Instanta SureFlow Compact Series Скачать руководство пользователя страница 6

•   Wipe clean the level sensing probes.

•   Flush with copious amounts of cold water to 

ensure all traces of de-scaler are removed before 
using the boiler again.  

•   Replace evaporation plates, tank-lid and outer 

lid. 

DRAW-OFF TAP:

The tap spring and washer components are subject 
to ware & tear. It is advisable to keep a spare tap-
spring and washer in case of emergencies.  

ACCESSORIES & SPARES (TEL: 01704 502905)

Replacement Tap Washer: 

TP1001/L

Replacement Tap Spring: 

TP1007/N

Multi-Filter Cartridge: 

AQ35 

Head for Multi-Filter: 

AQ35H

Rear-overflow Kit 

ROFK-1 

(connection to perm waste):

A full range of spares and accessories are available 
from our spares department.

Light Indication

Possible Causes

Action

Flashing Green:

•  The bottom probe is scaled up.

•  De-scale inside of tank and level 

sensors 

Flashing Orange:

•  Water turned off
•  Inlet hose kinked or bent
•  Low in-coming water pressure

•  Check water supply and stop-

cock

•  Check in-coming water is at 

minimum of 2-bar   

Flashing Red:

•  Safety Control has activated 
•  An internal component has failed.

•  See  Safety Controls below
•  Contact Instanta Technical Sup-

port.

Flashing Red & 

Green:

•  Over-boil safety switch tripped 

on initial heat-up.

•  Faulty Element
•  Boil-dry safety control activated

•  Re-set required: Isolate power to 

appliance. Push-in manual reset 
button (remove back panel to 
access).  

•  Call service if fault persists.  

Rapid Flashing Red:   •  The probes are scaled up and 

water has risen to a dangerous 
level (heating and filling functions 
are disabled).

•  De-scale inside of tank and level 

sensors. 

Service Warnings And Fault Diagnosis

Your boiler is fitted with an intelligent fault diagnosing 
system and is able to detect various fault conditions. 
Some of these are less serious and the machine will 
continue to operate as normal, while others are more 
serious and will disable the unit.

Before calling for service, switch the machine off at 
the mains supply. Draw-off a small amount of water 
and then switch back on after 10 minutes. If the fault 
does not clear, call technical support for advice.    

6

Содержание SureFlow Compact Series

Страница 1: ...The Professional s Choice SureFlow compact range CTS3 CTS5 CTS10 1000 M 1000 C 1500pou Auto Fill Catering Water Boiler Installation And User Instructions ...

Страница 2: ... FAULT DIAGNOSTICS 6 7 TECHNICAL SUPPORT 7 GUARANTEE 7 Introduction Dear Customer Congratulations on the purchase of your Instanta machine Your new water boiler is designed to give you years of trouble free service provided that the instructions contained in this manual are followed All new series Instanta products are energy efficient simple to operate and easy to service Find out more about Inst...

Страница 3: ... supervised to ensure they do not play with the appliance Always disconnect the unit from the power supply and allow it to cool down before servicing The components in the draw off tap are subject to wear tear Check periodically at least every 12 months as part of a general maintenance routine We recommend that a spare tap spring tap washer or upper tap assembly are held in case of emergencies and...

Страница 4: ...ggressive due to lack of minerals or Ions and in extreme cases can cause leaching and corrosion of pipes fittings and other metal parts within the appliance If the appliance is being fed by water treated by Reverse Osmosis we recommend that the water is tested regularly If you have any queries in respect please contact our customer services team We regret that Instanta cannot be held responsible f...

Страница 5: ...g When the boiler reaches the correct temperature the GREEN LIGHT will show that the boiler is ready IMPORTANT NOTE In normal daily use the boiler may be used as soon as the GREEN LIGHT shows but on first install wait 15 minutes before starting to use Regular Daily Use Switch boiler on Wait for the GREEN LIGHT The water will then be at the correct temperature Dispense water via the lever tap CAUTI...

Страница 6: ...eck in coming water is at minimum of 2 bar Flashing Red Safety Control has activated An internal component has failed See Safety Controls below Contact Instanta Technical Sup port Flashing Red Green Over boil safety switch tripped on initial heat up Faulty Element Boil dry safety control activated Re set required Isolate power to appliance Push in manual reset button remove back panel to access Ca...

Страница 7: ...set In any of these events the indicator lamp will flash red or green or red and green If the problem reoccurs contact the Instanta Service Department 01704 502911 Service Technical Support Tel 01704 502911 To ensure your service enquiry is handled as efficiently as possible please have the following information available Brief description of problem Product Type model Serial Number label on right...

Страница 8: ...INSTANTA LIMITED Canning Road Southport Merseyside PR9 7SN Tel 01704 501114 Fax 01704 501115 IB27 ISS 04 FM 36413 EMS 75807 ...

Отзывы: