background image

www.insigniaproducts.com

24

2

Apply window sealing foam to the side arm foam block as shown. Note that the window sealing foam attaches to the 
side next to your air conditioner.

3

Insert a side arm foam block into the side arm hinge until the top front of the side arm foam is flush with the top of the 
hinge.

4

Repeat steps 1 through 3 for the left side of your air conditioner.

5

Remove the two 1/2 in. screws from the top left and right sides of your air conditioner.

CAUTION

: The factory installed 1/2 in. screws must be re-used to secure the anti-tip brackets. Failure to use these screws could result 

in damage to your air conditioner.

Window sealing foam

Window sealing foam

Side arm foam block

Side arm foam block

Additional side 
arm foam

Air conditioner

Air conditioner

Vinyl window with lipped sill

Wooden window with flat sill

Side arm foam block

Top

Front

Side arm 
foam block

Note

: The “front” of the side arm 

foam block goes toward the inside 
of the house.

Содержание NS-AC8WU3

Страница 1: ...Before using your new product please read these instructions to prevent any damage USER GUIDE 8 000 BTU Window Air Conditioner NS AC8WU3 ...

Страница 2: ...tip brackets 23 Using your air conditioner 27 Using your air conditioner for the first time 27 Turning your air conditioner on off 27 Selecting an air conditioner mode 27 Selecting the fan speed 27 Using ECO energy saver mode 27 Setting the timer 27 Using the remote as a thermostat I SENSE 28 Using the check filter reminder 28 Using sleep mode 29 Turning the display on or off 29 Locking air condit...

Страница 3: ...ause electric shock Do not allow water to run into electric parts It may cause failure of machine or electric shock Do not use the socket if it is loose or damaged It may cause fire and electric shock Do not use the power cord close to heating appliances It may cause fire and electric shock Do not damage or use an unspecified power cord It may cause electric shock or fire If the power cord is dama...

Страница 4: ...upply by taking the power plug out and contact a qualified service technician This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ens...

Страница 5: ...n who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry accredited assessment authority which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requi...

Страница 6: ...ents Be sure the air conditioner is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circu...

Страница 7: ...n should safely disperse any released refrigerant and preferably expel it externally into the atmosphere H Checks to the refrigeration equipment Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the manufacturer s maintenance and service guidelines shall be followed If in doubt consult the manufacturer s technical departme...

Страница 8: ...se of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe work If a leak is suspected all naked flames shall be removed extinguished If a leakage of refrigerant is found which requires brazing all of the refrigerant shall be recovered from the system or isolated by means of shut off valves in a part of the system remote from th...

Страница 9: ... there are labels on the equipment stating the equipment contains flammable refrigerant 16 Recovery When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrigerant recovery cylinders are employed Ensure that the correct numbe...

Страница 10: ...nt of a power outage 4 9 ft 1 5 m power cord easily reaches nearby outlets Simple white color looks modern and matches any décor Package contents Window air conditioner Mounting hardware Remote control AAA batteries 2 User Guide Tools required Installation hardware Indicates extra hardware provided in a separate bag 1 2 in Type B Screw 2 1 4 in Type B Screw 2 1 2 in Type A Screw 3 1 in Type A Scre...

Страница 11: ...sh Foam 1 Window Sealing Foam 1 Bracket Sealing Foam 1 Additional Side Arm Foam 2 Note Save the carton and these instructions for future reference The carton is the best way to store your air conditioner during the winter or when not in use Mounting slot Air outlet Control panel Air input Main support Rear cross brace Left extension arm Right extension arm Spring push pin Horizontal bracket Angled...

Страница 12: ...AN modes The fan will continue to run for three minutes after the compressor shuts off The fan then cycles on for two minutes at 10 minute intervals until the room temperature is above the set temperature at which time the compressor turns back on and cooling resumes The indicator LED turns on to show that ECO mode is on 5 MODE button and Mode indicator LEDs Press to change the air conditioner mod...

Страница 13: ...utomatically reminds you the LED above the button turns on to clean the air filter after 250 hours of operation 10 power button Press to turn your air conditioner on or off The Energy Saver function is automatically initiated in Cool Dry and Auto modes ITEM DESCRIPTION 1 temperature time indicator Displays the room temperature or the set temperature In Timer mode displays the time 2 Mode indicator...

Страница 14: ...ights when auto mode is selected 2 Timer on indicator Lights when timer is on 3 COOL mode indicator Lights when cool mode is selected 4 Timer off indicator Lights when timer is off 5 DRY mode indicator Lights when dry mode is selected 6 Horizontal louver swing indicator Lights when the horizontal louver swing is on 7 Vertical louver swing indicator All of the LEDs turn on when the remote is turned...

Страница 15: ...t temperature In Timer mode displays the time 21 Remote control on indicator Lights when the remote control is on Notes The remote control must be pointed at your air conditioner and used within 26 2 ft 8 m Your air conditioner will beep when the remote control signal is received Curtains other materials and direct sunlight can interfere with the infrared signal receiver Notes Do not mix old and n...

Страница 16: ...inances Note to Consumer Keep these instructions for future reference Note to Installer Be sure to leave these instructions with the Consumer Completion time Approximately one hour Skill level Installation of this appliance requires basic mechanical skills We recommend that two people install this product Proper installation is the responsibility of the installer Product failure due to improper in...

Страница 17: ...ided 1 type A screws Refer to Step 2 Installing the support bracket on page 18 Installing your air conditioner Step 1 Preparing the support bracket 1 Remove your air conditioner support bracket and hardware from the box and place on a flat surface 2 Remove the packing material 3 Find the center of your window and lightly mark it with a pencil 4 Press the left spring push pin and adjust the left ex...

Страница 18: ... conditioner is being installed 2 Place the main support bracket into the window opening making sure that the horizontal bracket and extension arms are located on the indoor side of the window CAUTION Maintain control of the bracket until the installation is complete Apply bracket sealing foam Bottom view Apply bracket sealing foam Apply bracket sealing foam Indoor side of window ...

Страница 19: ...sill secure the bracket to the windowsill by drilling 1 8 in pilot holes and securing the bracket to the window with the 1 2 type A screws Note If the gap between the bracket and the window sill exceeds 3 16 in 5 mm the bracket may be deformed while securing the 1 type A screws you can add a block to reduce the gap if possible Wooden window Outside Outside Vinyl window Inside Inside 1 in type A sc...

Страница 20: ...main support pin through the holes in the main support and angled support arm 7 Using the numbers on the main support repeat the adjustment for the other angled support arm matching the hole number from the first support arm 8 Check the level again and make sure that the bracket is secure If further adjustment is required use alternate holes where the main supports attach to the horizontal bracket...

Страница 21: ...g foam Step 3 Installing your air conditioner on the support bracket 1 Measure the width of your window track the vertical track your window slides up and down in If it measures 1 2 or less flip the anti tip bracket so that the small end faces out then continue with your air conditioner installation CAUTION Do not leave your air conditioner unattended during installation Bracket sealing foam Brack...

Страница 22: ... align with the main supports Using a level check for proper tilt towards the outside 3 Pull the window down into the slot on top of your air conditioner to help align it correctly Keep the window partially inserted into the slot to help support your air conditioner during installation 4 Fold down both side arm hinges Window Sidearmhinge Sidearm hinge ...

Страница 23: ...am and anti tip brackets 1 Measure the distance between the right side arm hinge and the closest part of the window frame Add 1 4 in to this distance and cut the side arm foam block to width WARNING Failure to install the open window brackets could cause injury or property damage CAUTION Do not leave your air conditioner unattended during installation 1 2 in type B screw 1 4 in type B screw Measur...

Страница 24: ... Remove the two 1 2 in screws from the top left and right sides of your air conditioner CAUTION The factory installed 1 2 in screws must be re used to secure the anti tip brackets Failure to use these screws could result in damage to your air conditioner Window sealing foam Window sealing foam Side arm foam block Side arm foam block Additional side arm foam Air conditioner Air conditioner Vinyl wi...

Страница 25: ...mall gaps between the window and your air conditioner then close the window and check for gaps 9 Fill any gaps with the included foam as needed 10 Extend the integrated window locks located in the U channel until they contact the window For additional security you can install the optional sash lock 11 To secure the lower sash in place attach the right angle sash lock with 1 2 in type A screws Exte...

Страница 26: ...nsert them in the space between the upper and lower sashes 13 As a final check review the installation and check for any gaps or openings Seal any gaps with additional sealing foam provided to make sure that there are no leaks Check for leaks here Check for leaks here ...

Страница 27: ...ture Selecting the fan speed Press the FAN button repeatedly to cycle through the available fan speeds Choices include Auto Low Med or High In Dry mode the fan speed is set to Low automatically Using ECO energy saver mode While using the ECO mode the fan runs for three minutes after the compressor shuts off then cycles on for two minutes at 10 minute intervals When the room temperature is above th...

Страница 28: ...u want your air conditioner to run press up down to adjust the delay time from 0 5 10 hours in half hour increments then 10 24 hours in one hour increments 3 Press TIMER OFF again The number next to Timer On blinks 4 To set how long to wait before your air conditioner turns on press up down to adjust the delay time from 0 5 10 hours in half hour increments then 10 24 hours in one hour increments T...

Страница 29: ... for five seconds to lock the remote control s settings so that they cannot be changed Press I SENSE and TIMER OFF for two seconds again to unlock the remote control Controlling air flow The louvers on the front of your air conditioner let you direct the air flow up or down and left or right throughout the room as needed Press the SWING button until the desired up down direction is obtained Move t...

Страница 30: ...conditioner If you plan to store your air conditioner during the winter remove it carefully from the window see Removing your air conditioner from the window on page 30 and cover it with plastic or return it to its original box Removing your air conditioner from the window 1 Turn your air conditioner off and disconnect the power cord 2 Remove the sash sealing foam from between the windows then uns...

Страница 31: ...tional louvers are positioned improperly Position the louvers for better air distribution The front of your air conditioner is blocked by drapes blinds or furniture restricting air distribution Clear the blockage in front of your air conditioner Doors windows or registers are open allowing cold air to escape Close any open doors windows or registers Your air conditioner recently turned on in a hot...

Страница 32: ...pproved by the party responsible for compliance could void the user s authority to operate the equipment This equipment complies with Industry Canada radiation exposure limits set forth for an uncontrolled environment California Residents WARNING Cancer and reproductive harm www p65warnings ca gov The room is too cold The set temperature is too low Raise the set temperature There is a chemical sme...

Страница 33: ...spoilage Customer instruction education Installation Set up adjustments Cosmetic damage Damage due to weather lightning and other acts of God such as power surges Accidental damage Misuse Abuse Negligence Commercial purposes use including but not limited to use in a place of business or in communal areas of a multiple dwelling condominium or apartment complex or otherwise used in a place of other ...

Страница 34: ...rmation below 1 877 467 4289 www insigniaproducts com INSIGNIA is a trademark of Best Buy and its affiliated companies Distributed by Best Buy Purchasing LLC 7601 Penn Ave South Richfield MN 55423 U S A 2022 Best Buy All rights reserved V1 ENGLISH 21 0893 ...

Отзывы: