Delivery Checklist
Before starting installation, check that you have
the following parts;
• Catering Water Boiler
• Drip-tray
• Drip-tray fitting kit
• White water inlet hose (3/4”BSP connection)
• User instructions
Technical Specification
Model
CTS11F
(1501F)
CTS17F
(3001F)
CTS19F /6
(3001F/6)
Width
mm 243
243
243
Depth
mm 362
362
362
Depth with
drip-tray
mm 510
510
510
Height
mm 610
668
668
Power Rating KW 3.0
3.0
6.0
Weight
(Empty)
KG 13.2
14.4
14.8
Weight (Full)
KG 26
32.7
33.1
Water Inlet
Pressure:
Bar 2 to 7
2 to 7
2 to 7
Installation
The boiler must be installed on a level work
surface with sufficient strength to support
its weight. Ensure all vents are unobstructed.
Locate in an area where there is adequate space
to use the boiler safely (e.g. free from risk of
congestion and tripping hazards).
Connection to Mains Water Supply:
Connect the WRAS approved water filling hose
(3/4”BSP) to the inlet connection point on the
back of the boiler and the other end to the mains
water supply, via an accessible isolating tap with
a ¾”BSP thread*.
IMPORTANT:
If micro-bore pipe is used instead
of the inlet hose supplied, the size must be
minimum OD 3/8”(10mm)
The water supply must have a pressure not
exceeding 7bar (96psi), and no lower than 2bar
(20psi) NOTE: If your water pressure exceeds
7bar, fit a suitable pressure reduction valve.
We regret that Instanta cannot be held
responsible for any machine malfunctions if
the water pressure exceeds that stated. If in
doubt, consult your water supply company.
*To meet WRAS installation requirements, an
approved single-check valve providing back-
flow prevention protection, should be fitted
at the point of connection between the water
supply and the appliances.
NOTE:
Water that has been treated by the
Reverse Osmosis process can become
aggressive (due to lack of minerals or Ions),
and in extreme cases can cause leaching and
corrosion of pipes, fittings and other metal parts
within the appliance.
If the appliance is being fed by water treated by
Reverse Osmosis, we strongly recommend that
the water is tested regularly.
If you have any queries in this respect, please
contact our customer services team.
Electrical Connection:
The boiler must be Earthed.
3.0KW models: CTS11F (1501F) & CTS17F
(3001F)
Your machine is supplied with standard
13amp bonded plug with a 13amp fuse
6.0KW model: CTS19/6 (3001F/6)
Your
machines is supplied with a 1.5mtr cord [3-core
@ 4.0mm]. Wire to at least a 30amp supply via
an all-pole disconnection isolator switch (easily
accessible for safety). Only a qualified electrician
should undertake this work.
Overflow;
The drip-tray has a limited capacity and is
designed to handle small spillages and drips.
Wherever possible, we strongly recommend
that it is connected to a permanent waste outlet
using the fitting kit provided.
If preferred, and as an alternative, the
overflow can be connected from the back of
the machine using an optional rear-overflow
kit (Pt. No: ROFK1) available from Instanta
Spares Department (01704 502905).
IMPORTANT:
Whichever overflow connection is
chosen, the diameter of the pipe used must be
no less than 15mm.
Failure to connect the overflow-outlet to a
permanent waste of drain, could lead to property
damage from flooding.
If in all circumstances, it is absolutely not
possible to direct the boiler overflow-outlet to
3