BMC Settings
8.6 Power and Fan
Select “Power and Fan” on the navigation tree to open the power supply and fan interface.
It contains the interfaces of power supply monitor, power supply configure,server power
control,power peak, power consumption andfan speed control, as shown in the following figures.
●
Power supply monitor: Contains PSU present state, alert, temperature, input power,
output power, input voltage, output voltage, input current, output current and firmware
version information.
●
Power supply configure: Contains PSU present state, current state and A/S mode switch
function.
●
Server power control: Contains the server’s power on/off and reset, as well as the power
policy on AC power loss.
●
Power peak settings: To enable or disable the power peak, and set the maximum random
time.
●
Power consumption: Dynamic power consumption.
●
Fan speed control: Contains fan status, current speed and speed control function.
Note:
Fan speed control contains the following speed levels:
Low: About 20% duty ratio
Medium: About 50% duty ratio
High: About 75% duty ratio
Full: 100% duty ratio