FOR
USE
BY
QUALIFIED
PERSONNEL
ONLY
Operation
1.
Push
ON/OFF
switch to
ON
position.
2.
Set desired temperature (See Controller
Operation).
3.
Allow the machine to warm up until the selected
temperature is reached.
4.
Set the desired pressure by adjusting the air
pressure regulator.
5.
Select the desired timing cycle (See Controller
Operation).
6.
Place the substrate on lower platen, smoothing
out all wrinkles.
7.
Position transfer or lettering on substrate.
8.
Swing the upper arm into position directly over
the lower platen.
9.
Depress and hold both start buttons, one on
each side of the machine, simultaneously until
the lower platen contacts the upper platen.
The
start buttons must be held until the upper
and lower platens make contact.
At this point
the machine operation is fully automatic. The
platens seal the transfer to the substrate and
then release automatically at the end of the
selected timing cycle.
10. Swing away the upper platen to the opposite
side and remove substrate.
11. The
DISENGAGE
button may be pushed at
anytime deactivate the machine.
SAFETY DELAY FEATURE
For operator safety the machine
shall not operate unless the upper
platen has fully reached the left
hand position. An additional delay
has been incorporated in machines
running software 2.29 (see point 9).
Solid State Controller
This controller has three (4) control features:
1.
Temperature - Temperature may be set from
125 - 450
°
F (52-232
°
C).
2.
Time - Time may be set from 1 second to 10
minutes.
3.
Counter – Cycle counter counts the number of
applications from 1 to 9999 (see additional Notes
– Counter).
4.
Presets
‐
Five (5) presets that can be
programmed by the user. Each preset will retain
a temperature and time setting, i.e. Program #1
could be set for 325
°
F and 10 seconds while
Program #2 could be set for 375
°
F and 15
seconds. Once the five presets have been
programmed, the user need only press the
PGM
button several times until the desired program is
selected. The lit LED above the PGM button
indicates the selected program.
Note: there is
also a sixth setting that is indicated by no lit
LED's.
NOTE
Another substrate may be prepared
on the unused platen during the
sealing operation of the used
platen.
5
Содержание 907
Страница 1: ...MNL90000 Rev I 05 19 15 OPERATION AND MAINTENANCE MANUAL MODEL 907 ...
Страница 13: ...FOR USE BY QUALIFIED PERSONNEL ONLY 12 907 Wiring Diagram 0412 ...
Страница 14: ...FOR USE BY QUALIFIED PERSONNEL ONLY 13 ...
Страница 17: ...FOR USE BY QUALIFIED PERSONNEL ONLY Notes 16 ...
Страница 18: ...FOR USE BY QUALIFIED PERSONNEL ONLY 17 ...
Страница 19: ...FOR USE BY QUALIFIED PERSONNEL ONLY ...
Страница 20: ...FOR USE BY QUALIFIED PERSONNEL ONLY ...
Страница 21: ...FOR USE BY QUALIFIED PERSONNEL ONLY 17 ...