8
CC-202D-5
120 V
1-phase
1/2 to 2 HP
ELECTRICAL SHOCK
• Turn off the electrical supply to the disposer before
attempting any work on it. Use a voltmeter or
circuit tester to ensure that power is off.
• Installation must conform to local electrical codes.
• All control centers and disposers must be carefully
and permanently grounded.
• A properly fused disconnect must be installed at
the electrical supply source for the control center.
PROPERTY DAMAGE
• Ensure that the control center voltage and phase
match the disposer motor and electrical supply.
Check nameplates on disposers and control
centers for voltage and phase specification.
• The disposer motor wiring connection is shown in
the disposer terminal box.
Call Toll Free 1-800-845-8345
for the nearest InSinkErator
Authorized Service Agency or
to reach Technical Support.
Note:
• Red wires = Low voltage (24 V) control.
• Black wires = Line voltage (208 - 240 V) control.
CC-202D-5 Wiring Diagram