We recommend a BAR pressure between 2.5 and 3.4 BAR. If
you have a combi boiler system no problem should be
experienced. If you have a gravity feed older type installation
(hot water tank type usually less than 1 BAR) you will almost
certainly need a pump. We cannot advise on which type of
pump is used, location or design because all house plumbing
layouts vary. This is a job for your installer/plumber. The end
delivery however must fall within the scope above.
Important Note
Do not exceed 3.4 BAR pressure under any
circumstances. Warranty is void if so as damage will occur. If
you have a combi supply, please use a pressure reducing valve
if required to lower the BAR pressure to the shower.
Please Remember that this product is free standing and is
designed to be pulled away from the wall.
The waste hose must be of a flexible type
(1m flexible waste
supplied).
The water supply pipes need to be at least 1 metre in length
and must be that of a flexible braided type
(not supplied).
DO NOT OVERTIGHTEN THE BRAIDED HOSES AS IT CAN CAUSE
THE CONNECTION TO POP AFTER A FEW WEEKS OF USE.
Always fit easy to get to isolation taps on both hot and cold
water supply (not supplied). Just like a dishwasher or washing
machine, this product
MUST
be isolated when not in use.
You will require:
•
Scissors
•
Knife
•
Spirit Level
•
Tape Measure
•
Philips Screwdriver
•
Electric Drill
•
Safety Gloves
•
Safety Glasses
Pressure/Water Requirements
Tools Required
•
RubberGum (supplied)
•
Plumbers Mait (not supplied)
•
Hot and cold isolation valves (not supplied)
•
2 x Braided hoses (not supplied)
Steam version
requires 3.
Parts Required
STEAM VERSION
Voltage Rating 220
-
240AC
Frequency Rating 50Hz
Power Rating 3KW
NON
-
STEAM VERSION
Voltage Rating 100
-
240AC
Frequency Rating 50/60Hz
Power Rating 12v DC/1500 mA
Your electrical contractor should understand
ALL
legal
requirements of connection before undertaking any work
or installation.
UNDER NO CIRCUMSTANCES UNDERTAKE THIS
YOURSELF!!!
Note for electrician: This product comes with 13 amp plug
(s) fitted with an RCD unit
(steam version only)
. We leave it
this way for you to connect it your own way due to
continued additions to current regulations.
1) Connect within current laws and IP directives.
2) (Preferred) Wire into isolated fused feed connecting
directly to the house consumer/service box.
Always use protection against electrical surge. Your shower
should be treated the same as a home computer. A surge
protector should eradicate the possibility of either the
transformer or control panel being burnt out.
Electrical work needs to be signed off by a fully qualified
operative by law. Failure to adhere to this will not only void
your electrical warranty for your shower, but could void
your house insurance too.
Electrical Requirements