This control center was inspected and tested under 
operating conditions before shipment from the factory. 
In case of trouble, check the items listed below.

A.  Disposer motor will not start and water  

does not flow.

 

1.  No incoming line power, turn line power on.

  2.  Electric disconnect switch is not ON. Turn electric 

disconnect to ON position.

  3.  Electrical disconnect switch has been reactivated 

and 30-second delay has not yet expired. Wait 30 

seconds and try starting again.

  4.  Control circuit fuse FNA2 is blown. Replace fuse.

B.  Disposer motor stops while grinding but water 

continues to flow.

  1.  Control center wired for automatic shut-off. Press  

start button. If disposer runs for 10 minutes then 

shuts off, the automatic shutoff is active.  If the 

manual setting is desired, change as indicated in 

the feature section. 

  2.  Disposer is jammed. Press stop button and  

follow directions for unjamming that were  

supplied with the disposer.

3.  Disposer motor overload protector has tripped.

 

Follow instruction in C1.

C.  Disposer will not start but water flows.

1.  Overload protector on the disposer may have  

 

tripped. Press stop button. Locate red reset  

button on front of disposer electrical cover.  

Press to reset. If motor had been running, wait    

five minutes for the motor and overload to cool    

down before starting.

 

2.  Disposer is jammed. Press stop button and  

  follow directions for unjamming that were  

  supplied with the disposer.

PERSONAL INJURY

 • Allow only trained personnel to operate disposer.
 • Use baffles and guarding to avoid splashing and 

ejection of materials.

 • Do not put fingers or hands into the disposer.
 • When attempting to remove objects from a  

disposer, use long-handled tongs or pliers.

 • Turn power off before clearing a jam, removing  

an object from the disposer or pressing the  

red reset button.

PROPERTY DAMAGE 

Use only an FNA2 replacement fuse. Using another 

replacement fuse will result in product damage.  

ELECTRICAL SHOCK/PROPERTY DAMAGE

 • Troubleshooting other than what is recommended 

in this section should only be performed by  

qualified service personnel.

 • Further troubleshooting performed by untrained 

personnel could result in electric shock or damage 

to the control center.

 • All electrical checks must be performed by a  

qualified professional.

D.  Water flows constantly before start button  

is pushed.

1.  Water solenoid valve is installed backward.  

  Water flow should be in the direction of the arrow  

  on valve.

E.  Water flow does not decrease to 1 GPM.

1.  Incorrect solenoid valve combination 

connections. See Water Solenoid Valve, page 7.

2.  Incorrect trip point adjustment. See Current 

  Sensing Control Setup, page 8.

3.  Food load is present in disposer.

F.  Water flow does not increase.

1.   Insufficient food load is present.

2.   Incorrect trip point. See Current Sensing Control   

 Setup, page 8.

3.  Solenoid valve wiring incorrect in panel.
4.   More than two water solenoids wired into  

 

  system. System should have one solenoid with    

  a 1 GPM flow control and one solenoid with a  

  7 GPM flow control. 

NOTE: Use shutoff valves to adjust water flow for  

multiple trough or sink nozzles.

G.  Overload trips frequently.

1.   Do not overload disposer with excess amounts of  

  garbage and water (see disposer instructions for   

  recommended water flows).

Содержание AQUASAVER AS-101K

Страница 1: ...uses this appliance carefully reads and understands the Safety Instructions contained in this manual NOTICE is used to address practices not related to physical injury CAUTION indicates a hazardous si...

Страница 2: ...odel No AS 101K 8 380 460V 3 phase 1 2 10 HP 12 Warranty FOODSERVICE DISPOSER CONTROL CENTER LIMITED WARRANTY InSinkErator Foodservice Disposer Control Centers are warranted against defects in materia...

Страница 3: ...Erator Foodservice Disposers See Table 1 for approved disposer and control center combinations and Table 2 for electrical specifications The control center operates the disposer and control center com...

Страница 4: ...cked separately The solenoid valve is supplied with a 24 V coil Make certain that the valves are plumbed according to the water flow direction arrows marked on the valve or the valves will not functio...

Страница 5: ...und Lug Control Center Connection To Power Supply 4 5 6 7 Figure 4 Incoming 208 240 V Single Phase Line Power 24V Water Solenoid 1 GPM Flow Control 24V Water Solenoid 7 GPM Flow Control L1 L2 L3 L1 L2...

Страница 6: ...ol center uses low voltage 24 V to operate contactor coils solid state control circuit push buttons and solenoid valves Red wires denote a 24 V circuit WATER SOLENOID VALVE Two 24 V solenoid valves ar...

Страница 7: ...is completed Mid setting is approximately 45 seconds 2 With the disposer running at high water flow a Adjust the trip point control to maximum position the light is not illuminated b Turn the trip po...

Страница 8: ...arding to avoid splashing and ejection of materials Do not put fingers or hands into the disposer When attempting to remove objects from a disposer use long handled tongs or pliers Turn power off befo...

Страница 9: ...conform to local electrical codes All control centers and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the co...

Страница 10: ...All control centers and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the control center PROPERTY DAMAGE Ensure...

Страница 11: ...All control centers and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the control center PROPERTY DAMAGE Ensure...

Страница 12: ...All control centers and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the control center PROPERTY DAMAGE Ensure...

Отзывы: