16
Installation instructions & user guide
T210042 InstaTap office manual v1.01 June 2022
This device must be installed vertically with
the direction of flow downwards (inlet at
the top , outlet at the bottom. See Fig. 1
• The Water Block should be installed in a convenient
location on the water supply line to the appliance.
• Rotate Pointer ‘P’ (see Fig.3) until in line with the max.
required flow. The number scale corresponds to 5 litres
of flow i.e. 1 = 5 litres, 10 = 50 litres.
• The key (see Fig.2) should be used to adjust the pointer.
• The inlet should be connected via a 15mm copper tail.
• The outlet shall be connected via the 3/4” - 3/8” push fit
brass fitting supplied.
• Ensure that the direction of flow through the Water Block is correct and
that the filter screen (see Fig.2) is inserted correctly with the convex
surface facing towards the water supply.
6.7 Water block
6.7.1 Reset procedure
• The Water Block will activate and shut off the supply if more water than the
set amount is drawn off at one time.
• In this event isolate the water supply to the Water Block.
• Identify and repair the leak then press the reset lever (Fig. 2).
• Tripping issues, contact Technical support on 0345 6 005 005 for advice.
Fig. 1
Fig. 3
Dir
ec
tion of flo
w
0
1
2
3 4
5
6
7
8
9
Fig. 2
Fit key to adjust flow
Reset lever
Seal
Reset
device
Direction of
flow
Filter
screen
0 1
2
3
4
5
6
7
8
9
SECTION 6 Installing the under counter appliances
0 1
2
3
4
5
6
7
8
9
!
!