background image

 

www.insigniarange.com

 

Last Modified: 27/01/2017

 

 21 

Control Panel Instructions

 

Button 1 (Lights) 

 

Press x1 for lights and once again to turn the lights off. 

 

 

 

Button 2 (Steam) 

 

To start the steam function, simply press the steam button (which looks like a cloud).

 

Press the 

M

” 

button to bring up the temperature setting (in the top corner you will see a temperature symbol). 

Then use the up and down arrows to change the temperature of your steam.

 

Continue to press the 

M

” 

button again to set the steam timer (to the side you will see 

min

”) 

and use the arrows to 

select your desired time. Finally press the 

M

” 

button again to finish setting the timer.   

 

 

Button 3 (Up Arrow) 

 

Radio search (higher frequency)

 

music track (next song) 

 

volume increase.

 

 

Button 4 (Audio select) 

 

To tune your radio channels firstly press the Audio Select button (which looks like a musical note and a Bluetooth 

symbol). 

 

Then once the radio is on press and hold the 

M

” 

button until it starts scrolling. 

 

Finally, once the panel has finished scrolling then use the up and down arrows to cycle through all the radio 

stations that were found.

 

To connect a device via Bluetooth, press the music function button twice (which looks like a musical note and a 

Bluetooth symbol), the control panel will show 

INS

”. 

 

Then simply go on your device and pair up with the shower which will be named as 

INS

”. 

 

While your Bluetooth device is connected, use the music function button to pause and resume your 

music. (further details can be found on the next page) 

 

 

 

To see our tutorial videos for operating this control panel

s features, 

please search for 

Insignia Showers

” 

on YouTube and find our 

SUN 

Control Panel

” 

Playlist, or you can 

click here

 

1

 

2

 

3

 

4

 

5

 

6

 

 7

 

8

 

Содержание INS9012

Страница 1: ...code to hand before calling Replacements Parts inside of your warranty contact www insigniarange co uk customerService aspx Spares Replacements Parts outside of your warranty contact 0844 800 3069 www insigniarange co uk WARRANTY REG NO __________________________ to claim your full 5 year warranty register your shower within 90 days at www insigniarange co uk warrantyreg aspx CHECK ALL CONTENTS BE...

Страница 2: ...quirements What s In The Boxes Screw Pack Contents Plumbing Requirements Schematics Starting The Installation Electric Box Connections Steam Generator Connections Sealing and Water Testing Sun Control Panel Instructions Help Book Information Parts List 3 5 7 8 9 10 11 17 19 20 21 24 25 ...

Страница 3: ...any years to come Like everything in order to obtain a first class product that will serve you well for many years the effort and correctness put into the assembly will reflect in the quality of your finish OUR BADGE RATING IN TERMS OF DIFFICULTY OF ASSEMBLY IS BASED ON CLIENT FEEDBACK 1 Badge Very easy 2 Badges Easy 3 Badges Moderate 4 Badges Harder than average 5 Badges Professional skills requi...

Страница 4: ...ED ELECTRICAN COMPANY TO COMPLETE THE CONNECTION FROM SHOWER TO THE HOUSE SUPPLY LAWS DEMAND IN MANY CASES YOU DO THIS AND YOUR WARRANTY IS VOID IN REGARDS TO THE ELECTRICAL ITEMS IF THIS IS NOT UNDERTAKEN YOURS AND OTHERS SAFETY IS PARAMOUNT NEVER ATTEMPT THIS YOURSELF REMEMBER These showers are designed to be free standing and movable from their location should you have the need to replace anyth...

Страница 5: ...onsumer service box Remove the fitted plug and ensure the Consumer unit has capabilities to replace RCD feature if RCD is removed Always use protection against electrical surge Your shower should be treated the same as a home computer A surge protector should eradicate the possibility of either the transformer or computer control being burnt out Please note earth is required and found on chassis o...

Страница 6: ...one Gun Spirit Level Tape Measure Philips Screwdriver Electric Drill Adhesive Requirements Bacteria Resistant Sanitary Silicone for vertical joints RubberGum Plumbers Mait for waste joints Not Supplied Supplied x 2 Not Supplied Hardware Requirements A Steam Shower requires 3 x 1 Metre Braided Hose Not Supplied ...

Страница 7: ...placement missing parts can be obtained free of charge during or after the build Any claims can only be within the timescale permitted 48 hours after delivery and always BEFORE build Product Code Description Quantity SP097 Door Handles 2 SP008 Door Wheels 8 ST20 20mm Screws 10 ST35 35mm Screws 10 ST14 14mm Screws Not Used 6 ST25 25mm Screws 10 SW9 Small Washers 20 DB9 Drill Piece 1 Note In some ca...

Страница 8: ...eans you do not silicone anything just simply construct the shower align drill and screw everything together Once you are happy with the build take the unit apart and carry out the final fix What s In The Boxes Tray Box 1x Tray 1x Roof 2x Curved Rails 2x Accessory box Glass Room 2x Door seals 2x Glass doors 2x fixed glass Column 1x Complete Column Backwalls 1x Left Panel Backwall 1x Right Panel Ba...

Страница 9: ...er plumber The end delivery however must fall within the scope above Important Note Do not exceed 3 4 BAR pressure under any circumstances Warranty is void if so as damage will occur If you have a combi sup ply please use a pressure reducing valve if required to lower the BAR pressure to the shower Please Remember that this product is free standing and is designed to be pulled away from the wall T...

Страница 10: ...www insigniarange com Last Modified 27 01 2017 10 INS9012 ...

Страница 11: ...t cases this is blanked yet should you have a steam version you need to gently drill this out as this item is for the steam generator drainage and will be connected in the instructions later Now please level the tray by firstly placing the tray in its final location and then using a spirit level adjust the tray feet accordingly Once you are happy with the levelling of the tray you can pull it out ...

Страница 12: ...n by the arrows Step 3 The next step is to attach both front uprights and the top rail In order to do this insert the front uprights over the glass seal as push on tightly as directed by the arrows in the image Now attach the top rail wide rail with logo and then screw into place using the ST35 screws Once the top rail is in place secure the front uprights to the top and bottom rails from inside t...

Страница 13: ...age now apply RubberGum along the bottom of the panels before walking the panel around to the position shown in the image marked 2 Now repeat for the other side 1 2 1 Step 5 Now you have locked the two back panels in position align the back panels to the central column Once you are happy with the alignment run a bead of silicone up the edge of the panels and screw all parts to gether using the ST2...

Страница 14: ...stable wheels to the top and bottom of the glass doors and ensure the wheels are at their lowest position and hang on the inner curved rails with the wheels facing the outside of the glass Once all wheels are fitted and on the rails you can adjust the wheels by turning the plastic bolt clockwise in which in turn will pull the wheels towards the track ensuring a secure a tight fit Now grease the tr...

Страница 15: ... shelf into your shelf brackets and secure by tightening the grub screw situated on the bottom of the bracket Accessory Installation Please Note Ensure all grey backing film on the rear of the glass panels are pierced through the existing glass holes with a knife to provide an efficient smooth fitting and location of the accessories We recommend using a screwdriver on the smaller holes Please see ...

Страница 16: ...roughly 6mm into the cabin and run clear silicone around the rear side of the probe Ozone o3 Unscrew the chrome pepper pot end and drop the white box upside down into the rear hole as shown in the image Now from the inside of the shower re attach the chrome pepper pot end and tighten Monsoon Head Attach the grey hose from your valve to the inner black tube using PTFE tape please note this only nee...

Страница 17: ...differ from the image Please refer to your outer chrome faceplate in side your Insignia shower as a reference point IF YOUR DIAL DOES NOT CORRESPOND TO THE APPROPRIATE DEVICE Turn on your water to the shower and note which output the water exits from then turn off the water and swap over the relevant hose Alternatively remove the outer chrome knob by removing the chrome cap and loosening the grub ...

Страница 18: ...r allow children to use the steam function This function is for ADULTS ONLY Always be aware of the steam outlet pod position Never use in close proximity to the person using it Never use this shower if you have been drinking alcohol Never use with more than one person unless the shower is designed for this This product is not to be used for washing bathing animals Always turn power supply off afte...

Страница 19: ...e white steam pod within your shower Make sure these are fitted in the correct position as they are only attached for transportation reasons only Water Inlet Connect a braided hose from the shower valve s centre feed to this opening Drain Connect the grey rubber hose from the steam generators drain opening to the nozzle on the shower waste as shown in the below image ...

Страница 20: ... joint factory seal hose clip and jet by walking from one side and going around to the back and then to the other side finishing at the front If you have a small leak normally caused through insuf ficient sealer or air bubble on assembly dry the area thoroughly and reseal Please remember the location of the water may not be exactly where the leak is as it could have run around to a low point Never...

Страница 21: ...select To tune your radio channels firstly press the Audio Select button which looks like a musical note and a Bluetooth symbol Then once the radio is on press and hold the M button until it starts scrolling Finally once the panel has finished scrolling then use the up and down arrows to cycle through all the radio stations that were found To connect a device via Bluetooth press the music function...

Страница 22: ... radio channels firstly press the Audio Select button which looks like a musi cal note and a Bluetooth symbol Tuning your radio channels Step1 To connect a device via Bluetooth press the music function button twice which looks like a musical note and a Bluetooth symbol the control panel will then show INS Step2 Then once the radio is on press and hold the M button until it starts scrolling Step3 F...

Страница 23: ...unlock the panel Please Note When the control panel is locked none of the buttons will work except the unlock key Button 7 Down Arrow Radio search lower frequency music track previous song volume decrease Button 8 Power Button Simply press the power button to switch on your control panel and once more to switch off your control panel Once your control panel has been switched off the 03 system will...

Страница 24: ...www insigniarange com Last Modified 27 01 2017 24 Need Help If so then simply download Insignia s free comprehensive help and troubleshooting brochure now Simply visit www insigniarange co uk help aspx ...

Страница 25: ... seals Part Code Part Description SP300 Waste hose SP301 White insulated pipe SP187 Drain Hose SP234 Vertical steam generator SP308 Magnetic door seals SP310 Rear door seals SP173 SP095 SP044 SP182 SP043 3 port 3 feed thermo static valve 3 Port Selector Cartridge On Off Water Mixer Valve Vernet Screw Fit Ther mostatic Cartridge Plastic Thermostatic Valve Safety Lock Ring SP039 Fan Model Dependent ...

Страница 26: ...e used in any way shape or form with out written permission from Maclean International Ltd Images are NOT permitted to be saved printed or uploaded Violation of copyright laws are punishable by law All images are registered with ImageTraker Insignia is a registered trademark of Maclean International Ltd ...

Отзывы: