FILTER COUNTER 

(Optional if a filter or softener has been fitted):

 

 
If an external filter/softener is fitted to the unit there is an optional filter-counter installed in the 
software. This counter measures the water passing through the boiler and reminds the customer (via 
the display screen) to change the filter when required. 

Note: This counter is set to ‘Off’ as standard.

 

 
To enable filter-counter, proceed as follows: 
 

-

 

Turn machine off on front panel.  

-

 

Press & hold “on/off” button (for approximately 12 seconds) until red screen shows “PR” in 

centre of screen, then release button. Temperature setting is displayed.    

-

 

Press & hold button (long push) for approximately 5 seconds until screen changes to show 

“empty filter symbol” (default filter setting).

 

-

 

Press button (short push) to scroll between the different filter settings; 

SOFT (13001 litres) 
MEDIUM (9001 litres) 
HARD (6001 litres) 
EMPTY FILTER SYMBOL (No Filter counter) 

-

 

With  the required filter setting  selected, Press  &  hold button  (long  push)  for  4  seconds  to 
save. 

-

 

Press & hold button (long push) for approximately 6 seconds until display goes blank. 

-

 

Turn machine back on again. 

-

 

TO  RE-SET  &  CONFIRM  NEW  SETTINGS; 

…P

ress  &  hold  button,  screen  will  go  blank  but 

continue to hold, until “READY” message is displayed on a red screen. 

 

-

 

The unit can then be switched back on and used.      
 

If in doubt as to the hardness of water supplied in your area, consult your local water authority 

 
 

PREVENTATIVE MAINTENANCE: 

 

AQ35/KIT 

 The Instanta AQ35 high-flow multi-filter delivers the best quality of water by removing 

sediment and impurities such as chlorine. The filter also reduces scale build-up which results in lower 
running costs, improved energy efficiency and longer life expectancy. Filter capacity: up to 13,500 
litres      
 

Available from Instanta Spares Department: 01704 501114   

 
 
 
 

 

CLEANING 

 
Clean the external surfaces of the boiler regularly to maintain good hygiene 
Wipe external surfaces of the boiler with a damp cloth. Do not use abrasive materials on the outer 
surfaces. 

 

 

 

Содержание DB600-WTF

Страница 1: ...ee Model WMS6TF DB600 WTF Auto Fill Wall Mounted Boiler with Touch Free Dispense INSTALLATION AND USER INSTRUCTIONS Zip Water UK Ltd Trafalgar House Rash s Green Dereham Norfolk NR19 1JG Tel 0345 600...

Страница 2: ...IONAL FILTER MONITOR 8 PREVENTATIVE MAINTENANCE 8 CLEANING 8 MAINTENANCE SPARES SERVICE INFORMATION 9 SERVICE WARNINGS FAULT DIAGNOSTICS 9 10 GUARANTEE 10 INTRODUCTION Dear Customer Thank you for purc...

Страница 3: ...ance by a person responsible for their safety Children should be supervised to ensure they do not play with the appliance Always disconnect the unit from the power supply before servicing The unit mus...

Страница 4: ...age in LC Display Caution Boiling Water safety warning flashes as dispense is activated Includes easy fit spill tray bracket kit place cup on spill tray no need to hold whilst boiling water is dispens...

Страница 5: ...this work BASE ENTRY OF CABLE Use the cable gland Loosen cable gripping nut and pass cable through gland leaving enough free cable to connect to terminal block Tighten cable gland grip nut DO NOT SWIT...

Страница 6: ...pe must have a continuous fall and should not be longer than 300mm if a longer run is required use 22mm pipe to avoid airlocks The overflow pipe should have no more than four right angle bends and sho...

Страница 7: ...run through an initial self diagnostic check before starting to fill with water screen reads NOT READY FILLING Once primed with water the boiler will begin to heat screen reads NOT READY HEATING When...

Страница 8: ...sured amount into the cup teapot each time the touch free sensor is activated Top up feature At the end of the timed dispense cycle the CAUTION message will continue to flash for a further 5 seconds D...

Страница 9: ...lter counter With the required filter setting selected Press hold button long push for 4 seconds to save Press hold button long push for approximately 6 seconds until display goes blank Turn machine b...

Страница 10: ...lean the level sensing probes Flush with copious amounts of cold water to ensure all traces of de scaler are removed before SERVICE TECHNICAL SUPPORT SPARES To ensure your service enquiry is handled a...

Страница 11: ...faulty De scale tank and level sensors Isolate machine and wait 10mins then turn back on again Reduce temperature setting Call service if fault persists R E A D Y CHANGE FILTER OPTIONAL Filter cartrid...

Отзывы: