NOTE: 

Water that has been treated by the Reverse Osmosis process can become aggressive (due 

to lack of minerals or Ions), and in extreme cases can cause leaching and corrosion of pipes, 
fittings and other metal parts within the appliance.

 

If the appliance is being fed by water treated by Reverse Osmosis, we strongly recommend that 
the water is tested regularly.

 

If you have any queries in this respect, please contact our customer services team.

 

 

 

WE REGRET THAT INSTANTA CANNOT BE HELD RESPONSIBLE FOR SCALE RELATED PROBLEMS IF 
A SCALE REDUCER HAS BEEN INSTALLED 
 
MAIN UNIT OVERFLOW 

 

A 15mm push-fit overflow connection point is provided [right-hand side of under-counter unit]. This 
should  be  directed  to  a  permanent  waste 

(see  drawing)

.  Use  pipe-work  with  a  continuous  fall, 

diameter of pipe to be no less than 15mm. [NOTE: An air gap must be provided within 500mm of 
the  connection  point.  Failure  to  provide  an  air  gap  within  this  distance  could  cause  an  air  lock 
which would stop the water discharging in the event of an overflow]. 
 
Failure to connect the overflow-outlet to a permanent waste or drain, could lead to property 
damage from flooding.  
 
If in all circumstances, it is absolutely not possible to direct the boiler overflow-outlet to a 
permanent waste or drain, then the mains water supply to the boiler should be isolated and the 
unit switched off whenever it is left unattended for long periods (e.g. overnight). 
 
IMPORTANT: 

Whilst reasonable precaution is taken to prevent an overflow, Instanta cannot be 

held responsible for any damage caused as a result of incorrect installation or blockage of the 
overflow or failure to direct the overflow to a safe outlet.

 

 
FONT OVERFLOW 
 
Drip tray drain kit 

 The drain kit needs to be installed in the drip tray with the kit supplied. When 

this  is  done,  the  drain  pipe  needs  connecting  to  a  permanent  waste.  This  drain  carries  any 
drips/spillages from the drip tray away.   
 
d) ELECTRICAL CONNECTION  

 

UCB10, UCB15 & UCB40-STA-S [3.0KW MODELS] 

  

Your machine is supplied with a standard 3-pin bonded plug and lead with 13amp fuse. 

 

UCB47 [4.5KW] 

 Standard configuration, suitable for 20amp supply. 

 

Your machine is supplied with a 2mtr long electrical cord [3 x 2.5mm], for connection to a suitable 
20A, single-phase electrical supply, via an isolation switch.   

 

UCB47 [6.75KW] - Optional configuration, suitable for 30amp supply.

  

 

The UCB47 can also be up-rated to 6.75KW, by connecting the link wire [supplied] 

 see separate 

instruction sheet. In this configuration, a suitable 30amp, single-phase supply is required. 

 

 

REMEMBER:  Using  a  permanent  black  marker  pen,  indicate  the  chosen  electrical  configuration 
(KW input rating) on the rating label [right-hand side of under-counter unit].   

 
 
 
 

Содержание InstaTap UCB Series

Страница 1: ...UCB Series Single Font Units InstaTap Under Counter Push Button Dispenser INSTALLATION USER INSTRUCTION MANUAL IB24 S...

Страница 2: ...lpful in notifying users that the appliance contains and dispenses near boiling water During normal use of the boiler all surfaces remain cool However care should be taken to avoid potential injury fr...

Страница 3: ...ze H x W x D 502 x 254 x 440 Voltage 220 240V single phase 50 60Hz Supply AC Rated Input 3 0kW Output Amps 13A Fill Type Automatic Max Rapid Draw Off 10 Litres 50 x 200ml 7oz cups Recovery per Minute...

Страница 4: ...exceeding 7 bar 96psi and no lower than 2 bar 28psi If your water pressure exceeds 7 bar a suitable pressure reduction valve may need to be fitted to the water supply to bring the pressure to a level...

Страница 5: ...anent waste or drain then the mains water supply to the boiler should be isolated and the unit switched off whenever it is left unattended for long periods e g overnight IMPORTANT Whilst reasonable pr...

Страница 6: ...n illuminates RED BUT ON FIRST INSTALLATION YOU SHOULD WAIT AT LEAST 10 MINUTES BEFORE STARTING TO USE THE WATER Your machine will not fill completely at once The water input is electronically control...

Страница 7: ...l technical support for advice SCREEN MESSAGE POSSIBLE CAUSES ACTION R E A D Y CHECK WATER WHITE SCREEN Water turned off Inlet hose kinked or bent Low in coming water pressure Check water supply and s...

Страница 8: ...Any scale which is difficult to remove can be dissolved by using a solution of Renegite de scaler Wipe clean the level sensing probes Ensure all traces of de scaler are removed before replacing tank...

Отзывы: