background image

checklist 

ALWAYS REMOVE THE POWER CORD FROM ITS RECEPTACLE 
BEFORE SERVICING THE HEATER. 

IF THE HEATER STOPS WORKING: 

1.   Check the circuit breaker supplying power to the outlet where the 

heater is installed. If the breaker has tripped, have the circuit 
checked by an electrician to determine if the circuit is overloaded, 
or if a short exists. 

2.   If the circuit breaker has not tripped, remove the power cord from 

its receptacle, remove the thermostat cover on the front of the 
heater, inspect the heater for any frayed or loose electrical 
connections, and push the red "reset" button at the top of the 
thermostat compartment. If the button "clicks" when pushed, 
something has caused the heater to overheat. Leave power cord 
unplugged and contact your service agency. 

3.   If the button does not "click" when pushed, the element has 

probably burned out and should be replaced. Contact your service 
agency. 

IF THE WATER OVERHEATS, OR IF STEAM IS RELEASED FROM 
THE RELIEF VALVE: 

1.  Unplug the power cord immediately. 

2.  Allow tank to cool. 

3. Remove the cover on the front of the heater and check that the 

thermostat is seated firmly against the front of the tank. and that the 
mounting bracket is snug, but not over tightened. 

4. If there are any continued signs of overheating, disconnect the 

power and contact a qualified service person. 

For the location of nearest factory authorized service agency call toll 
free: 1 -800-558-5700. 

RELIEF VALVE OPERATION 

If the relief valve weeps or drips hot water, contact a qualified service 
person. If a check valve is installed in the hot water line, an expansion 
tank must be properly installed. 

 
 
 
 
 
 
 
 
 
 
maintenance 

 
Periodically drain the tank to help prevent sediment buildup. See 
draining instructions. 

The temperature and pressure relief valve should be checked 
periodically to ensure it operates properly. Lift the lever at the top of 
the valve to see if the valve opens and closes properly. 

 

THE WATER PASSING OUT OF THE VALVE DURING THIS 
CHECK MAY BE EXTREMELY HOT. COLLECT DISCHARGE IN 
APPROPRIATE CONTAINER 
 
 
 
 
 
 
 
 
 
 
 

Содержание W-152

Страница 1: ... GROUNDING INSTRUCTIONS found plug if it is not working properly or if it has been damaged or on page 3 dropped 3 Install or locate this water heater only in accordance with the 8 This water heater should be serviced only by qualified service provided installation instructions personnel Contact nearest authorized service facility tor 4 Use this water heater only for its intended use as described i...

Страница 2: ... ELECTRICAL Rating Heater Power Cord THERMOSTAT INSULATION FITTINGS Water Inlet Outlet T P Relief Valve Not Supplied Drain STANDBY HEAT LOSS 120 F 75 F Ambient FIRST HOUR RATING 80 F Rise USABLE HOT WATER 1 2 GPM 25 Temp Drop 1 GPM 2 GPM SHIPPING WEIGHT OVERALL DIMENSION See Pg 8 W 152 W 154 150psi Max 150psi Max Bronze Bronze 2 1 2 Gallon 4 Gallon 1500 Watts 12 5 Amps 120 Volt Replaceable 1 screw...

Страница 3: ...NY RUST OR CORROSION DAMAGE CAUSED BY THE INSTALLATION OF INSULATION BLANKETS FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN SERIOUS PERSONAL INJURY OR DEATH GROUNDING INSTRUCTIONS This appliance must be grounded In the event of a malfunction or breakdown grounding provides a path of least resistance for electric current to reduce the risk of electric shock This appliance is equipped with a co...

Страница 4: ...R SHOULD BE EXAMINED BY A COMPETENT SERVICE PERSON BEFORE IT IS PLACED BACK IN OPERATION W 152 MOUNTING The W 152 model is designed for wall or floor mounting and the heater should be located within 3 112 feet of a grounded 120V electrical outlet Mount in an upright position only with the water connections at the top The model W 152 tank holds 2 1 2 gallons and weighs 34 Ibs when full Make sure wa...

Страница 5: ...MPERATURES OF 130 F OR LOWER SETTING THE TEMPERATURE HIGHER WILL INCREASE THE RISK OF SCALD INJURY If it is necessary to change the water temperature unplug the power cord and remove the front cover Adjust the thermostat temperature setting up or down replace the cover and reconnect the power cord See section Temperature Regulation ADJUST TEMPERATURE Heating element has a thermostat which is facto...

Страница 6: ...EATS OR IF STEAM IS RELEASED FROM THE RELIEF VALVE 1 Unplug the power cord immediately 2 Allow tank to cool 3 Remove the cover on the front of the heater and check that the thermostat is seated firmly against the front of the tank and that the mounting bracket is snug but not over tightened 4 If there are any continued signs of overheating disconnect the power and contact a qualified service perso...

Страница 7: ...am heater dimensions IMPORTANT THE CORD OF THIS HEATER MUST BE USED WITH A PROPERLY GROUNDED OUTLET TO INSURE PROPER SAFETY AND OPERATION DO NOT USE A 3 PRONG TO A 2 PRONG ADAPTER WATER HEATER IS NOT TO BE HARD WIRED ...

Страница 8: ...ed in steps 1 and 2 Our address is shown below IN SINK ERATOR LIMITED RESIDENTIAL WATER HEATER WARRANTY 5 YEAR LIMITED WARRANTY AGAINST TANK LEAKAGE IN SINK ERATOR warrants that the bronze tank in your IN SINK ERATOR water heater will not leak due to defects in material or workmanship for a period of five 5 years after date of original installation If during this five year period the tank leaks du...

Отзывы: