MOUNTING THE CONTROL CENTER
Use the flanges at the back of the control center
enclosure and only mount panel in the upright vertical
position (door hinge is on the left). See Figure 1.
Locate control center within sight of disposer
per local codes.
If box is mounted to the sink table, recess the box so
that the buttons do not extend beyond the table's edge.
Introduction/Features/Mounting the Control Center
Figure 1. Control Center Dimensions
INTRODUCTION
The CC-202D Control Center is CUL
®
US listed for use
with InSinkErator Foodservice Disposers. See Table 1
for approved disposer and control center combinations
and Table 2 for electrical specifications. The control
center operates the disposer. Its main functions are:
• To start and stop the disposer.
• To reverse the direction of the disposer motor
automatically upon restart.
• To start the water flow to the disposer.
FEATURES
AUTOMATIC REVERSE
The disposer motor will reverse its direction of rotation
automatically upon restart. To avoid motor damage,
a five second delay feature prevents reversing while
motor is coasting.
ENCLOSURE
Stainless steel NEMA 4 construction.
PUSH BUTTON OPERATION
Push Black button to start disposer.
Push Red button to stop disposer.
Table 1. Approved Disposer and Control Center Combinations
Model
Waste Disposer Model
CC-202D-5
CC-202D-6
SS50-26, SS75-27, SS100-28, SS125-25,
SS150-34, SS150-38, SS200-27, SS200-31
CC-202D-7
CC-202D-8
SS50-27, SS75-28, SS100-29, SS125-26,
SS150-36, SS150-39, SS200-29,
SS200-32, SS300-25, SS300-27,
SS500-28, SS500-30, SS750-13,
SS750-15, SS1000-10, SS1000-12
Table 2. Electrical Specifications
Model
Part No.
Voltage
Phase
HP
CC-202D-5
15257
120V
1
1/2-2
CC-202D-6
15257A
208/240V
1
1/2-2
CC-202D-7
15257B
208/240V
3
1/2-10
CC-202D-8
15257C
380/460V
3
1/2-10
PROPERTY DAMAGE
The Control Center should only be used with an
InSinkErator Foodservice Disposer. The Control
Center voltage and phase should match the disposer.
The disposer current and horsepower should be
equal to or less than the Control Center rating.