recommend that a spare tap spring tap washer or upper tap assembly are held in case of emergencies and...

Страница 4: ...ggressive due to lack of minerals or Ions and in extreme cases can cause leaching and corrosion of pipes fittings and other metal parts within the appliance If the appliance is being fed by water treated by Reverse Osmosis we recommend that the water is tested regularly If you have any queries in respect please contact our customer services team We regret that Instanta cannot be held responsible f...

Страница 5: ...g When the boiler reaches the correct temperature the GREEN LIGHT will show that the boiler is ready IMPORTANT NOTE In normal daily use the boiler may be used as soon as the GREEN LIGHT shows but on first install wait 15 minutes before starting to use Regular Daily Use Switch boiler on Wait for the GREEN LIGHT The water will then be at the correct temperature Dispense water via the lever tap CAUTI...

Страница 6: ...eck in coming water is at minimum of 2 bar Flashing Red Safety Control has activated An internal component has failed See Safety Controls below Contact Instanta Technical Sup port Flashing Red Green Over boil safety switch tripped on initial heat up Faulty Element Boil dry safety control activated Re set required Isolate power to appliance Push in manual reset button remove back panel to access Ca...

Страница 7: ...set In any of these events the indicator lamp will flash red or green or red and green If the problem reoccurs contact the Instanta Service Department 01704 502911 Service Technical Support Tel 01704 502911 To ensure your service enquiry is handled as efficiently as possible please have the following information available Brief description of problem Product Type model Serial Number label on right...

Страница 8: ...INSTANTA LIMITED Canning Road Southport Merseyside PR9 7SN Tel 01704 501114 Fax 01704 501115 IB27 ISS 04 FM 36413 EMS 75807 ...

Отзывы: