InSinkErator AQUASAVER AS-101K Скачать руководство пользователя страница 5

5

24V Water Solenoid
1 GPM Flow Control

24V Water Solenoid
7 GPM Flow Control

2

3

4

6

7

7

13

Disposer

14

M1/M3

M4/M6

M2

M5

M7

NC

NC

1

3

2

L1

L2

L1

L2

On

Off

Neutral

Hot

Pre-wired in

panel to 

contactors

Power Supply

Motor Leads

Panel Ground Lug

Control Center Connection
To Power Supply

4 6

5

7

Figure 3. Incoming 120 V Single Phase Line Power

24V Water Solenoid
1 GPM Flow Control

24V Water Solenoid
7 GPM Flow Control

2

3

4

6

7

7

13

Disposer

14

M1

M3/M4

M2

M5

M6

M7

NC

1

2

3

L1

L2

L1

L2

On

Off

Neutral

Hot

Pre-wired in

panel to 

contactors

Power Supply

Motor Leads

Panel Ground Lug

Control Center Connection
To Power Supply

4

5

6

7

Figure 4. Incoming 208-240 V Single Phase Line Power

24V Water Solenoid
1 GPM Flow Control

24V Water Solenoid
7 GPM Flow Control

L1

L2

L3

L1

L2

L3

On

Off

Hot

Pre-wired in

panel to 

contactors

Power Supply

Panel Ground Lug

2

3

4

6

7

7

13

14

NC

M1

M2

M3

Disposer

M1

M2

M3

1

4

7

5

6

9

MOTOR LEAD WIRE#

M1 M2 M3

8

2

3

10 11 12

Figure 6. Incoming 380-460 V Three Phase Power

24V Water Solenoid
1 GPM Flow Control

24V Water Solenoid
7 GPM Flow Control

L1

L2

L3

L1

L2

L3

On

Off

Hot

Pre-wired in

panel to 

contactors

Power Supply

Panel Ground Lug

2

3

4

6

7

7

13

14

NC

M1

M2

M3

Disposer

M1

M2

M3

M1

M2 M3

1

4

10

5

6

12

MOTOR LEAD WIRE#

11

7

2

8

3

9

Figure 5. Incoming 208-240 V Three Phase Line Power

Electrical Connection Diagrams

Содержание AQUASAVER AS-101K

Страница 1: ...uses this appliance carefully reads and understands the Safety Instructions contained in this manual NOTICE is used to address practices not related to physical injury CAUTION indicates a hazardous si...

Страница 2: ...odel No AS 101K 8 380 460V 3 phase 1 2 10 HP 12 Warranty FOODSERVICE DISPOSER CONTROL CENTER LIMITED WARRANTY InSinkErator Foodservice Disposer Control Centers are warranted against defects in materia...

Страница 3: ...Erator Foodservice Disposers See Table 1 for approved disposer and control center combinations and Table 2 for electrical specifications The control center operates the disposer and control center com...

Страница 4: ...cked separately The solenoid valve is supplied with a 24 V coil Make certain that the valves are plumbed according to the water flow direction arrows marked on the valve or the valves will not functio...

Страница 5: ...und Lug Control Center Connection To Power Supply 4 5 6 7 Figure 4 Incoming 208 240 V Single Phase Line Power 24V Water Solenoid 1 GPM Flow Control 24V Water Solenoid 7 GPM Flow Control L1 L2 L3 L1 L2...

Страница 6: ...ol center uses low voltage 24 V to operate contactor coils solid state control circuit push buttons and solenoid valves Red wires denote a 24 V circuit WATER SOLENOID VALVE Two 24 V solenoid valves ar...

Страница 7: ...is completed Mid setting is approximately 45 seconds 2 With the disposer running at high water flow a Adjust the trip point control to maximum position the light is not illuminated b Turn the trip po...

Страница 8: ...arding to avoid splashing and ejection of materials Do not put fingers or hands into the disposer When attempting to remove objects from a disposer use long handled tongs or pliers Turn power off befo...

Страница 9: ...conform to local electrical codes All control centers and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the co...

Страница 10: ...All control centers and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the control center PROPERTY DAMAGE Ensure...

Страница 11: ...All control centers and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the control center PROPERTY DAMAGE Ensure...

Страница 12: ...All control centers and disposers must be carefully and permanently grounded A properly fused disconnect must be installed at the electrical supply source for the control center PROPERTY DAMAGE Ensure...

Отзывы: