background image

 

www.insigniarange.com

 

Last Modified: 03/04/2018

 

 12 

Step 3

 

Push the 

U Shape

” 

glass seal onto the glass panel prior to insertion into the 

frames. Please ensure the thin seal is on the entrance side of the panels with 

the thicker to the rear side.

 

 

The next step is to attach both front fixed glass panels. In order to do this 

take the glass panel (the large black edge to be situated on the entrance 
side to the shower) and offer it up to the upright as shown by the arrows.

 

Step 2 

 

The next step is to attach the uprights (

maybe pre

-

fitted to the front fixed glass see 

above) 

to the curved rails using the 

ST35 

screws. The end with the groove is 

designed to sit on the tray, with the flat end connecting to the roof. Please note the 

U

’ 

shaped channel is meant to face inwards to allow the glass to fit correctly.

 

(wider rail with Insignia logo at the top)

 

PLEASE NOTE

 

The screw head needs to bypass the OUTER hole. If this does not occur please bore 

out the outer hole only by about 2

-

4mm

 

Thick glass seal on outer side

 

Thin glass seal on inner side

 

IMPORTANT

 

If your front fixed glass has 2 black uprights pre

-

fitted please bypass steps 3 and 4 

 

Please note the wide upright is the outer upright and the cut out sits on the tray side.

 

Содержание INS003

Страница 1: ...ts Parts inside of your warranty contact www insigniarange co uk customerService aspx Spares Replacements Parts outside of your warranty contact 0844 800 3069 www insigniarange co uk WARRANTY REG NO __________________________ To claim your full 5 year warranty register your shower within 90 days of delivery at www insigniarange co uk warrantyreg aspx Standard 12 month warranty applies if outside t...

Страница 2: ...on Electrical Requirements What s In The Boxes Screw Pack Contents Plumbing Requirements Schematics Starting The Installation Control Panel Connections Sealing and Water Testing SUN Control Panel Instructions Help Book Information Part list 3 5 7 8 9 10 11 19 20 21 22 23 ...

Страница 3: ...any years to come Like everything in order to obtain a first class product that will serve you well for many years the effort and correctness put into the assembly will reflect in the quality of your finish OUR BADGE RATING IN TERMS OF DIFFICULTY OF ASSEMBLY IS BASED ON CLIENT FEEDBACK 1 Badge Very easy 2 Badges Easy 3 Badges Moderate 4 Badges Harder than average 5 Badges Professional skills requi...

Страница 4: ...ED ELECTRICAN COMPANY TO COMPLETE THE CONNECTION FROM SHOWER TO THE HOUSE SUPPLY LAWS DEMAND IN MANY CASES YOU DO THIS AND YOUR WARRANTY IS VOID IN REGARDS TO THE ELECTRICAL ITEMS IF THIS IS NOT UNDERTAKEN YOURS AND OTHERS SAFETY IS PARAMOUNT NEVER ATTEMPT THIS YOURSELF REMEMBER These showers are designed to be free standing and movable from their location should you have the need to replace anyth...

Страница 5: ...te for electrician This product comes with 3 amp plug We leave it this way for you to connect this your own way due to continued additions to current regulations 1 Connect within current laws and IP directives 2 Preferred Wire into isolated fused feed connecting directly to the house consumer service box Always use protection against electrical surge Your shower should be treated the same as a hom...

Страница 6: ...quirements Bacteria Resistant Sanitary Silicone for vertical joints RubberGum Plumbers Mait for waste joints Not Supplied Supplied Not Supplied Hardware Requirements A Hydro Massage Shower requires 2 x 1 Metre Braided Hose Not Supplied Safety Gloves Safety Glasses PREVENT INJURIES This product may contain sharp edges Assemble using gloves Use safety glasses when handling glass or drilling ...

Страница 7: ...is assembled When we use the word DRY RUN this means you do not silicone anything just simply construct the shower align drill and screw everything together Once you are happy with the build take the unit apart and carry out the final fix What s In The Boxes Tray Box 1x Tray 1x Roof 2x Curved Rails 1 x Accessory Box Glass Room 2x Door seals 2x Glass doors 2x fixed glass Column 1x Complete Column B...

Страница 8: ...be obtained free of charge during or after the build Any claims can only be within the timescale permitted 48 hours after delivery and always BEFORE build Product Code Description Quantity SP097 Door Handles 2 SP276 SP276A Twin Chrome Wheels Twin Chrome Wheels Push Button 4 4 ST12 12mm Screws 18 ST20 20mm Screws 14 ST35 35mm Screws 10 ST10 10m Screws 5 ST25 25mm Screws 5 SW9 Small Washers 28 DB9 D...

Страница 9: ...er plumber The end delivery however must fall within the scope above Important Note Do not exceed 3 4 BAR pressure under any circumstances Warranty is void if so as damage will occur If you have a combi supply please use a pressure reducing valve if required to lower the BAR pressure to the shower Please Remember that this product is free standing and is designed to be pulled away from the wall Th...

Страница 10: ...www insigniarange com Last Modified 03 04 2018 10 ...

Страница 11: ...you have the need to replace anything Take the shower tub and remove all the protective wrapping and fit the waste In the side of the waste supplied in the optional fitting kit you will notice a spigot not seen on an ordinary waste In most cases this is blanked yet should you have a steam version you need to gently drill this out as this item is for the steam generator drainage and will be connect...

Страница 12: ...ights maybe pre fitted to the front fixed glass see above to the curved rails using the ST35 screws The end with the groove is designed to sit on the tray with the flat end connecting to the roof Please note the U shaped channel is meant to face inwards to allow the glass to fit correctly wider rail with Insignia logo at the top PLEASE NOTE The screw head needs to bypass the OUTER hole If this doe...

Страница 13: ...2018 13 Step 4 Now attach your inner uprights to your front fixed glass panels by inserting these over the thin rubber seals as shown by the arrows in the image please note that the front uprights will need a pilot hole drilled before screwing ...

Страница 14: ...s for the top and ST20 screws for the bottom There are two screws on each side please note that the front uprights will need a pilot hole drilled before screwing Step 6 Now meet the front of the shower with the back panels and screw together using the ST12 and SW9 washers screws You will need to align the panels and then use the drill piece to create pilot holes for the screws then continue to run...

Страница 15: ...es Step 8 Fit the adjustable wheels to the top and bottom of the glass doors and ensure the wheels are at their lowest position and hang on the inner curved rails with the wheels facing the outside of the glass Once all wheels are fitted and on the rails you can adjust the wheels by turning the plastic bolt clockwise in which in turn will pull the wheels towards the track ensuring a secure a tight...

Страница 16: ...e Note Ensure all backing film on the rear of the glass panels are pierced through the existing glass holes with a knife to provide an efficient smooth fitting and location of the accessories We recommend using a screwdriver on the smaller holes Hand Shower Attach the chrome riser bar to the glass wall ensuring the water inlet is inserted through the lower large hole and hand tightened from the re...

Страница 17: ...ave one for each end of the hose Attach the grey hose from your valve to the inner black tube using PTFE tape please note this only needs to be hand tight Over tightening will snap damage the inner black tube Handle Ensuring that the inner thread is protruding out from the handle far enough place the handle on the outside of the door and secure by tightening the inner chrome knob to the protruding...

Страница 18: ...iffer from the image Please refer to your outer chrome faceplate inside your Insignia shower as a reference point IF YOUR DIAL DOES NOT CORRESPOND TO THE APPROPRIATE DEVICE Turn on your water to the shower and note which output the water exits from then turn off the water and swap over the relevant hose Alternatively remove the outer chrome knob by removing the chrome cap and loosening the grub sc...

Страница 19: ...www insigniarange com Last Modified 03 04 2018 19 Electric Box Connections Connect the cables below to the corresponding devices on the shower Antenna Speaker Speaker Roof Light ...

Страница 20: ...rom one side and going around to the back and then to the other side finishing at the front If you have a small leak normally caused through insufficient sealer or air bubble on assembly dry the area thoroughly and reseal Please remember the location of the water may not be exactly where the leak is as it could have run around to a low point Never seal your inner fittings unless necessary remember...

Страница 21: ...utton 4 5 Audio Volume Press to either turn up or down the radio volume Button 6 Padlock On Off Hold in for three to five seconds to unlock the automatically locking control panel Button 8 Power Button On Off PLEASE NOTE When the Control Panel is locked none of the buttons will work with the exception of the Padlock button which will unlock the control panel To see our tutorial videos for operatin...

Страница 22: ...www insigniarange com Last Modified 03 04 2018 22 Need Help If so then simply download Insignia s free comprehensive help and troubleshooting brochure now Simply visit www insigniarange co uk help aspx ...

Страница 23: ...h Button Wheel Twin Chrome Wheel Internal Items Part Code Part Description SP300 Waste hose SP187 Drain Hose SP211 Transformer SP308 Magnetic door seals SP166 Approximately 4 meters SP310 Rear door seals SP115 3 port 2 feed non thermo valve SP193 3 Port Selector Cartridge SP091 Non Thermostatic Tap Cartridge External Items Parts List Part Code Part Description INS003 6 Bottom Rail INS003 5 Top rai...

Страница 24: ...e used in any way shape or form with out written permission from Maclean International Ltd Images are NOT permitted to be saved printed or uploaded Violation of copyright laws are punishable by law All images are registered with ImageTraker Insignia is a registered trademark of Maclean International Ltd ...

Отзывы: